Summary of Contents for DGR100

Page 1: ...Single Channel Digital Video Recorder Models DGR100 DGR101 Installation User Manual Digimerge Technologies Inc...

Page 2: ...onment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicatio...

Page 3: ...ng System to Factory Defaults 11 Other Menu Options 12 Timer Recording Setup 12 Record Settings 12 Alarm Setup 13 Remote Protocol Setup 13 Event Log Viewing 14 System Operation 15 On Screen Display OS...

Page 4: ...should be operated using only the power source from standard package Unauthorized repair or parts substitutions may result in fire electric shock or other hazards Do not switch the Power On Off within...

Page 5: ...the need to replace video tapes To learn more about Digimerge products please visit our website at www digimerge com Features Up to 45 Hour Real Time 2755 Hour Time Lapse Recording with 120 GB HDD Mul...

Page 6: ...electrical outlet A Red LED indicator light will be ON to indicate that the DVR is in Standby mode 3 Press the Power button The POWER LED will turn from red to orange and other red LED indicators will...

Page 7: ...STOP i Pressing STOP terminates recording or playing The DVR returns to live monitoring mode and stops all other actions ii In Menu mode the button is used to scroll Down through options 7 REC Press R...

Page 8: ...e Red LED Light is ON 1 HDD blinks on startup after HDD is activated 2 HDD Full HDD has reached its capacity in memory 3 ALARM LED blinks during an alarm remains ON when Alarm feature is set to Enable...

Page 9: ...and mode of recording Alarm Programs Alarm duration and recording during an Alarm Remote Chooses interface for remote protocol via computer System Sets the date chooses an HDD overwrite setting change...

Page 10: ...the Hard Drive Overwrite Use this option to select whether recording will stop when the hard disk is full or whether it will start writing over previous recordings 1 On the System screen press or to...

Page 11: ...nfirm the current operation Selecting the Time Date Display Format 1 On the System screen press or to select Date Display then press ENTER 2 Press or to choose a display format Options are Y M D Year...

Page 12: ...eld on the System screen or press MENU to exit this screen and confirm the current operation Resetting System to Factory Defaults Using the System Reset option will set all options back to factory def...

Page 13: ...quality and speed of recordings Pressing ENTER after scrolling to the Record option will bring up the following menu options Record IPS Set the system to 60 Images Per Second to record in real time O...

Page 14: ...ording during an Alarm The default setting is Field Remote Protocol Setup If wishing to control the DVR remotely from a PC over an RS 232 RS 485 connection this setup menu will allow you to set the ba...

Page 15: ...of 3 incidents occur a loss in Power a loss in Video or a HDD error This submenu displays a list of Events that disabled recording in order of their occurrence by Time and Date PWR The time that Power...

Page 16: ...The available recording options are as follows 1 Manual Recording This is activated by pressing the REC button on the front of the unit Manual recording will override timed recording 2 Timer Recordin...

Page 17: ...n to slow the speed to 1 4X Continue to press FF to slow down the speed The minimum slow speed is 1 32X Slow reverse Press PLAY on the front panel then press SLOW for slow forward Press REW to play im...

Page 18: ...you can Lock the buttons on your DVR Locking disables the buttons and prevents other people from using the system Press ENTER and MENU at the same time to enable Key Lock Press ENTER and MENU at the...

Page 19: ...e that the camera is receiving power No video Check that Timer Alarm Enable is set to YES Timer Alarm recording isn t working Check if the system is in Key Lock mode Press MENU and ENTER at the same t...

Page 20: ...otected VIDEO INPUT 1 video input composite 1 Vp p 75ohm BNC VIDEO OUTPUT 1 video output composite 1 Vp p 75ohm BNC VIDEO RESOLUTION 720 x 486 VIDEO COMPRESSION Wavelet DISPLAY REFRESH RATE 60 ips NTS...

Page 21: ...nd pull towards you The Cartridge Casing will slide out of the DVR NOTE YOU MAY FIND THAT THE CARTRIDGE CASING IS LOCKED IN THIS CASE SKIP AHEAD TO STEP 7 TO FIND INSTRUCTIONS ON UNLOCKING THE CABINET...

Page 22: ...CS Cable Select Please refer to the label on the HDD for the correct settings as these will vary dependant upon model and manufacturer 4 Secure the HDD in the Casing optional Insert the six supplied...

Page 23: ...Cartridge Casing into the DVR 7 Lock the Cabinet Lock the cabinet by inserting the supplied key and turning clockwise NOTE IF YOU DO NOT LOCK THE CABINET THE DVR SYSTEM WILL NOT FUNCTION PROPERLY A l...

Page 24: ...nections The diagrams below show examples of typical configurations where the following additional equipment may be used Single Video Camera Multiple video cameras using a multiplexer Monitor Motion a...

Page 25: ...models The included alarm block not shown allows for easier connections when using external triggers and alarm sensors Below are line diagrams of the alarm block and possible RS 232 connections Appen...

Page 26: ...will stop recording PIN 7 EXTERNAL ALARM NC Normally Closed Under normal operation NC is connected with COM When an alarm is triggered COM disconnects with NC becomes open for the duration of the alar...

Page 27: ...5 184 5 346 5 694 5 1389 2775 Expected Times based on a 80 GB HDD IPS 60 30 15 8 4 2 1 Best 9 18 37 69 138 277 555 High 12 24 49 92 185 370 740 Normal 18 37 74 138 277 554 1108 Record Quality Basic 30...

Page 28: ...27 Digimerge Technologies Inc 300 Alden Road Markham Ontario L3R 4C1 www digimerge com rev04...