background image

16

6.4 Orientation pictogram kit

The orientation pictogram kit also visually signals the direction of passage (green
arrows) or the blocking (red X), but on the front/side part of

.

CATRAX Master

6.5 lectronic counter kit

E

The electronic counter kit of pulses or rotations is digital, has six digits and has been
developed for access control applications that employ Catrax Master turnstiles, and
can also be employed in other projects that require this type of device. The counter is
located in the same place (side slot) as the mechanical counter.
The electronic counter offers inputs for two sensors allowing it to be configured for
sequential sensing, making it possible to detect turnstile rotations in a given
direction. The device is also capable of counting single pulses (as other counters
available on the market).
Digicon electronic counter is operated by means of a single button/key that gives
access to all of its functions. Optionally, a key-operated button can be installed on the
front panel.

.

.

digicon

FRONT

REAR

TECLA

Cn1

Cn2

Cn3

Signal

Name/Description

CN1

1

Ground wire

2

Input sensor 1

3

Input sensor 2

CN2

1

External supply of 5 Vcc (battery eliminator)

2

Ground wire

3

Input for clearance key of frontal key

CN3

1

Ground wire

2

Powered by batteries of 3Vcc (two AA batteries of 1.5 Vcc)

master

Summary of Contents for catrax master

Page 1: ...1 Product Manual master...

Page 2: ...2...

Page 3: ...lated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon S A Code 069 31 251 English Version...

Page 4: ...s 6 7 2 Outputs 6 7 2 1 Return signals 6 5 2 2 Electromagnets 6 7 2 3 Sound alarm 6 7 2 4 Connection scheme 6 7 2 5 Pictogram 6 7 2 6 Pictrogram connections 6 7 3 Configuration od control board Switch...

Page 5: ...omething Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremely pro...

Page 6: ...in this manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is protected by copyri...

Page 7: ...rds Moreover the clients according to their needs can add additional holes Access to the mounting rack is done through a key with secret whose removal and insertion are extremely easy A plastic cover...

Page 8: ...quipment will allow the turning of the arm of After half of the turning is complete 60 degrees a 400 CATRAX Master milliseconds returning signal will be sent informing the passage direction After the...

Page 9: ...all Digicon packages ATTENTION To avoid losses the screws and the wrenches used for assembling the are attached to the box containing the CATRAX Master arms Before discarding the packing materials ca...

Page 10: ...ensions see item 8 Technical characteristics 6 If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M P A concrete or equivalent Once you observe these recommendations procee...

Page 11: ...lling the floor and installing the column it is possible to assemble the arms as shown below INFORMATION The cover to access the screws is open closed by pressure fitting To assemble the arms use an A...

Page 12: ...s for opening CATRAX Master after assembly 1 Unlock the two extremities of the using the key provided CATRAX Master alongside the product Remove the external covers which are pressed into place The co...

Page 13: ...ipment structure contains a device that maintains the cover in the vertical position see detail 4 The following image shows with all covers open CATRAX Master INFORMATION To access the column door rem...

Page 14: ...AX Master the columns The sheet can be of 6 mm tempered glass 6 mm acrylic or and 1 2 mm stainless steel as the client sees fit Besides closing the rear space the panel allows simple customization wit...

Page 15: ...cards is part of the kit and is positioned under the collecting kit The badge reader is not part of the kit ATTENTION The power supply has no ground wire connection Grounding is done directly in the...

Page 16: ...tronic counter offers inputs for two sensors allowing it to be configured for sequential sensing making it possible to detect turnstile rotations in a given direction The device is also capable of cou...

Page 17: ...s to distinguish the two tuning directions To configure the counter it is necessary to access the total visualization mode and proceed as shown Sensors The sensors must connect the sensor s input to t...

Page 18: ...w the supply has a short circuit and overheating protection 6 7 Control board CATRAX Master control board was designed to meet most technologies of access control terminals in the market The controlle...

Page 19: ...12Vcc indicative arrows power red wire 9 GND indicative arrows power black wire 10 solenoid of badge collector box 11 solenoid of badge collector box 12 Sound signal open collector NPN CN3 SERIAL RS 4...

Page 20: ...ted on each side of the equipment X X PIC1 pino 15 PIC2 pino 16 Pictogram 1 Pictogram 2 Open Open GND GND Open GND Open GND X X Particularly about the CN11 connector pins 13 and 14 can be CATRAX Maste...

Page 21: ...normally open contact NO or normally closed contact NC Connect the outputs according to the image below 6 7 2 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposite to the t...

Page 22: ...aximum 500 mA at the moment of activation the GND is sent through a corresponding output 6 7 2 6 Pictogram connections master Sound alarm Maximum current 500mA Inputs Inputs Relay Outputs Acess contro...

Page 23: ...l OFF Enables sound signal in mid turn ON Disables sound signal in mid turn OFF Wait until first turn ON ON Wait for 5 seconds OFF ON Wait for 10 seconds ON OFF Wait for 15 seconds OFF OFF Habilitatio...

Page 24: ...STX Size LSB Size MSB Commands BCC HEXA ASCII FUNCTION 0x48 H Clears direction from right to left 0x41 A t Clears direction from left to right 0x44 D Clears both directions 0x43 C Back to controlling...

Page 25: ...rm raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the el...

Page 26: ...e solenoid the control board has an automatic routine that reduces its voltage to 6Vcc two seconds after the turnstile is turned on One disassembled the arm should be placed manually back into positio...

Page 27: ...crew must be tightened to the maximum to ensure good fixation All three arms must be attached to the same central upper point master 2 Make sure the mini arm s plastic part is fitted in to the steel p...

Page 28: ...e If the mechanism presents any defect request maintenance to a Digicon technician or a qualified company Each inspection should carry out the following operational sequence for each of the three arm...

Page 29: ...8Vcc non obstructed sensors With the pointers at the same position force the equipment s arms to both directions in one of the sides the voltage should be higher than 4 5Vcc Repeat the same operation...

Page 30: ...ctions you must check the lock s correct position check the wear of the lock s fitting in the sprocket Corrective actions 1 if the lock s position is incorrect check the retaining ring and the spring...

Page 31: ...d the equipment to the Technical Assistance Request a replacement for the faulty part or forward the equipment to the Technical Assistance Adjust the electromagnet or forward the equipment to the Tech...

Page 32: ...teristics 8 1 Dimensions 1041 40 984 1041 40 984 1300 51 181 500 19 685 25 0 984 1010 39 763 1116 43 937 972 38 267 657 25 866 425 16 732 INFORMA O The measures presented in this manual are in millime...

Page 33: ...5 A Power supply optional Input 100 Vca a 240 Vca Output 12 0 Vca 5 3 A Dimensions 35 x 51 x 105 mm Distance between holes 43 x 98 mm Diameter of holes 3 5 mm Board with display Power 6 a 24 Vcc 100 m...

Page 34: ...lvent But be careful never scrape the surface of stainless steel with thick blades spatulas or abrasives Rust spots With a cotton swab dipped in water and nitric acid at 10 make topical applications k...

Page 35: ...water If this is not enough to soften burned foods or charred deposits use more aggressive products such as caustic soda removers used in household cleaning TIP Even in the case of stubborn dirt try...

Page 36: ...technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and damage...

Page 37: ...37...

Page 38: ...Castiel 640 Distrito Industrial Gravata 94045 RS CEP 420 Sales 0xx51 3489 8700 3489 8745 Technical assistance 0xx51 3489 8903 Email vendas acesso digicon com br Branch office SP Street S o Paulo 82 A...

Reviews:

Related manuals for catrax master