background image

 6 

Battery type Button 

Use this button to set the type of battery to be charged.

Standard

• 

 

 Set the button to 12V STANDARD or 6V STANDARD. 

deep-Cycle

• 

 

 Set the button to 12V DEEP CYCLE. 

AGM –

• 

 Set the button to 12V AGM/GEL. 

GEl –

• 

 Set the button to 12V AGM/GEL. 

Charge rate Button

 

Use this button to set the maximum charge rate.

2A Slow Charge rate

• 

 

 Intended for charging small batteries such as those 

commonly used in garden tractors, snowmobiles and motorcycles. 

12A Fast and 30A rapid Charge rate

• 

 

 Use for charging automotive, marine and 

deep-cycle batteries. Not intended for industrial applications.

80A Engine Start

• 

 

 Provides 80 amps for cranking an engine with a weak or run 

down battery. Always use in combination with a battery.

opErAtinG inStruCtionS

11. 

 This battery charger must be properly assembled in accordance with 

the assembly instructions before it is used.
The charger does not have an On/Off switch. The On and Off commands are controlled 

by plugging the 71225 into a 120V AC electrical wall outlet only after the battery 

connections have been made.

Charging

Ensure that all of the charger components are in place and in good working 

1. 

condition, for example, the plastic boots on the battery clips.
Connect the battery following the precautions listed in sections 6 and 7.

2. 

Connect the AC power, following the precautions listed in section 8.

3. 

Select the appropriate settings for your battery.

4. 

notE: 

This charger is equipped with an auto-start feature. It will not supply current to 

the battery clips until a battery is properly connected. Meaning, the clips will not spark if 

touched together. 

Battery Connection indicator 

If the charger does not detect a properly connected battery, the CHECK (red) LED will 

light. Charging will not begin if the CHECK (red) LED is on. 

Automatic Charging Mode

 

When an Automatic Charge is performed, the charger switches to the Maintain Mode 

(see below) automatically after the battery is charged. For a battery with a starting 

voltage under 0.1 volt, the charger will not recognize that the battery is connected and 

the CHECK (red) LED will stay lit. In order to charge the battery, use a manual charger 

to pre-charge the battery for five minutes to get additional voltage into the battery.

Aborted Charge 

If charging cannot be completed normally, charging will abort. When charging aborts, 

the charger’s output is shut off, the CHECK (red) LED will blink and the digital display 

will show a failure code (see the TROUBLESHOOTING section for a description of the 

failure codes). In that state, the charger ignores all buttons. To reset after an aborted 

charge, unplug the charger, wait a few moments, then plug it back in.

desulfation Mode

 

If the battery is left discharged for an extended period of time, it could become sulfated 

and not accept a normal charge. If the charger detects a sulfated battery, the charger 

will switch to a special mode of operation designed for such batteries. If successful, 

normal charging will resume after the battery is desulfated. Desulfation could take 8 to 

10 hours. If desulfation fails, charging will abort, the CHECK (red) LED will blink and the 

digital display will show a failure code of F02 (bad battery).

Summary of Contents for 28.71225

Page 1: ...Manual del usuario Read and follow all safety rules and operating instructions before every use of this product Save these instructions Lea todas las instrucciones de operaci n y reglas de seguridad...

Page 2: ...ts call toll free from 7 am to 5 pm CT Monday through Friday 1 800 732 7764 TRES A OS DE GARANT A TOTAL EN DIEHARD Cuando se opere o maneje con las debidas precauciones de acuerdo a las instrucciones...

Page 3: ...snow 1 2 Use only recommended attachments Use of an 1 3 attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to persons or damag...

Page 4: ...rst and cause injury to persons and damage to property NEVER charge a frozen battery 2 5 NEVER overcharge a battery 2 6 Consider having someone nearby to come to your aid when you work near a 2 7 lead...

Page 5: ...ug from the electrical outlet Never allow the clips to touch each other Attach the clips to the battery and chassis as indicated in sections 6 and 7 5 2 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN...

Page 6: ...pply cord to electrical outlet 7 6 When disconnecting the charger always do so in the reverse order of the connecting 7 7 procedure and break the first connection while as far away from the battery as...

Page 7: ...cause the charger to recalculate the percentage and may display a different percentage than was previously indicated Voltage The digital display shows the voltage at the charger battery clips in DC vo...

Page 8: ...rrent to the battery clips until a battery is properly connected Meaning the clips will not spark if touched together Battery Connection Indicator If the charger does not detect a properly connected b...

Page 9: ...e charger to the battery 1 following the instructions given in section 6 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE Plug the charger AC power cord into the AC outlet 2 With the charger pl...

Page 10: ...rates only as a tester not as a charger To continue to use it only as a tester avoid pressing the CHARGE RATE button Selecting a charge rate activates the battery charger and deactivates the tester Pr...

Page 11: ...s 2 2 hrs 45 min 1 hr 315 550 CCA 60 85 RC 14 18 hrs 2 3 hrs 1 1 hrs 550 1000 CCA 80 190 RC 18 34 hrs 3 5 hrs 1 2 hrs MARINE DEEP CYCLE 80 RC NR 3 hrs NR 140 RC NR 4 hrs NR 160 RC NR 5 hrs NR 180 RC N...

Page 12: ...in No power at the receptacle Plug the charger into an AC outlet Check for open fuse or circuit breaker supplying AC outlet Digital Display reads LO when testing the alternator The alternator output...

Page 13: ...an the engine start rate crank time may be less than 5 seconds Wait 3 minutes of rest time before the next crank Check for poor connection at battery and frame Check power cord and extension cord for...

Page 14: ...charged or sulfated it will not draw the full rated 16 2 amperes from the charger It is both dangerous and damaging to a battery to force higher amperage into it than it can effectively use in rechar...

Page 15: ...el fabricante del cargador de bater as puede provocar riesgo de incendio descarga el ctrica o lesiones a personas o da o a la propiedad Para reducir el riesgo de da os al enchufe o cable el ctrico jal...

Page 16: ...tinado a suministrar energ a a sistemas el ctricos de baja tensi n m s que en una aplicaci n de un motor de arranque No utilice este cargador de bater a para cargar bater as de pila seca que por lo ge...

Page 17: ...O DE LA BATER A Ubique el cargador a la mayor distancia 4 1 posible de la bater a como lo permitan los cables de CC Nunca ubique el cargador directamente 4 2 por encima de la bater a que se carga los...

Page 18: ...el gancho del terminal perteneciente a la bater a Ver la secci n C LCULO DEL TIEMPO DE CARGA por la informaci n sobre la duraci n 6 9 de carga SIGA ESTOS PASOS CUANDO LA BATER A SE ENCUENTRE FUERA 7...

Page 19: ...iesgo de descarga el ctrica o electrocuci n NOTA De acuerdo a las Leyes Canadienses el uso de un enchufe adaptador no es permitido en el Canada El uso de un enchufe como adaptador no se recomienda y n...

Page 20: ...or Obs rvelo por un par de minutos despu s de usted haya apagado los faros Si indica menos de 10 5 voltios la bater a puede estar defectuosa o la conexi n en el cargador puede que no est hacienda buen...

Page 21: ...cargador manual para pre cargar la bater as por espacio de cinco minutos para incorporar voltaje adicional a la bater a Carga anulada Si la carga no puede completarse normalmente la carga ser rechaza...

Page 22: ...y la bater a que se enfr en NOTA Bajo clima fr o extremo o si la bater a es inferior a 2 volts cargue la bater a por 5 minutos antes de poner en marcha el motor Si el motor no arranca cargue la bater...

Page 23: ...durante los 180 segundos de enfriamiento cerrar el cargador y activar el probador Encender el l mite de tiempo de inactividad Si no se presiona un bot n dentro de los 10 minutos despu s de que el car...

Page 24: ...CAMIONES 200 315 CCA 40 60 RC 11 14 hrs 2 2 hrs 45 min 1 hr 315 550 CCA 60 85 RC 14 18 hrs 2 3 hrs 1 1 hrs 550 1000 CCA 80 190 RC 18 34 hrs 3 5 hrs 1 2 hrs MARINA CICLO PROFUNDO 80 RC NR 3 hrs NR 140...

Page 25: ...a pantalla digital Cargador desenchufado No hay electricidad en el tomacorriente Enchufe el cargador a un tomacorriente de CA Verifique la posible presencia de fusibles abiertos o disyuntores que sumi...

Page 26: ...amperes 12V No espera 3 minutos 180 segundos entre los arranques Los ganchos no se encuentran bien conectados Cable de C A o alargador suelto No hay electricidad en el tomacorriente El cargador podr...

Page 27: ...DEVOLVER A REPARACIONES 16 Cuando surja un problema de carga aseg rese de que la bater a puede recibir una 16 1 carga normal Verifica dos veces todas las conexiones el toma de C A para obtener 120 vo...

Reviews: