background image

English

7. FIXING

The electronic unit and the locking cover can be inserted 
with the supply voltage connected. Ensure that the 
upper holders are engaged correctly so that the housing 
can be mounted twist free. 

The SIM card (optional) can only be used in the printed 
and potential free version.

The LAN-cable will be plugged in the RJ45 socket. Please 
use the pull relief to protect the connection.

After the mounting 

the cover plate will 
be screwed and 
the screws can be 
sealed.

Summary of Contents for IZAR RDC STANDARD

Page 1: ...Installationsanleitung Deutsch IZAR RDC STANDARD ...

Page 2: ...Deutsch 1 VERPACKUNGSINHALT Bitte kontrollieren Sie vor der Installation bzw Inbetriebnahme den Verpackungsinhalt 1 x Gehäusehauptteil 1 x Montageplatte 1 x Anschlussdeckel 2 x Schrauben und Dübel ...

Page 3: ... zu einem zukunftsfähi gen Kernprodukt für flächendeckende Smart Metering Roll Outs mit Multi Utility Ansatz IZAR RDC STAN DARD ist konzipiert um ein Funk Fixed Network unter wirtschaftlichen und technischen Aspekten bestmöglich umzusetzen 3 TECHNISCHE DATEN Kommunikation LAN Ethernet 10 100 Base T LAN Interface IEEE 802 3 GSM GPRS 1 externer Antennenanschluss mit SMA Stecker optional ISM wM Bus 2...

Page 4: ...mA bei 100V 4 HINWEISE Der IZAR RDC STANDARD darf nur von quali fizierten Fachkräften montiert und in Betrieb genommen werden Das Gleiche gilt für Ser vicearbeiten während des Betriebes Bei Nichtbeachten besteht die Gefahr schwerer gesundheitlicher Schäden oder Lebensgefahr durch elektrische Stromschläge Bei Gerätefehlern verwenden Sie dieses Gerät nicht mehr und kontaktieren Sie sofort den zustän...

Page 5: ...arf nicht geöffnet werden Der elektrische Anschluss die Verbindung mit dem Ethernet LAN Anschluss und das Einstecken der SIM Karte dür fen nur im stromlosen Zustand erfolgen 5 MONTAGE Der IZAR RDC STANDARD ist für die Montage an einer ebenen Wand vorgesehen Dazu ist die Montageplatte mit den 2 Schrauben zu benutzen Es ist bei der Montage auf verwindungsfreien Zustand der Montageplatte und die Schu...

Page 6: ...ssleitung achten Bitte immer Abdeckklappe des Kabelanschlusses verschrauben Es dürfen nur starre Elektrokabel benutzt werden die zur Festinstallation geeignet sind Zur Kabeldurchführung können auch die vorderen Elemente entfernt werden Außerhalb der Einrichtung ist eine Trennstelle vorzusehen ...

Page 7: ...eingeführt sind damit das Gehäuse verwind ungsfrei montiert werden kann Die SIM Karte optional darf nur in der aufgedruckten Art und spannungsfreiem Zustand erfolgen Das LAN Kabel wird in die RJ45 Buchse gesteckt Bitte benutzen Sie die Zugentlastung um die Verbindung zu schützen Nach der Montage und Befestigung wird die Abdeck platte verschraubt und kann an den Schrauben ver plombt werden ...

Page 8: ...ur im Innenbereich installiert werden Die maximal erlaubte Kabellänge der externen GSM GPRS Antenne beträgt 1m Bei Schäden durch den Einfluss von extern angeschlossenen Antennen sind von der Haftung ausgeschlossen z B Blitzschlag Kondensation Verwenden Sie nur Antennen welche von DIEHL Meter ing spezifiziert sind 9 ANZEIGEELEMENTE Zur Identifikation des Betriebszustandes dienen 2 inte grierte LEDs...

Page 9: ...Deutsch R TTE 11 ZULASSUNG UND KONFORMITÄT Mat Nr 3019832 Version 01 2012 ...

Page 10: ...Deutsch Support HYDROMETER GmbH Industriestraße 13 91522 Ansbach support hydrometer de 49 981 1806 0 www hydrometer de ...

Page 11: ...Installation guide English IZAR RDC STANDARD ...

Page 12: ...lish 1 CONTENT OF PACKAGE Please check the content of the package before com mencing installation and taking into operation 1 x main housing 1 x mounting plate 1 x terminal cover 2 x screws and wall plugs ...

Page 13: ...h a multi utility approach The IZAR RDC STANDARD is designed for implementing a radio fixed network with excellent cost effectiveness and technical specification 3 TECHNICAL DATA Communication LAN Ethernet 10 100 Base T LAN interface IEEE 802 3 GSM GPRS 1 external antenna plug with SMA plug optional ISM wM Bus 2 external antenna plugs with SMA plug optional Ambient conditions Protection type IP 40...

Page 14: ... remove it from use and contact the responsible customer support team immediately Examples of equipment faults are a damaged housing or cable or liquid in the housing The relevant electrostatic discharge regulations ESD must be observed The housing must not be opened The equipment must be discon nected from the mains supply before connecting the electrical supply and Ethernet LAN cables and insert...

Page 15: ... STANDARD is intended for installation on a flat wall using the mounting plate and the 2 screws Ensure that the mounting plate is installed free of twisting and that the ambient conditions meet the requirements for protection class IP40 ...

Page 16: ...quipment Always fix the terminal cover of the cable connection with the screws This also provides the strain relief Only stiff electronic cables can be used which are applicable at fixed installations For the cable penetration the front elements can be removed A disconnection point must be provided outside the equipment ...

Page 17: ...ders are engaged correctly so that the housing can be mounted twist free The SIM card optional can only be used in the printed and potential free version The LAN cable will be plugged in the RJ45 socket Please use the pull relief to protect the connection After the mounting the cover plate will be screwed and the screws can be sealed ...

Page 18: ...onnections The external antennas are only for use indoors The maximum permissible length of cable for the external GSM GPRS antenna is 1 m No liability is accepted for damage due to external antennas e g lightning strike condensation Use only antennas specified by DIEHL Metering 9 DISPLAY ELEMENTS The operating status is indicated by 2 integrated LEDs on the front 10 PROGRAMMING Programming is per...

Page 19: ...English 11 APPROVAL AND CONFORMITY Mat Nr 3019832 Version 01 2012 R TTE ...

Page 20: ...English Support HYDROMETER GmbH Industriestraße 13 91522 Ansbach support hydrometer de 49 981 1806 0 www hydrometer de ...

Page 21: ...Instructions d installation IZAR RDC STANDARD Français ...

Page 22: ...ais 1 CONTENU DE L EMBALLAGE Avant l installation et la mise en service veuillez vérifier le contenu de l emballage 1x boîtier principal 1 x plaque de montage 1 x couvercle de protection 2 x vis et chevilles ...

Page 23: ...proche multi énergie IZAR RDC STANDARD est conçu pour le déploiement de réseau radio fixe IZAR avec un renvoi des informations par GPRS ou LAN 3 CARACTÉRISTIQUES TECHNIQUES Communication LAN Ethernet 10 100 Base T LAN Interface IEEE 802 3 GSM GPRS 1 Connecteur d antenne externe SMA en option ISM wM Bus 2 Connecteurs d antenne exter ne SMA en option Environnement Indice de protection IP 40 Classe d...

Page 24: ...areil et contactez le service après vente Sont considérés comme défauts les dommages sur le boîtier ou le câble d alimentation la présence d humidité importante dans le boitier Les précautions contre les décharges électrosta tiques ESD doivent être observées Le boîtier principal ne doit pas être ouvert Le raccorde ment de l alimentation électrique le branchement à Ethernet LAN et la mise en place ...

Page 25: ...çu pour un montage mural Pour cela utiliser la plaque de montage et les 2 vis livrées avec le produit Lors de l installation veiller à ce que la plaque de monta ge soit installée de façon plane sans torsion et respecter les exigences de la classe de protection IP40 ...

Page 26: ...le raccorder le connecteur inférieur Fermer le capot de protection noir par l intermédiaire des vis Seuls les câbles électriques rigides peuvent être utilisés pour une installation définitive Les éléments inférieurs avant de la partie basse peuvent être retirés permettant le passage des câbles ...

Page 27: ...orrectement insérés pour un parfait maintien du boîtier La carte SIM pour la version GPRS en option peut être installée facilement dans la partie basse du boîtier Le câble réseau LAN doit être branché dans la prise RJ45 Veuillez utiliser un réducteur de tension pour protéger la connexion Le couvercle de pro tection doit être vissé et peut être plombé au niveau des vis ...

Page 28: ...s utilisés doivent obligatoirement être ceux fournis par DIEHL Metering Nous déclinons toute responsabilité pour les dommages causés par l utilisation d antennes ou câbles non validés par DIEHL METERING par ex foudre condensation 9 INDICATEURS L état de fonctionnement est indiqué par deux LED intégrées sur la face avant du boîtier principal 10 PROGRAMMATION La programmation s effectue exclusivemen...

Page 29: ...Français 11 HOMOLOGATION ET CONFORMITE Mat Nr 3019832 Version 01 2012 R TTE ...

Page 30: ...Français Assistance HYDROMETER GmbH Industriestraße 13 91522 Ansbach support hydrometer de 49 981 1806 0 www hydrometer de ...

Page 31: ...Guía de instalación IZAR RDC STANDARD Español ...

Page 32: ...añol 1 CONTENIDO DEL EMBALAJE Antes de la instalación o puesta en servicio compruebe el contenido del embalaje 1 x Pieza principal carcasa 1 x Placa de montaje 1 x Tapa de la conexión 2 x Tornillos y tacos ...

Page 33: ...ligente de amplia extensión y la fórmula de proveer electricidad agua gas y teléfono IZAR RDC STANDARD ha sido concebido para aplicar de la mejor forma posible una red fija por radio desde el punto de vista económico y técnico 3 DATOS TÉCNICOS Comunicación LAN Ethernet Interfaz de red 10 100 Base T IEEE 802 3 GSM GPRS 1 toma de antena externa con enchufe SMA opcional ISM wM Bus 2 tomas de antena e...

Page 34: ...e de usarlo y póngase en contacto de inmediato con la asi stencia técnica al cliente respectiva El aparato es defectuoso por ejemplo si hay daños en la carcasa o en el cable de alimentación o hay líquido en la carcasa Deben tenerse en cuenta las normas vigentes contra descarga electroestática ESD No debe abrirse la carcasa La conexión eléctrica la cone xión con el Ethernet LAN y la introducción de...

Page 35: ...ha sido concebido para mon tarse en una pared lisa Para ello debe usarse la placa de montaje con 2 tornillos Debe prestarse atención a eléctrica sin torsión durante el montaje de la placa de montaje ni el entorno de clase de protección IP40 ...

Page 36: ... de realizar la conexión eléctrica Atornille siempre la cubierta de la conexión de cables Pueden usarse solo cables eléctricos rígidos adecuados para la instalación fija Para pasar el cable pueden quitarse también los elemen tos delanteros Debe preverse un punto de disyun ción fuera del dispositivo ...

Page 37: ...amente de lo contrario podrían producirse tensiones en la carcasa para que la carcasa pueda montarse sin torsión La tarjeta SIM opcional puede usarse solo en el modo impreso y en un estado sin tensión El cable LAN se introduce en el casquillo RJ45 Rogamos use el descargador de cable para proteger la unión Tras el montaje y la sujeción se atornilla la tapa y puede precin tarse en los tornillos ...

Page 38: ... conexiones La antenas externas solamente se pueden instalar en interiores La longitud del cable máxima permitida de la antena externa GSM GPRS es 1m Los daños por antenas externas están excluidos de la responsabilidad p ej rayo condensación Emplee solo las antenas especificadas por DIEHL Mete ring 9 ELEMENTOS INDICADORES Para identificar el estado de funcionamiento hay 2 leds integrados en la par...

Page 39: ...Español 11 HOMOLOGACIÓN Y CONFORMIDAD Mat Nr 3019832 Version 01 2012 R TTE ...

Page 40: ...Español Asistencia técnica HYDROMETER GmbH Industriestraße 13 91522 Ansbach support hydrometer de 49 981 1806 0 www hydrometer de ...