OPERATION
4.1 GENERAL NOTES ON OPERATION
IMPORTANT NOTE
Before connecting the “SUZO” Table to a power source, ensure that all columns
are connected to the control unit
Once the assembly is complete, connect the power cable to the table and the former to a power
source.
At first use, press the DOWN ▼ button (button 2, Fig. 4.1) and hold it for 5 seconds to synchro-
nize columns and beam.
The table is synchronized and ready for use by means of the two buttons shown in Fig. 4.1.
If during operation (ascent or descent) the tabletop runs into obstacles, the ISP security mecha-
nism stops the table and moves it about 25 mm away from the obstacles.
Overheating
A heat control switch turns off the control unit in case of overheating.
ATTENTION
The control unit is equipped with a heat control device (circuit break
-
er), which is activated when the unit overheats as a result of con
-
tinuous use. The heat control device (circuit breaker) suspends the
supply of electricity to the control unit. When overheating occurs, let
the product rest for 20-30 minutes before resuming operations. If the
control unit does not respond, contact our Customer Assistance.
4.2 CONTROL KEYPAD
Connect the plug to a power source to begin operations.
IMPORTANT NOTE
After connecting the unit to a power source, wait at least seven seconds before
starting to begin using the “SUZO” Table, since the supply voltage will become
available with a slight delay.