DieHard 28.71221 Operator'S Manual Download Page 8

 6 

Recommended minimum AWG size for extension cord:

8.3 

100 feet long or less - use a 16 gauge extension cord.

• 

Over 100 feet long - use a 14 gauge extension cord.

• 

ASSEMBLY INSTRUCTIONS

9. 

Remove all cord wraps and uncoil the cables prior to using the battery charger. 

FEATURES/CONTROL PANEL

10. 

Ammeter

1. 

Charge Rate Selector Switch

2. 

Battery Clips

3. 

1

2

3

Setting the controls  

All of the controls for your charger are located on the front of the charger. Read these 

instructions to properly set the charger controls.

Ammeter

 

The Ammeter indicates the amount of current, measured in amps, that is being drawn 

by the battery. As a battery takes on a charge, it draws less current from the charger. 

Correspondingly, the meter will show less current being drawn by the battery. When the 

current stops decreasing, the battery is charged. 
The 2 amp charge rate may indicate some activity on the meter, although the meter 

does not have the resolution to display this low rate. For the 2 amp charge rate, a 

triangle has been provided. Its accuracy has been calibrated for use with small batteries. 

Percent of Charge

• 

 

The percent of charge is based on the current drawn by the battery. For this reason, 

accuracy will vary with the size and battery type. 

Charge Rate Selector Switch: 

Use the Charge Rate Selector switch to select the charge rate setting you require.

OPERATINg INSTRUCTIONS

11. 

 This battery charger must be properly assembled in accordance with 

the assembly instructions before it is used.
The charger does not have an On/Off switch. The On and Off commands are controlled 

by plugging the 71221 into a 120V AC electrical wall outlet only after the battery 

connections have been made.

NOTE: 

Once the charger is plugged in, the battery clips are live. Make sure they are 

properly connected to the battery before plugging the charger into an AC outlet or it 

could cause a short circuit that may cause personal injury and/or property damage. 

Summary of Contents for 28.71221

Page 1: ...1221 00 99 001008 01 12V Manual Battery Charger Read and follow all Safety Rules and Operating Instructions before Every Use of this Product Save these instructions Sears Brands Management Corporation...

Page 2: ...tes IL 60179 For customer assistance or replacement parts call toll free from 7 am to 5 pm CT Monday through Friday 1 800 732 7764 Table of Contents Section Page IMPORTANT SAFETY INSTRUCTIONS 1 PERSON...

Page 3: ...ces state the hazard Numbered sentences state how to avoid the hazard The icon gives a graphical description of the potential hazard Pursuant to California Proposition 65 this product contains chemica...

Page 4: ...f the battery Review the cautionary markings on these products and on the engine This charger employs parts such as switches and circuit breakers that tend to produce 1 12 arcs and sparks If used in a...

Page 5: ...ose or mouth Add distilled water to each cell until the battery acid reaches the level specified by the 3 4 battery manufacturer Do not overfill For a battery without removable cell caps such as valve...

Page 6: ...cted to the chassis vehicle 6 4 frame If the negative post is grounded to the chassis as in most vehicles see step 6 5 If the positive post is grounded to the chassis see step 6 6 For a negative groun...

Page 7: ...cting 7 7 procedure and break the first connection while as far away from the battery as practical A marine boat battery must be removed and charged on shore To charge it onboard 7 8 requires equipmen...

Page 8: ...activity on the meter although the meter does not have the resolution to display this low rate For the 2 amp charge rate a triangle has been provided Its accuracy has been calibrated for use with sma...

Page 9: ...anking Amps RC Reserve Capacity AH Amp Hour NR means that the charger setting is NOT RECOMMENDED Find your battery s rating on the chart below and note the charge time given for each charger setting T...

Page 10: ...ery is defective will not accept a charge 2 amp charge rate is being used Plug the charger into an AC outlet Check for open fuse or circuit breaker supplying AC outlet Check power cord and extension c...

Page 11: ...normal condition BEFORE RETURNING FOR REPAIRS 16 When a charging problem arises make certain that the battery is capable of accepting 16 1 a normal charge Double check all connections the AC outlet f...