I N S T R U C T I O N M A N U A L
HOSE END
WATERING
TIMER
CO72A
TAblE Of CONTENTS
INTRODuCTION
Introduction........................................1
Glossary..............................................2
Battery.installation.............................3
Timer.installation................................4
Technical.data.....................................5
Programming
Set.automatic.watering......................6
Changing.start.time............................7
Manual.start........................................8
Stop.or.NO.watering...........................9
Red.LED.-.operating.states..............10
Extra.watering.cycles.......................11
Troubleshooting................................12
Warranty...........................................14.
Notes.................................................13
CO72A.-.Hose.End.Watering.Timer
Thank you for purchasing this timer, please read
the operating instructions carefully to familarize
yourself with the features and modes of operation
before using the Hose End Watering Timer.
1
2
3
GlOSSARy
1. Inlet: 3/4 in. female hose
end connection
2. Union nut
3. Control dials
4. Battery compartment
5. Clear screw-on cover
6. Outlet: 3/4 in. male
hose end
1
2
3
4
5
6
bATTERy INSTAllATION
TIMER INSTAllATION
TECHNICAl DATA
SET AuTOMATIC WATERING
4
5
6
Make sure the filter is in place and screw the
timer to the outdoor faucet by attaching the side
with the female hose thread connection to the
faucet or hose end, then turn it clockwise (A) -
hand tighten only. Loosen the union nut to allow
the hose end connection to swivel (B). Be sure
to re-tighten the union nut after the hose end
connection is tightened. Connect the timer male
hose thread side to your system or garden hose.
DIG.-.2.Dial.Hose.End.Watering.Timer
Model.Number:.
CO72A
Operating.Pressure:.
10-90 PSI
Battery:.
Use a standard 9 Volt
ALKALINE
battery.
Fluid:.
Only use cold water with NO
added chemicals.
Frequency.Options:
Every 6 hrs, 12 hrs, 24 hrs, 48 hrs, Every 3rd Day,
Every 4th Day, Every 5th Day, Every 7th Day.
Run.Time.Options:
2, 5, 10, 15, 30, 60, 120 or 240 Minutes.
SET.RUN.TIME.&.WATERING.INTERVAL
1..
Turn
“LEFT”
dial to select RUN TIME.
2..
Turn
“RIGHT”
dial to select INTERVAL.
3..
Push
“ENTER”
- The Red LED will appear solid
for
10.seconds
to confirm your selections, and
then it will initially water for the duration of the
selected RUN TIME.
In.24.hrs.the.timer.will.begin.operating.at.the..
selected.INTERVAL.
CHANGING START TIME
MANuAl START
STOp OR NO WATERING
RED lED – OpERATING STATES
7
8
9
10
TO.CHANGE.THE.START.TIME..
(Minimum.6.Hours)
1..
While the Red LED is solid ON (see pg 6, step 3),
turn the
“RIGHT”
dial to select the DELAY time
& press
“ENTER”
again. This moves the START
time forward by the hours selected.
RUN.TIME.will.begin.at.that.time.&.thereafter.at.
the.selected.INTERVAL.
HOW.TO.STOP.THE.TIMER.WATERING
1..
Turn
.“LEFT”.
dial to the OFF position.
While.the.RUN.TIME.(left).dial.is.in.the.“OFF”.
position.NO.watering.will.happen.
Note:.
To re-commence automatic operation,
move the
“RUN.TIME”
dial to any other position.
SETTING.THE.TIMER.TO.START.MANUALLY
1..
Turn
“LEFT”
dial to select RUN TIME.
2.
Turn
“RIGHT”
dial to MAN and press
“ENTER”
.
Note:.
Running a manual run time will not change
any program previously entered.
Watering.will.begin.and.end.at.selected..
RUN.TIME.
Red.LED.-.OPERATING.STATES
as.follows:..
1..SOLID:
Confirms program & allows
“START.TIME”
change
2..FLASHING
-.30.Seconds:.
“ALL.IS.RUNNING.CORRECTLY”
3..FLASHING
-.1.Second
:
“BATTERIES.NEED.CHANGING”
11
14
12
13
ExTRA WATERING CyClES
TROublESHOOTING
WARRANTy
WARRANTy
The manual operation mentioned previously
(pg. 8), can be used for running an extra cycle
while the timer is programmed.
The
“MANUAL”
cycle will run immediately after
the enter button is pressed.
The timer will resume the automatic program
once the manual time has elapsed.
1..
Ensure your faucet is turned on.
2. Ensure your battery is in good condition.
USE.ONLY.ALKALINE.BATTERIES.
Note:
When the timer is not using an automatic
program, it must be in the
“OFF”
position.
Turn the faucet
“OFF”
when the timer is not in use.
MAINTENANCE
Turn the faucet off when the timer is not in use.
Check and clean screen washer periodically
as needed.
Remove the battery if the timer will not be used for
a prolonged time.
Shut off faucet and bring timer indoors when
temperatures drop below freezing.
DIG CORPORATION warrants these products to be free
from defects in material and workmanship for a period
of one (1) year from date of purchase. DIG will repair or
replace, at its option, free of charge, this product if it has
proven to be defective within the one year period when
said product is returned at customer expense to DIG
within the warranty period. THIS WARRANTY DOES NOT
COVER ANY EXPENSES INCURRED IN THE REMOVAL AND
REINSTALLATION OF THIS PRODUCT. This warranty does
not cover damage resulting from accident, misuse, abuse,
neglect, modification or improper installation, use for other
than its intended purpose or use with water with subjection
to line pressure in excess of 80 lbs. per square inch. This
warranty shall extend only to the original purchaser of the
product for use by the purchaser. This warranty shall not
cover batteries or any malfunction of the product due to
battery failure. The obligation of DIG CORPORATION under
this warranty is limited to repairing or replacing at its
factory this product which shall be returned to the factory
within one year after the original purchase and which on
examination is found to contain defects in material and
workmanship. DIG CORPORATION SHALL IN NO EVENT
BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY KIND; THE SOLE OBLIGATION OF
DIG BEING LIMITED TO REPAIR OR REPLACEMENT OF
DEFECTIVE PRODUCTS. SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION
OR EXCLUSION MAY NOT APPLY TO YOU. Unattended use
for prolonged periods without inspection to verify proper
operation is beyond the intended use of this product,
and any damage resulting from such use shall not be
the responsibility of DIG CORPORATION. There are no
warranties which extend beyond the description on the face
hereof. In the case of purchase of the product for use other
than for irrigation purposes, DIG CORPORATION hereby
disclaims any implied warranties including any warranties of
merchantability and fitness for a particular purpose.
WARRANTy
TECHNICAl ASSISTANCE
NOTES
1210 Activity Drive
Vista, CA 92081-8510, USA
www.digcorp.com
e-mail: [email protected]
Should you encounter any problem(s) with this
product or if you do not understand its many
features, please refer to this instruction first.
If further assistance is required, DIG offers the
following customer support:
Technical Service USA
DIG’s Technical Service Team is available to
answer questions in English and Spanish from
8:00 AM to 5:00 PM (PST) Monday-Friday (except
holidays) at 800-344-2281. Questions
.
in
.
English
and Spanish can be e-mailed to questions@
digcorp.com or faxed to 760-727-0282.
In the case of the purchase of the product for personal,
family or household purposes, DIG CORPORATION disclaims
any such warranties to the extent permitted by law. In order
to obtain performance under this warranty, the unit must
be returned to the factory, along with proof of purchase
indicating original date of purchase, shipping prepaid,
addressed as follows:
DIG CORPORATION, 1210 Activity Drive, Vista,
CA 92081-8510. Repaired or replaced units will be shipped
prepaid to the name and address supplied with the unit
returned under warranty.
Allow four weeks for repairs and shipping time. Repair
of damaged units not otherwise within warranty may be
refused or done at a reasonable cost or charge at the option
of DIG CORPORATION. This warranty gives you specific legal
rights, and you may also have other rights, which vary from
state to state.
15
16
17
26-231 REVA
A
B
• Unscrew and remove clear cover.
• Hold the timer with the battery
compartment facing you.
• Remove the battery
compartment cover
towards you
• Connect a
9V battery to the
battery connector.
• Insert the connected
battery and press on the
battery cover.
NOTE:
When battery is first fitted, it takes up to
1 minute for the battery indicator to assess the
battery strength.
NOTE:
When changing the battery, make sure
the battery compartment stays dry.
USE.ONLY.ALKALINE.BATTERIES.