Gross
weight:

Approx. 45 kg (package included)

Electromagnets’
power

12Vdc / 2A

Power supply

Input: 100 Vac to 240 Vac 60HZ
Output: 24,0 Vcc +/- 5% 4,5 A

Operational
temperature

from 0ºC to 50ºC

Power

Consumption during rotation is 36 W

INFORMATION:

The measures in the images are given in millimeters

34

243

300

510

1042

digicon

Catrax

www.catrax.com.br

Summary of Contents for catrax automatic clip

Page 1: ...Product manual...

Page 2: ......

Page 3: ...d stored in a retrieval system translated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon...

Page 4: ...ems 14 6 1 Collecting box kit 14 6 1 1 Connecting collector kit to control board 15 6 2 Operational pictogram kit 16 6 3 Power suply 17 6 4 Electromechanical counter kit 17 6 5 Control board 18 6 5 1...

Page 5: ...tes something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremel...

Page 6: ...ual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is protected by copyright laws Th...

Page 7: ...e the column CATRAX presents a U shaped internal support mounting rack with Automatic Clip standard holes for the fixation of additional electronic boards Moreover the clients according to their needs...

Page 8: ...Clip After half of the turning is complete 45 degrees a 400 milliseconds returning signal will be sent informing the passage direction After the signal the arm cannot be returned to the previous posi...

Page 9: ...inspection before installing and assembling the turnstile A checklist that works as a guide during inspection accompanies all Digicon packages See below the parts that can compose CATRAX Automatic Cli...

Page 10: ...hor bolts minimum of 4 cm of FCK15 M P A concrete or equivalent ATTENTION To see details on the dimensions of CATRAX Automatic Clip see item 8 technical characteristics 10 To fix the column to the flo...

Page 11: ...con suggests that two people assemble the arms 1 With already unboxed and installed set the arms close to CATRAX Automatic Clip the tube s frontal holes central axis First fit the arm s lower rod and...

Page 12: ...X Automatic Clip equipment can be done with the key that accompanies the equipment in two ways Rear cover and frontal cover open the lock with the key at the rear of CATRAX Automatic Clip CATRAX Autom...

Page 13: ...e turnstile has circuit breakers in its columns where the power cables electrical supply and the ground wire must be connected CAUTION Electric connections must be performed by qualified professionals...

Page 14: ...to the client s needs See the description of each of these items The collecting box kit has a device for collecting retaining and gathering cards or badges It is ideal for places with eventual visito...

Page 15: ...Para placa controle de acesso Sensor utilizado para recolher o cart o ap s 1 5 segundos TIP To obtain information about the collecting box kit s configuration consult item 6 5 Control board 15 Sensor...

Page 16: ...am kit visually signals if the passage is cleared or not through green and red pictograms on CATRAX Automatic Clip s front Passage cleared green Passage blocked red TIP To obtain information on the co...

Page 17: ...nput and output voltages indicated in the image below the supply has a short circuit and overheating protection PHASE NEUTRAL GROUND WIRE GND 24V 3A dc INPUT 100 a 240 Vac OUTPUT 6 4 Electromechanical...

Page 18: ...suited for the CATRAX Automatic Clip s needs and it is one of the best options for the equipment s operation The following images show the control board with its straps connectors and dipswitch as wel...

Page 19: ...node CN7 AUDIO 1 SIGNAL 2 GND CN8 ENTRADAS 1 vext1 enables turn through voltage 2 HAB1 enables turn through dry contact from right to left 3 GND 4 Vext2 enables turn through voltage 5 HAB2 enables tur...

Page 20: ...alongside CATRAX Automatic Clip CN9 OUTPUTS 1 NO or NC Contact HAB1 return 2 Contact C HAB1 return 3 NO or NC Contact HAB2 return 4 Contact C HAB2 return 5 Output for indicative X open collector NPN...

Page 21: ...via relay normally open contact NO or normally closed contact NC Connect the outputs according to the image below 6 5 1 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposi...

Page 22: ...ce signal two short rings is not cleared and is forced during 1 second 1 second rings is stuck mid turn for over 2 seconds 1 second rings Connect the outputs according to the following image 6 5 1 4 C...

Page 23: ...rmally open and without input voltage enabling passage in face of these signals or NC inputs relay or pushbutton contact usually closed and with input voltage enabling passage in the absence of these...

Page 24: ...The switch or dipswitch DS2 allows programming the following actions invitation turning speed passage counting To program DS2 put each pin in the desired position according to the table below CHAVE 1...

Page 25: ...ct with 2 relays Enabling both ways Clockwise and Counter Clockwise with 1 single relay 7654321 U U U U U U U U U U Dry contact Enabling Clockwise Enabling anti Clockwise 7654321 U U U U U Relay Integ...

Page 26: ...Vdc Vdc Vdc 5 24V Integrator s controller board Anti panic drop arm mechanism input Enabling through solid state 10987 U U U U U Integrator s controller 26 Dry contact INFORMATION CCW Counter Clockwis...

Page 27: ...bling through solid state negative Activating through solid state anti panic Drop arm mechanism 1098 Vdc Vdc 5 24V Anti panic 27 54321 Vdc Vdc 5 24V CCW CW Integrator s controller Integrator s control...

Page 28: ...tive Passage confirmation Vcc Rel logic lever SH in disk emulation DIP Ds2 n 7 in mode ON Vdc 4321 Digital positive input U U U U U NA NF Rl2 3 4 NO NC 1 2 Rl1 U U U U U CW CCW 28 98 Vdc 5 24V Vdc Int...

Page 29: ...e pulse Passage confirmation through disk emulation can be set through dip switch Ds2 n 7 in case it s on it ll emulate disk On the other hand it s off it ll general pulse Passage confirmation negativ...

Page 30: ...Electromechanical counter connections 87 Counter Vdc protection diode In case you use inductive counter it will be necessary a protection diode Inductive counter Depends on the couter tension 30...

Page 31: ...ress the electromagnet against the lock s frame so that its area is completely against the electromagnet 3 refasten the screws Set of locks Periodicity every 700 000 cycles To check for the need of co...

Page 32: ...he locking device is maladjusted Adjust the electromagnet or forward the equipment to the Technical Assistance The arm does not remain in the correct position There is wear dirt a broken spring or lac...

Page 33: ...33 8 Technical characteristics 1061 1010 157 1860 300 4 210 R 9 3 0 Dimensions Equipment assembled INFORMATION he arm clip s size can be altered according to the client s T needs...

Page 34: ...wer 12Vdc 2A Power supply Input 100 Vac to 240 Vac 60HZ Output 24 0 Vcc 5 4 5 A Operational temperature from0 C to 50 C Power Consumption during rotation is 36 W INFORMATION The measures in the images...

Page 35: ...or technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and dam...

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ...strial Gravata RS CEP 94045 420 Vendas 0xx51 3489 8700 3489 8745 Assist ncia t cnica 0xx51 3489 8903 Fax 0xx51 3489 1026 E mail vendas acesso digicon com br Branch office SP Rua S o Paulo 82 Alphavill...

Reviews: