Phone: 707 766 6000
www.digilock.com | [email protected]
DCK1-ATV1
Keypad Cam Locks Advanced Security
Shared Use
Product Guide
Programming Instructions
New locks operate only with
= `
.
Locks must be setup to allow full operation.
Initial Setup
a.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
b.
Touch each Manager Key to the key slot. A two-tone beep will be heard for each Manager Key that is
successfully registered.
c.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
d.
Repeat above steps for each lock or follow Express Register instructions to setup all locks.
Up to 25 Manager Keys may be registered to a lock. If required, contact your Digilock Product Representative to order additional
Manager Key(s).
a.
Go to a lock requiring Manager Key(s).
b.
Press
= ` 55 `
. The LED will start to flash.
c.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
d.
Touch each Manager Key to the key slot. A two-tone beep will be heard for each Manager Key that is
successfully registered.
e.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
f.
Repeat above steps for each lock or follow Express Register instructions to register the same Manager Key(s) to
multiple locks.
Register/Add Manager Key(s)
Manager Key(s) can be quickly registered to multiple locks. The Programming Key copies the registered Manager Key(s) from one
lock to multiple locks.
Express Register
a.
Go to the lock registered with the Manager Key(s).
b.
Press
= ` 66 `
. The LED will start to flash.
c.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
d.
At each lock to be registered, touch the Programming Key to the key slot until a two-tone beep is heard and the LED
flashes once to indicate successful registration.
e.
End express registration.* Go to any registered lock and press
= `
then touch the Programming Key to the key
slot to operate the lock.
*The Programming Key will continue to function in express registration mode until it is used to operate a lock.