Dieffematic PROXMINI Quick Start Manual Download Page 2

- iQ-1000  CONTROL BOARD  FOR 230 VAC ROLLING SHUTTERS

The electronic control board (with built in receiver) for rolling shutters,

PROXMINI

, is suitable for

rolling shutters controlled by single phase 230 V AC current with built in limit switches, to shut
power down before the 2 minute safety operation time has elapsed (after which the control board
automatically stops).

Basic Characteristics

Ÿ

  Max motor power:  300 Watt  / 230VAC

Ÿ

  Built in  433.92 MHZ RF Receiver, rolling code (30 remote controls).

Ÿ

  Button command input.

Ÿ

  2  minutes max limit switch off time (for safety reasons in case of limit switch failure)

Ÿ

  Does not support photocells or automatic motor limit switch power off recognition

Ÿ

  Intended for small domestic rolling shutters with 230 VAC power supply operation.

Ÿ

  Easy remote control programming and control board connectivity.

Ÿ

Compact design. Size: 44x44x25 mm

Connectivity

230VAC

Power

supply

M

2~

BUTTON

L

N

23

0VA

C/

ma

x5

00

W

Auto  Learn

WARNING

230Vac

c

Push

5

i

Q

1000

Button

command

ATTENTION !!!

BUTTON operates

with 230 VAC.

Store code from compatible remote control to receiver

To begin programming a remote control, we press  Auto Learn button. It is located on the upper right corner
of the board.

Store code

Press and release Auto Learn

once.

The LED stays steadily on for 10 sec.
During these 10 seconds we press the remote control we want to programm

For additional remote controls repeat the procedure
If the control board has already 30 remote controls stored, every new one deletes the older one.

DELETE ALL sored remote controls.

Depress and hold Auto Learn for 10 seconds and the LED starts blinking. all stored remote controls are
removed and the
control board’s memory is erased.

M

2~

BUTTON

L

N

23

0V

AC

/m

ax

50

0W

Auto  Learn

WARNING

230Vac

c

Push

5

i

Q

1000

Antenna

Size in mm

ATTENTION

The Product must be installed by qualified personnel who can carry out the installation operation strictly in compliance with safety rules. The device must not be used
incorrectly or for any purposes other than the ones designed for. Before proceeding with the installation it is necessary to read the instruction manual carefully in
order to avoid danger to either the users or the equipment. It is necessary to power the device using a 6A bipolar thermomagnetic switch equipped with a differential
with an operating current of 0.03A. Before currying out any installation or maintenance operations turn off the power supply to the device with the bipolar switch. The
equipment must not be tampered with or modified in any way. it is necessary to turn off the power supply to the equipment before installing it or opening the
enclosure.

The manufacturer reserves the right to make changes to the product without  prior notice. Therefore this manual may not correspond exactly to the
product specifications.

Single phase motor

COMUN

OPEN/CLOSE

OPEN/CLOSE

Line
Neutral

DIEFFEMATIC   -  VIA MAZZINI, 51

66020 San Giovanni Teatino (CH)

TEL/FAX 085 2190140

email:

[email protected]

 - web:

www.dieffematic.it

Reviews: