background image

HDSL

GENERAL

1.1

1.

GENERAL

1.1. DESCRIPTION

TX

RX

G.703/V35

MASTER

TX

RX

G.703/V35

SLAVE

HDSL line 2/4 wires

R

HIGH SPEED MODEM

K1

K2

/G703 T/SLV

P

 LOC

M REM

 PW

 LIN

 LIN

 V35

 MS

 LOO

 ALM

 AL

HDSL

R

HIGH SPEED MODEM

K1

K2

/G703 T/SLV

P

 LOC

M REM

 PW

 LIN

 LIN

 V35

 MS

 LOO

 AL

M

 AL

HDSL

Picture 1

The connection is carried out using 2 HDSL devices: one placed in the main centre (Master)
and the other one in the remote place (Slave). The Master and Slave devices have different
configurations but are equal as for the electric or mechanic features.
All the digicom’s HDSL modems are supplied with the following factory configuration:

l

Master

l

V.35 selected interface

l

Two wires connection

l

256 Kbit/s line speed

l

Internal clock

1.2. FRONT PANEL VIEW

R

HIGH SPEED MODEM

K1

K2

/G703 T/SLV

P

 LOC

M REM

 PW

 LIN

 LIN

 V35

 MS

 LOO

 ALM

 AL

HDSL

Picture 2

Name

Color

Condition

Function

PWR

Green

Off

No power supply

LINK1

Red

On

Channel 1 Status: Connected with the remote one

Flashing

Channel 1 Status: Searching

LINK2

Red

On

Channel 2 Status: Connected with the remote one

Flashing

Channel 2 Status: Searching

Off

Channel 2 Status: disabled

V35/G703

Red

On

V.35 interface selection

Off

G.703 interface selection

MST/SLV

Red

On

Device configured as Master

Off

Device configured as Slave

LOOP

Red

On

Local Loop enabled

Flashing

Loop enabled on the remote device

ALM LOC

Red

On

Problem with G.703 interface

Flashing

Fault on the local device

ALM REM

Red

On

Problem with the G.703 remote interface (managed
on Master device only)

Flashing

Fault on the remote device

Summary of Contents for HDSL

Page 1: ...http www digicom it User s Guide rev 1 0 05 2000 HDSL...

Page 2: ...CE OF CONFORMITY Digicom S p A via Alessandro Volta 39 21010 Cardano al Campo Varese declares that this product satisfies the basic requirements of Electromagnetic Compatibility and Safety of the belo...

Page 3: ...blems l Objects which produce a strong electtromagnetic field loudspeakers etc l Liquids or chemical corrosive substances To avoid electric shock the equipment should never be opened Ask qualified per...

Page 4: ...wires connection l 256 Kbit s line speed l Internal clock 1 2 FRONT PANEL VIEW R HIGH SPEED MODEM K 1 K 2 G 7 0 3 T S L V P L O C M R E M P W L I N L I N V 3 5 M S L O O A L M A L HDSL Picture 2 Name...

Page 5: ...3 interface setup at 120 ohm or 75 ohm G 703 75 ohm TX G 703 interface 75 ohm coaxial BNC send G 703 75 ohm RX G 703 interface 75 ohm coaxial BNC receive G 703 75 ohm switch Join the shield of coaxial...

Page 6: ...e and the line speed Case Interface Flow Wires Interface line speed A G703 E1 4 Interface speed fixed at 2 Mbit s Speed for each couple of wires 1 Mbit s B G703 E1 2 Interface speed fixed at 2 Mbit s...

Page 7: ...HDSL INSTALLATION 1 2 NOTE For further and complete information on the SetHDSL please refer to the program help on line...

Page 8: ...464 512 8 272 528 576 9 336 592 640 10 336 656 704 11 400 720 768 12 400 784 832 13 464 848 896 14 464 912 960 15 528 976 1024 1Mbps 16 528 1040 1088 17 592 1104 1152 18 592 1168 1216 19 656 1232 128...

Page 9: ...21010 Cardano al Campo VA via A Volta 39...

Reviews: