Digiplex DGP-848 Programming Manual Download Page 38

Digiplex DGP-848  

  

 - 38 - 

    

Programming Guide

CONTACT ID REPORT CODE LIST

If using the Ademco Contact ID format, key in the 2-digit hexadecimal value (PROG. VALUE) to program the desired report 
codes into sections 

[600]

 to 

[718]

.

CID#

Reporting Code

Prog.
Value

CID#

Reporting Code

Prog.

Value

CID#

Reporting Code

Prog.

Value

MEDICAL ALARMS - 100

204

Low Water Level

2F

403

Automatic O/C

5D

100

Medical Alarm

01

205

Pump Activated

30

404

Late to O/C

5E

101

Pendant Transmitter

02

206

Pump Failure

31

405

Deferred

5F

102

Fail to Report In

03

SYSTEM TROUBLES - 300 & 310

406

Cancel

60

FIRE ALARMS - 110

300

System Trouble

32

407

Remote Arm/Disarm

61

110

Fire Alarm

04

301

AC Loss

33

408

Quick Arm

62

111

Smoke

05

302

Low System Battery

34

409

Keyswitch O/C

63

112

Combustion

06

303

RAM Checksum Bad

35

REMOTE ACCESS - 410

113

Water Flow

07

304

ROM Checksum Bad

36

411

Callback Request Made

64

114

Heat

08

305

System Reset

37

412

Success - Download Access

65

115

Pull Station

09

306

Panel Program Changed

38

413

Unsuccessful Access

66

116

Duct

0A

307

Self-Test Failure

39

414

System Shutdown

67

117

Flame

0B

308

System Shutdown

3A

415

Dialer Shutdown

68

118

Near Alarm

0C

309

Battery Test Failure

3B

ACCESS CONTROL - 420

PANIC ALARMS - 120

310

Ground Fault

3C

421

Access Denied

69

120

Panic Alarm

0D

SOUNDER/RELAY TROUBLES - 320

422

Access Report By User

6A

121

Duress

0E

320

Sounder Relay

3D

SOUNDER RELAY DISABLES - 520

122

Silent

0F

321

Bell 1

3E

520

Sounder/Relay Disabled

6B

123

Audible

10

322

Bell 2

3F

521

Bell 1 Disable

6C

BURGLAR ALARMS - 130

323

Alarm Relay

40

522

Bell 2 Disable

6D

130

Burglary

11

324

Trouble Relay

41

523

Alarm Relay Disable

6E

131

Perimeter

12

325

Reversing

42

524

Trouble Relay Disable

6F

132

Interior

13

SYSTEM PERIPHERAL TROUBLES - 330 & 340

525

Reversing Relay Disable

70

133

24-Hour

14

330

System Peripheral

43

COMMUNICATION DISABLES - 550 & 560

134

Entry/Exit

15

331

Polling Loop Open

44

551

Dialer Disabled

71

135

Day/Night

16

332

Polling Loop Short

45

552

Radio xmitter Disabled

72

136

Outdoor

17

333

Exp. Module Failure

46

BYPASSES - 570

137

Tamper

18

334

Repeater Failure

47

570

Zone Bypass

73

138

Near Alarm

19

335

Local Printer Paper Out

48

571

Fire Bypass

74

GENERAL ALARMS - 140

336

Local Printer Failure

49

572

24-Hour Zone Bypass

75

140

General Alarm

1A

COMMUNICATION TROUBLES - 350 & 360

573

Burg. Bypass

76

141

Polling Loop Open

1B

350

Communication 

4A

574

Group Bypass

77

142

Polling Loop Short

1C

351

Telco Fault 1

4B

TEST/MISC. - 600

143

Expansion Module Failure

1D

352

Telco Fault 2

4C

601

Manual Trigger Test

78

144

Sensor Tamper

1E

353

Long Range Radio

4D

602

Periodic Test Report

79

145

Expansion Module Tamper

1F

354

Fail to Communicate

4E

603

Periodic RF Xmission

7A

24-HOUR NON-BURGLARY - 150 & 160

355

Loss of Radio Supervision

4F

604

Fire Test

7B

150

24-Hour Non-Burglary

20

356

Loss of Central Polling

50

605

Status Report to Follow

7C

151

Gas Detected

21

PROTECTION LOOP TROUBLES - 370

606

Listen-in to Follow

7D

152

Refrigeration

22

370

Protection Loop

51

607

Walk Test Mode

7E

153

Loss of Heat

23

371

Protection Loop Open

52

621

Event Log Reset

7F

154

Water Leakage

24

372

Protection Loop short

53

622

Event Log 50% Full

80

155

Foil Break

25

373

Fire Trouble

54

623

Event Log 90% Full

81

156

Day Trouble

26

SENSOR TROUBLES - 380

624

Event Log Overflow

82

157

Low Bottled Gas Level

27

380

Sensor Trouble

55

625

Time/Date Reset

83

158

High Temp

28

381

Loss of Super. -RF

56

626

Time/Date Inaccurate

84

159

Low Temp

29

382

Loss of Super. - RPM

57

627

Program Mode Entry

85

161

Loss of Air Flow

2A

383

Sensor Tamper

58

628

Program Mode Exit

86

FIRE SUPERVISORY - 200 & 210

384

RF xmtr. Low Battery

59

631

Exception Schedule Change

87

200

Fire Supervisory

2B

OPEN/CLOSE - 400

201

Low Water Pressure

2C

400

Open/Close

5A

202

Low CO2

2D

401

O/C by User

5B

203

Gate Valve Sensor

2E

402

Group O/C

5C

Summary of Contents for DGP-848

Page 1: ...CIMAL AND HEXADECIMAL PROGRAMMING TABLE Certain sections may require the entry of one or more Hexadecimal values from 0 to F For LCD keypads For Grafica keypads 0 to 9 values 0 to 9 respectively DISAR...

Page 2: ...Partition 2 Options 21 Partition 3 Options 22 Partition 4 Options 23 Dialer Options 24 Partition 1 Event Call Direction 25 Partition 2 Event Call Direction 26 Partition 3 Event Call Direction 27 Parti...

Page 3: ..._________ ___________ 32 ________________________ ___________ 10 ________________________ ___________ 33 ________________________ ___________ 11 ________________________ ___________ 34 _______________...

Page 4: ...___________________ ___________ 83 ________________________ ___________ 59 ________________________ ___________ 84 ________________________ ___________ 60 ________________________ ___________ 85 _____...

Page 5: ..._ __ __ __ __ __ __ __ 112 ___ ___ 1 2 3 4 5 6 7 8 When option 7 in section 502 is enabled for PGM1 to act as a zone input for two wire smoke detectors the control panel will recognize PGM1 as input n...

Page 6: ..._____ 023 __ __ __ __ __ __ __ __ __ __ __ 123 ___ ___ 1 2 3 4 5 6 7 8 24 ________________ __________ 024 __ __ __ __ __ __ __ __ __ __ __ 124 ___ ___ 1 2 3 4 5 6 7 8 25 ________________ __________ 02...

Page 7: ...____ __________ 039 __ __ __ __ __ __ __ __ __ __ __ 139 ___ ___ 1 2 3 4 5 6 7 8 40 ________________ __________ 040 __ __ __ __ __ __ __ __ __ __ __ 140 ___ ___ 1 2 3 4 5 6 7 8 41 ________________ ___...

Page 8: ...__ __ 155 ___ ___ 14 5 6 7 8 8 _______________ __________ 056 __ __ __ __ __ __ __ __ __ __ __ 156 ___ ___ 14 5 6 7 8 Sections 049 to 056 represent keyswitches 1 to 8 respectively This feature tells...

Page 9: ...INPUT SPEED 015 PANEL DOUBLER 7 600 msec 216 ___ ___ ___ x 20 msec INPUT SPEED 016 PANEL DOUBLER 8 600 msec 217 ___ ___ ___ max 15 AUTO ZONE SHUTDOWN Disabled 218 ___ ___ ___ max 15 AUTO TROUBLE SHUTD...

Page 10: ..._ ___ see section 503 PGM1 DELAY 5 sec 251 ___ ___ ___ see section 503 PGM2 DELAY 5 sec 252 ___ ___ ___ see section 503 PGM3 DELAY 5 sec 253 ___ ___ ___ see section 503 PGM4 DELAY 5 sec 254 ___ ___ __...

Page 11: ...__________________________ __ __ __ __ __ __ __ __ 314 14 ____________________________________________ __ __ __ __ __ __ __ __ 315 15 ____________________________________________ __ __ __ __ __ __ __...

Page 12: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 344 04 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 345 05 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6...

