DigiplexNE DGP-NE96
- 28 -
Programming Guide
r
= Default setting
Dialer Options
r
= Default setting
SECTION [3032] : Partition Options 2
SECTION [3033] : System Options 2
Option
OFF
ON
Option
OFF
ON
[1]
Bell/siren output in partition 1
l
Disabled
r
Enabled
[1]
Multiple actions in user menu
r
Disabled
l
Enabled
[2]
Bell/siren output in partition 2
r
Disabled
l
Enabled
[2]
User code length
r
Fixed
l
Flexible
[3]
Bell/siren output in partition 3
r
Disabled
l
Enabled
[3]
User code length (if option
[2]
OFF)
r
4-digits
l
6-digits
[4]
Bell/siren output in partition 4
r
Disabled
l
Enabled
[4]
Power save mode
l
Disabled
r
Enabled
[5]
Bell/siren output in partition 5
r
Disabled
l
Enabled
[5]
Bypass not displayed while system
is armed
l
Disabled
r
Enabled
[6]
Bell/siren output in partition 6
r
Disabled
l
Enabled
[6]
Future Use
l
N/A
l
N/A
[7]
Bell/siren output in partition 7
r
Disabled
l
Enabled
[7]
EOL resistor on hardwire zones
r
Disabled
l
Enabled
[8]
Bell/siren output in partition 8
r
Disabled
l
Enabled
[8]
(ATZ) Zone Doubling
r
Disabled
l
Enabled
SECTION [3034] : System Options 3
SECTION [3035] : Restrict Arming Options
Option
OFF
ON
Option
OFF
ON
[1]&[2]
Wireless Transmitter Supervision
Options (see table below)
l
See Table
l
See Table
l
See Table
l
See Table
[1]
Restrict arming on AC failure
r
Disabled
l
Enabled
[2]
Restrict arming on battery failure
r
Disabled
l
Enabled
[3]
Generate supervision failure if
detected on a bypassed wireless zone
r
Yes
l
No
[3]
Restrict arming on bell or auxiliary
failure
r
Disabled
l
Enabled
[4]
Restrict arming on a wireless
transmitter supervison failure
r
Disabled
l
Enabled
[4]
Restrict arming on TLM failure
r
Disabled
l
Enabled
[5]&[6]
Zone & Module Tamper Recognition
Options (see table below)
l
See Table
l
See Table
l
See Table
l
See Table
[5]
Restrict arming on module troubles
r
Disabled
l
Enabled
[6]
Future Use
l
N/A
l
N/A
[7]
Generate tamper if detected on
bypass zone
l
Yes
r
No
[7]
Future Use
l
N/A
l
N/A
[8]
Restrict arming on tamper trouble
r
Disabled
l
Enabled
[8]
Serial Port Baud Rate
r
19,200
l
38,400
Wireless Transmitter Supervision Options
(Section [3034]; options
[1]
&
[2]
)
Zone & Module Tamper Recognition Options
(Section [3034]
:
options
[5]
&
[6]
)
[1]
[2]
[5]
[6]
OFF
OFF
-
Disabled
(default)
OFF OFF
-
Disabled
(default)
ON
OFF
- When disarmed:
GENERATES
TROUBLE
ONLY
ON
OFF - When disarmed:
GENERATES
TROUBLE
ONLY
- When armed: Follows
Zone Alarm Types
(page 6)
- When armed: Follows
Zone Alarm Types
(page 6)
OFF
ON
- When disarmed:
GENERATES
SILENT
ALARM
OFF ON
- When disarmed:
GENERATES
SILENT
ALARM
- When armed: Follows
Zone Alarm Types
(page 6)
- When armed: Follows
Zone Alarm Types
(page 6)
ON
ON
- When disarmed:
GENERATES
AUDIBLE
ALARM
ON
ON
- When disarmed:
GENERATES
AUDIBLE
ALARM
- When armed: Follows
Zone Alarm Types
(page 6)
- When armed: Follows
Zone Alarm Types
(page 6)
SECTION [3036]: Dialer Options 1
SECTION [3037] : Dialer Options 2
Option
OFF
ON
Option
OFF
ON
[1]&[2]
Telephone Line Monitoring (TLM) -
(see table on page 29)
l
See Table
l
See Table
l
See Table
l
See Table
[1]
Call back
r
Disabled
l
Enabled
[2]
Automatic event buffer transmission
r
Disabled
l
Enabled
[3]
Dialer (reporting to monitoring
station)
r
Disabled
l
Enabled
[3]&[4]
Hourly test transmission (see table
on page 29)
l
See Table
l
See Table
l
See Table
l
See Table
[4]
Dialing method
l
Pulse
r
Tone
(DTMF)
[5]
Pulse ratio
(E.U. = Europe; N.A. = North America)
l
1:2
(E.U.)
r
1:1.5
(N.A.)
[5]
Keypad beep on successful arming/
disarming report
r
Disabled
l
Enabled
[6]
Busy tone detection
l
Disabled
r
Enabled
[6]
Alternate Dialing
r
Disabled
l
Enabled
[7]
Switch to pulse dialing on 5
th
attempt
r
Disabled
l
Enabled
[7]
Dial Tone Delay (if no dial tone)
r
Force dial
l
Hang-up
[8]
Bell/siren upon communication
failure if system is armed
r
Disabled
l
Enabled
[8]
Report zone restore
ON =
On zone closure;
OFF =
On bell cut-off
l
Disabled
r
Enabled