8. Troubleshooting
Problem
Possible causes
Action
dFlow
does not turn on
Equipment is not receiving
power
from
the
AC
network or circuit breaker
turned off.
Check circuit breaker and
power grid.
Door does not move upon
turning equipment on
Drive cables or motor
c o m m u n i c a t i o n
disconnected.
Check cable connection
between motor and motor
drive board.
Pictograms do not turn
on.
Pictogram Transmitter:
Cable
between
CPU
and Pictogram may be
disconnected.
Pictogram Receiver:
Connection cable between
the pieces of equipment
disconnected.
Check cable connections
on the side according to
the pictogram presenting
a problem.
LED’s do not turn on
LED ribbon power cord
disconnected.
Connection cable between
the pieces of equipment
disconnected.
Check
power
cable
connections
and
LED
communication.
Sensor does not turn on /
does not communicate
AC
power
cord
of
camera
disconnected.
Communication
cable
disconnected.
Check if the camera’s AC
connection is properly
connected
to
dFlow
’s
terminal.
Check if the camera’s
communication cable is
connected
to
dFlow
’s
CPU.
WARNING
To reduce risk of electric shock, before servicing, turn off the
equipment's electrical power by switching the circuit breaker to the
OFF position. Refer all servicing to qualified service personnel only.