Page 13: ..._ ___ ___ 1 2 3 4 5 6 7 8 Interval B ___ ___ ___ ___ ___ ___ ___ ___ 1 2 3 4 5 6 7 8 373 13 Interval A ___ ___ ___ ___ ___ ___ ___ ___ 1 2 3 4 5 6 7 8 Interval B ___ ___ ___ ___ ___ ___ ___ ___ 1 2 3...

Page 14: ...OFF the PGM will activate deactivate whenever a user between 1 and 8 arms the system Section PGM Event Group First Digit Event Group Second Digit Event Selection on off 400 PGM1 Activation Event ___ _...

Page 15: ...Door 09 Door 10 Door 11 Door 12 Door 13 Door 14 Door 15 Door 16 2 Door 17 Door 18 Door 19 Door 20 Door 21 Door 22 Door 23 Door 24 3 Door 25 Door 26 Door 27 Door 28 Door 29 Door 30 Door 31 Door 32 9 Us...

Page 16: ...01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zone 07 Zone 08 1 Zone 09 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 2 Zone 17 Zone 18 Zone 19 Zone 20 Zone 21 Zone 22 Zone 23 Zone 24 3 Zone 2...

Page 17: ...__ __ __ __ __ __ __ __ __ __ __ __ 460 Zone 10 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 484 Zone 34 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 461 Zone 11 __ __ __ __ __ __ __ __ __ __ __...

Page 18: ...ns Option OFF ON 1 PGM 1 Deactivation Type N Follows Event N Follows Timer 2 PGM 2 Deactivation Type N Follows Event N Follows Timer 3 PGM 3 Deactivation Type N Follows Event N Follows Timer 4 PGM 4 D...

Page 19: ...ot appear in Trouble Display N Disabled N Enabled 8 Restrict arming on battery AC failure N Disabled N Enabled SECTION 504 Keypad Other Options Option OFF ON 1 Multiple Actions in User Menu N Disabled...

Page 20: ...Alarm 6 Panic 3 alarm type N Report Only N Fire Alarm 7 Report Disarming Options N Always report disarming N Report disarming only after alarm 8 Always Force Arm When Regular Arming N Disabled N Enab...

Page 21: ...Alarm 6 Panic 3 alarm type N Report Only N Fire Alarm 7 Report Disarming Options N Always report disarming N Report disarming only after alarm 8 Always Force Arm When Regular Arming N Disabled N Enab...

Page 22: ...Alarm 6 Panic 3 alarm type N Report Only N Fire Alarm 7 Report Disarming Options N Always report disarming N Report disarming only after alarm 8 Always Force Arm When Regular Arming N Disabled N Enab...

Page 23: ...Alarm 6 Panic 3 alarm type N Report Only N Fire Alarm 7 Report Disarming Options N Always report disarming N Report disarming only after alarm 8 Always Force Arm When Regular Arming N Disabled N Enab...

Page 24: ...tion Failure if system is armed N Disabled N Enabled SECTION 522 Dialer Options Option OFF ON 1 Call Back N Disabled N Enabled 2 Automatic Event Buffer Transmission N Disabled N Enabled 3 Hourly Test...

Page 25: ...led N Enabled 2 Call Telephone Number 2 see section 562 N Disabled N Enabled 3 Call Telephone Number 3 see section 563 N Disabled N Enabled 4 Call Telephone Number 4 see section 564 N Disabled N Enabl...

Page 26: ...led N Enabled 2 Call Telephone Number 2 see section 562 N Disabled N Enabled 3 Call Telephone Number 3 see section 563 N Disabled N Enabled 4 Call Telephone Number 4 see section 564 N Disabled N Enabl...

Page 27: ...led N Enabled 2 Call Telephone Number 2 see section 562 N Disabled N Enabled 3 Call Telephone Number 3 see section 563 N Disabled N Enabled 4 Call Telephone Number 4 see section 564 N Disabled N Enabl...

Page 28: ...led N Enabled 2 Call Telephone Number 2 see section 562 N Disabled N Enabled 3 Call Telephone Number 3 see section 563 N Disabled N Enabled 4 Call Telephone Number 4 see section 564 N Disabled N Enabl...

Page 29: ...ber 1 see section 561 N Disabled N Enabled 2 Call Telephone Number 2 see section 562 N Disabled N Enabled 3 Call Telephone Number 3 see section 563 N Disabled N Enabled 4 Call Telephone Number 4 see s...

Page 30: ...PASSWORD FOR WINLOAD SOFTWARE 560 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ PC TELEPHONE NUMBER FOR WINLOAD SOFTWARE press ENTER if less than 32 d...

Page 31: ...Access code 23 __ __ Access code 24 606 __ __ Access code 25 __ __ Access code 26 __ __ Access code 27 __ __ Access code 28 607 __ __ Access code 29 __ __ Access code 30 __ __ Access code 31 __ __ Ac...

Page 32: ...ss code 35 __ __ Access code 36 637 __ __ Access code 37 __ __ Access code 38 __ __ Access code 39 __ __ Access code 40 638 __ __ Access code 41 __ __ Access code 42 __ __ Access code 43 __ __ Access...

Page 33: ...__ Zone 34 __ __ Zone 35 __ __ Zone 36 664 __ __ Zone 37 __ __ Zone 38 __ __ Zone 39 __ __ Zone 40 665 __ __ Zone 41 __ __ Zone 42 __ __ Zone 43 __ __ Zone 44 666 __ __ Zone 45 __ __ Zone 46 __ __ Zo...

Page 34: ...__ __ Zone 40 691 __ __ Zone 41 __ __ Zone 42 __ __ Zone 43 __ __ Zone 44 692 __ __ Zone 45 __ __ Zone 46 __ __ Zone 47 __ __ Zone 48 693 __ __ Zone 1 __ __ Zone 2 __ __ Zone 3 __ __ Zone 4 694 __ __...

Page 35: ...Fault __ __ Module tamper __ __ Module ROM check error __ __ Module TLM Fail 709 __ __ Module fail to com __ __ Printer fault __ __ Module AC failure __ __ Module battery failure 710 __ __ Module aux...

Page 36: ...CE Closing Extend Disarm with PC software 1 4A7 Remote arm disarm OP Opening Report Disarm after an alarm with PC software 1 4A7 Remote arm disarm OR Disarm From Alarm Quick disarm 1 408 Quick disarm...

Page 37: ...Expansion Restoral Module tamper restore 3 145 Expansion module tamper restore TR Tamper Restoral Module ROM_RAM_error restore 3 3A4 Rom checksum bad restore YG Parameter Changed Module TLM restore 3...

Page 38: ...ripheral 43 COMMUNICATION DISABLES 550 560 134 Entry Exit 15 331 Polling Loop Open 44 551 Dialer Disabled 71 135 Day Night 16 332 Polling Loop Short 45 552 Radio xmitter Disabled 72 136 Outdoor 17 333...

Page 39: ...ss the S key Set desired options Set desired options Set desired options Where sections 801 to 896 represent User s 01 to 96 USER CODE OPTIONS 1 2 Feature off Master Feature Disabled on off User can p...

Page 40: ...power from the control panel 951 Module Reset Reset a module s programmed contents to default by entering its serial number 952 Locate Unlocate Module Locate a specific module e g detector zone expand...

Page 41: ...g this section will reset all Zone and Keyswitch programming sections from 001 to 056 and 101 to 156 to default values 976 Entering this section will reset the following sections to default values 200...

Page 42: ...DGP2 ZX1 _______ X 15PU __________ PU 4 Zone Expansion Modules APR3 ZX4 _______ X 20PU __________ PU 8 Zone Expansion Modules APR3 ZX8 _______ X 40PU __________ PU Omnia Wireless Expansion Modules OM...

Page 43: ...Digiplex DGP 848 43 Programming Guide Hardware Connections SINGLE ZONE INPUTS ATZ DOUBLE ZONE INPUTS...

Page 44: ...aving the shield at the other end of the cable open floating Across Separate Buildings Strip the outer jacket at one end of the shielded cable to expose the shield In the same building that houses the...

Page 45: ...to the system Warning During power up the panel will perform a module scan that lasts between 30 and 120 seconds AUX POWER Refer to transformer requirements below for Auxiliary Power Output Also refe...

Page 46: ...Digiplex DGP 848 46 Programming Guide Notes...

Page 47: ...Digiplex DGP 848 47 Programming Guide...

Page 48: ...R 1 AC Failure 4 Bell Current Limit 2 Battery Trouble 5 Bell Absent 3 Aux Current Limit 6 ROM Check Error 1 TLM 4 Fail to Com 3 2 Fail to Com 1 5 Fail to Com 4 3 Fail to Com 2 6 Fail to Com PC TROUBLE...

Reviews: