AT commands
Coordinator/End Device configuration commands
Digi XBee® 3 802.15.4 RF Module User Guide
134
Note
If
CE
=
1
and
SP
is not
0
, then all messages are sent indirectly. See
for more information.
A1 (End Device Association)
Sets or displays the End Device association options.
Parameter range
0 - 0x0F (bit field)
Bit field:
Bit Meaning
Setting Description
0
Allow PanId
reassignment
0
Only associates with Coordinator operating on PAN ID that
matches device ID.
1
May associate with Coordinator operating on any PAN ID.
1
Allow Channel
reassignment
0
Only associates with Coordinator operating on matching
CH
channel setting.
1
May associate with Coordinator operating on any channel.
2
Auto Associate
0
Device will not attempt association.
1
Device attempts association until success.
3
Poll coordinator on pin
wake
0
Pin Wake does not poll the Coordinator for indirect (pending)
data.
1
Pin Wake sends Poll Request to Coordinator to extract any
pending data.
4 -
7
Reserved
Default
0
A2 (Coordinator Association)
Sets or displays the Coordinator association options. These options are only applicable when
configured as a coordinator by setting
to
1
.
Parameter range
0 - 7 (bit field)
Bit field: