DieHard 28.71520 Operator'S Manual Download Page 5

• 2 •

IMPORTANT SAfETY INSTRUcTIONS

1. 

SAvE ThESE INSTRUcTIONS

Risk of electric shock or fire.

Keep out of reach of children.

1.1 

Keep the inverter well ventilated in order to properly disperse heat generated 

1.2 

while it is in use. Make sure there are several inches of clearance around the 

top and sides and do not block the slots of the inverter.

Make sure the inverter is not close to any potential source of flammable 

1.3 

fumes, gases or clothing.
do not place the inverter in areas such as battery compartments or engine 

1.4 

compartments where fumes or gases may accumulate.
Keep the inverter dry.

1.5 

dO NOT allow the inverter to come into contact with rain or moisture.

1.6 

dO NOT operate the inverter if you, the inverter, the device being operated 

1.7 

or any other surfaces that may come into contact with any power source are 

wet. Water and many other liquids can conduct electricity, which may lead to 

serious injury or death.
do not place the inverter on or near heating vents, radiators or other sources 

1.8 

of heat or flammable materials.

do not place the inverter in direct sunlight. The ideal air temperature for 

1.9 

operation is between 50° and 80°F.
Only connect the power inverter to a 12-volt accessory outlet. do not attempt 

1.10 

to connect the inverter to any other power source, including an AC power 

source. Connecting to a 6-volt or 16-volt battery will cause damage to  

the inverter.
Make sure the AC plug connection is tight.

1.11 

do not modify the inverter in any way including cables, plugs or switches as it 

1.12 

may result in property damage or personal injury.
Incorrect operation of your inverter may result in damage and personal injury. 

1.13 

 

The inverter output is 110V AC and can shock or electrocute 

the same as any ordinary household AC wall outlet.
do not open – No user serviceable parts inside.

1.14 

This device does not include an internal Ground Fault Circuit  

1.15 

Interrupter (GFCI). 
Use only 15-amp fuses.

1.16 

Summary of Contents for 28.71520

Page 1: ...NUAL 120 Watt Power Inverter Model No 28 71520 Read and follow all Safety Rules and Operating Instructions before Every Use of this Product Save these instructions Sears Brands Management Corporation Hoffman Estates IL 60179 U S A ...

Page 2: ......

Page 3: ...and maintained according to all supplied instructions if this DieHard product fails due to a defect in material or workmanship within 1 year from the date of purchase return it to any DieHard outlet in the United States for free replacement This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Brands Management Corporation Hoffman Est...

Page 4: ... serious injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in death or serious injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in moderate or minor injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in da...

Page 5: ...n conduct electricity which may lead to serious injury or death Do not place the inverter on or near heating vents radiators or other sources 1 8 of heat or flammable materials Do not place the inverter in direct sunlight The ideal air temperature for 1 9 operation is between 50 and 80 F Only connect the power inverter to a 12 volt accessory outlet Do not attempt 1 10 to connect the inverter to an...

Page 6: ...provide as this may cause damage to the inverter and product When you turn on a device or a tool that runs on a motor the device basically goes through two stages Start Up Requiring an initial surge of power commonly known as the 1 starting or peak load Continuous Operation Power consumption drops commonly known as 2 the continuous load The wattage WATTS or amperes AMPS can normally be found stamp...

Page 7: ...put you must purchase a 12 volt accessory outlet to battery clips adapter and connect the inverter directly to the battery NOTE The 100 watt limit is to accommodate the fuse ratings for all vehicles Some vehicles may allow the full output If the vehicle s fuse blows when you switch on the device you are trying to use you have to either use a smaller device or you must purchase the 12 volt accessor...

Page 8: ...ed is turned OFF Plug the device into the Travel Inverter AC outlet or USB port Turn the device on If the device doesn t work and the LED blinks refer to section 4 To disconnect reverse the above procedure NOTE You may hear a buzzing sound being emitted from inexpensive sound systems when operated with the inverter This is due to ineffective filters in the sound system s power supply Unfortunately...

Page 9: ...the continuous rated output RESET To reset after shutdown occurs remove the 12 volt plug from the accessory outlet Check the source of the problem and correct Reinsert the 12 volt plug into the accessory outlet POWER SOURCE 6 Your average automobile or marine battery at full charge will provide an ample power supply to the inverter for approximately 3 hours when the engine is off The actual length...

Page 10: ...of the plug on 3 the inverter Do not tighten the fuse cap too tight finger tight is sufficient 4 Do not install a fuse higher than 15 amp as this may damage the inverter Make sure to correct the cause of the blown fuse before using the inverter again Troubleshooting 8 PROBLEM REASON SOLUTION LED does not light or inverter does not function Poor contact at terminals Fuse Blown Inverter shutdown Inv...

Page 11: ...5 USA 110V AC 3 Prong USB Port One 5V 0 5A Dimensions 3 75 H x 2 75 W x 875 D Product Weight Approximately 4 lbs Fuse 15 Amp 250V BEFORE RETURNING FOR REPAIRS 10 When an UNKNOWN OPERATING PROBLEM arises please read the complete manual and call the customer service number for information that will usually eliminate the need for return If the above solutions do not eliminate the problem or for infor...