DigiBird DB-AVCLink User Manual Download Page 40

Software 

37 

 

 

2.

 

Restore the PC configurations. 

Click 

  button > click 

[Please choose a file]

 button in the pop-up 

window > select a file that already stored before > click 

[Upload]

 button to restore 

the configuration. 

 

3.

 

The restore process 

The screen will display a processing page when the system restoring. It is about 2 
minutes to complete.   

 

Summary of Contents for DB-AVCLink

Page 1: ...AV KVM Over Fiber Matrix Switcher User Manual Version 2017 V1...

Page 2: ...IMER 2 INTRODUCTION 3 MATRIX DEVICE 3 FRONT PANEL 3 REAR PANEL 5 SET IP ADDRESS 7 OPTIC TRANSFER UNIT 8 SETUP 10 SOFTWARE 11 LOGIN 11 OVERVIEW 12 DASHBOARD 12 SETTINGS 13 SWITCH 13 KVM 15 SET KVM CHAN...

Page 3: ...US 25 AUDIO CONFIGURATION 26 RESOLUTION 26 ALARM 29 USERS 30 ADD A USER 30 AUTHORITIES 31 EDIT 34 DELETE 34 BACKUP AND RESTORE 35 BACKUP 35 RESTORE 36 UPGRADE 38 FACTORY CONFIGURATION 38 RUNNING RATE...

Page 4: ...ual more clearly Cautions This symbol indicates best practice information to show recommended and appropriate manner to use this product efficiently Warnings The important operating instruction that s...

Page 5: ...mages resulting from the use of the information contained herein The manufacturer reserves the right to change specifications functions or circuitry of the prod uct without notice The manufacturer can...

Page 6: ...sts of Matrix Device and Optic Transfer Unit The chassis sizes are 8U and 26U and the Optic Transfer Unit means Transmitter and Receiver Matrix Device Front Panel 8U chassis 160x ports The front panel...

Page 7: ...Introduction 4...

Page 8: ...irs of dual optical ports to be connected with the receiver Rx CMC Slot The Confidence Monitoring Slot to populate the CMC Confidence Monitoring Card card for local monitoring Control Slot Slot for co...

Page 9: ...Introduction 6 26U chassis 576x ports The 26U chassis includes thirty six 36x input slots thirty six 36x output slots two 2x control slots one 1x CMC slot and two 2x PSU slots...

Page 10: ...Introduction 7 Set IP address Operation OSD...

Page 11: ...Introduction 8 Indicators POWER Power indicator IR IR indicator Reserved for future use RUN RUN indicator illuminate when operating normally Optic Transfer Unit...

Page 12: ...Panel HDMI Transmitter Front Panel Rear Panel HDMI Receiver Front Panel Rear Panel 4K HDMI Transmitter Front Panel Rear Panel 4K HDMI Receiver Front Panel Rear Panel DP Transmitter Front Panel Rear Pa...

Page 13: ...abling problems and start to integrate with your system more efficiently Setup of the matrix 1 Install the I O cards usually be populated well by DigiBird 2 Connect RX and TX to the I O ports 3 Connec...

Page 14: ...ontrol computer and the Matrix must be in the same LAN network under the same domain Open the Chrome and input the IP of the Matrix then press the Enter key The default IP address of the Matrix is 192...

Page 15: ...n enter the dash board logout save scenes refresh system preview configuration and search ports through the filter Input Output Ports Here lists all the Input Output ports you set and the system will...

Page 16: ...pports custom defined When the matrix you use is an 8U chassis you can see the Unconfigured ports in the middle of the page The unconfig ured ports are not connected to the sources or monitors and can...

Page 17: ...hich you want to switch to You can also select all output ports by clicking Select all button on the upper right corner of the Output ports list To cancel a selected port click the port again Click Ca...

Page 18: ...to the RX through the USB cable connect the resources to the TX through the USB cable as well Then you are able to setup via this software Select an input port then the selected output ports will be...

Page 19: ...ected resource that connected to the TX by the KM OSD Press Ctrl Shift Alt I keys on the keyboard that connected to the RX to enable the OSD You are able to switch any resource or enable the KVM 1 Log...

Page 20: ...s Enter key to move the curser to OK button and press Enter key again to login 2 Switch You will enter the SOURCES interface after you login The SOURCES inter face will list all ports online and offli...

Page 21: ...ey again to select one port There are three options press 1 key to enable KVM press 2 key to switch the rsource press 3 key to cancel 3 Quick switch You can press Esc key to return upper menu Press ke...

Page 22: ...f slot the 1 means the sequence number of the port 01 1 means the first port on the 1 input card each card has 8x ports Press Enter key the curser will move to below options KVM to enable KVM to the s...

Page 23: ...e DEV_INFO interface will show you the output resolution resolution mode audio mode serial number and the mac address 5 Help Press Esc key to return the menu bar select HELP option press Enter key The...

Page 24: ...atus Click Preview button to enter the preview interface You can check the current switch ing and KVM status Scene You can configure some frequently used switching relationships and save them as scene...

Page 25: ...then click OK button to confirm If you want to save the current configuration and cover that already saved just need to set the same Scene ID Preview You can preview the scene before recalling it to...

Page 26: ...Rename Right click the scene choose Rename input the Scene Name click OK button to rename Delete Right click the scene choose Delete the Scene click OK button to delete Port Configuration Enter the s...

Page 27: ...input or output automatically according connection with TX input or RX output For example set some unconfigured ports to be input ports Select one or more unconfigured ports Click the circle and drag...

Page 28: ...sts You can drag the pre configured ports back to Unconfigured ports area but the ports that have connected to the TX RX can NOT be moved Rename the Port Select a port double click in the middle area...

Page 29: ...e icon means embedded audio and the means separated audio If you want to set multiple ports at once you can select more ports click button select the audio mode in the pop up window click OK to confir...

Page 30: ...n will be the same with that of input Custom means to set a firmed or customized output resolution no matter how the input resolution is If you select the Custom option you can choose a resolution in...

Page 31: ...Click the Custom Resolution button then you will see the built in resolu tions list Click add button fill in data in the pop up window click OK button to save You can modify or delete the resolutions...

Page 32: ...uide how to solve the problem 1 The alarm in dashboard The wrong connected port will be highlighted with pink and it shows the detail information in the toolbar 2 The alarm in settings There will be a...

Page 33: ...eck or filter the alarm log in the menu of Alarm Users You can add more users and setup different authorities Add a user Click Users in the menu bar Click button to open the add new user window Fill i...

Page 34: ...ccount click button to open the Authority win dow Menu authorities Click Menu button to set the software operating rights For example if you want to prohibit the Config and Users function for the user...

Page 35: ...on to set the input source authorities For example if you do not want the user account to operate the 1 2 and 1 6 input source you should operate as follows Set the Input ports to be Enable Set the 1...

Page 36: ...or menu For example the status of Users is Inherit so it will be Enable when the Setup Menu is Enable and will be Disable when the Setup Menu is Disable 2 Using the user account to login you will see...

Page 37: ...are 34 Edit Choose an account Click button Fill in the new information in the pop up window Click OK button to confirm Delete Choose an account Click button Click OK button in the pop up window to con...

Page 38: ...as backup file to the Matrix or PC in case of losing the configuration The backup can be restored at any time Backup Click the Backup button in the menu bar Click button to backup the hardware and sof...

Page 39: ...ck button to download it to PC The AVCLink is able to backup data every day automatically and keep for 7 net days one time The data on the 1st day will be displaced on the 8th day Restore 1 Restore th...

Page 40: ...Please choose a file button in the pop up window select a file that already stored before click Upload button to restore the configuration 3 The restore process The screen will display a processing pa...

Page 41: ...the System Upgrade button in the menu bar Click Please choose a file button to add a file Click Upload Upgrade button to confirm upgrading Do NOT power off when do the upgrading Factory Configuration...

Page 42: ...orts to transmit video and KM control signal via 2x pcs single mode fiber cables If you don t need to use KM feature you are able to use the dual optical ports to transmit 2x video signals in which on...

Page 43: ...nfigurations you set before 4 After the system restart you can see the configured single ports with single mode in the Input Ports and Output Ports list Factory config You can reset the factory settin...

Page 44: ...Software 41 License For renew your license please contact your sales or contact our team sales digibirdtech com...

Page 45: ...ransmission of audio and video data It is differentiated between the DisplayPort standards 1 1 and 1 2 The signals have LVDS level DVI Digital video standard introduced by the Digital Display Working...

Page 46: ...DigiBird Technology Co Ltd Web www digibirdtech com Email sales digibirdtech com...

Reviews: