DR4018 DIGISWITCH (v1.2)
www.digirails.com Page 8
Signal function mapping output (EXPERT)
This table shows how the different signal numbers are coupled to output groups. It can be useful to change this
configuration when you want to control both signals and points with the same module.
CV
OUTPUTS
1 –4
5—8
9-12
13-16
SIGNAL 1
143
1
2
4
8
SIGNAL 2
167
1
2
4
8
SIGNAL 3
191
1
2
4
8
SIGNAL 4
215
1
2
4
8
Output pulse times
Use these CVs to configure the pulse duration for outputs 1 through 16 provided they are set to pulse CV113=7
and CV47=13.
Pulsed outputs are automatically activated by choosing preset 0 or 3 in CV47
CV
CV Definition
Range
Value
238 Pulse time OUTPUT 1
0-255
128
239 Pulse time OUTPUT 2
0-255
128
240 Pulse time OUTPUT 3
0-255
128
241 Pulse time OUTPUT 4
0-255
128
242 Pulse time OUTPUT 5
0-255
128
243 Pulse time OUTPUT 6
0-255
128
244 Pulse time OUTPUT 7
0-255
128
245 Pulse time OUTPUT 8
0-255
128
246 Pulse time OUTPUT 9
0-255
128
247 Pulse time OUTPUT 10
0-255
128
248 Pulse time OUTPUT 11
0-255
128
249 Pulse time OUTPUT 12
0-255
128
250 Pulse time OUTPUT 13
0-255
128
251 Pulse time OUTPUT 14
0-255
128
252 Pulse time OUTPUT 15
0-255
128
253 Pulse time OUTPUT 16
0-255
128
Signal aspects
The combination of the first three addresses determines 1 of 8 possible signal aspects. The fourth address activates (night)
dimming.
R = Red button on your control unit
G = Green button on your control unit
Address
Signal aspect
1
e
2
e
3
e
NS 3 lights with digit board
DB HP DB VR-Combi
DB VR
NMBS
R
R
R
0
Red
HP0
Off
VR0
Red
G
R
R
1
Green
HP1
VR0
VR1
Flashing red
R
G
R
2
Yellow
HP2
VR0
VR2
Double yellow
G
G
R
3
Flashing green with digit
SH1
Off
Off
Flash double yellow
R
R
G
4
Yellow with digit
HP1
VR1
VR0
Green yellow
horiz
.
G
R
G
5
Flashing green
HP2
VR1
VR1
Green
R
G
G
6
Flashing yellow
HP1
VR2
VR2
Flashing green
G
G
G
7
Yellow with flashing digit
HP2
VR2
Off
Green yellow vertical