rev. 1.0 06/03/2018
CENTRALE Mini
S-0205-00
FW 3.0.5
IMPORTANT WARNINGS
The manufacturer from now declines all responsibility for damage to persons
or things due to improper use of the device, failure to comply with the
instructions herein, incorrect installation or any damage if the electrical
system upstream of the automation does not comply with current regulations.
NOTE:
Non The centre must not have any type of sectioning
mechanism from the electrical line 230 Vac; it is therefore
the responsibility of the installer to see the installation of
a sectioning device within the plant.
The correct functionament of S-0205-00 anticipates the
connection of a general safety device with contact (NC).If
not used, this input must be bridged.
Mono-phase electronic exchange, for the automation of
sliding doors and rolling shutters with an incorporated
radio receiver.
Installation must be performed by qualified technical personnel. Similar
considerations apply to the planning phases and to any necessary maintenance
operations that may be necessary.
COLLEGAMENTI:
MT1
1.
230 Vac input (phase)
2.
230 Vac input (Neutral)
3.
Opening motor output
4.
Common motor output
5.
Closing motor output
6.
Command output for anti-tampering device ("Central MAXI") (device sold
separately).
7.
230 Vac flash input (Phase)
8.
230 Vac flash input (Neutral)
MT2
A. 12 Vac 1 W service feed output.
B. 12 Vac 1 W service feed output.
C. Open-close push button input (NA).
D. Common GND input.
E. Safety device input (NC).
OPERATIONS:
Operation Step-by-Step:
(REMOTE CONTROL 2 buttons)
The first pulse (by radio control) controls the opening until the operating time lapse; the second
impulse closes the shutter. If a button is pressed before the operating time expires, the control unit
will stop the motion, a further command restarts motion in the opposite direction.
Operation Step-by-Step:
(
REMOTE CONTROL 1 button,
or low tension button)
The pulse (by radio control or low voltage button) controls the opening until the operating time lapse;
the second impulse closes the shutter. If the button is pressed before the operating time expires, the
control unit will stop the motion, a further command restarts motion in the opposite direction.
Automatic Closing:
The control unit can close the rolling shutter (when the opening limit switch) automatically without
sending additional commands. The choice of this mode of operation is described in the programming
mode of the automatic closing time.
Security Device:
The control unit allows the supply and connection of photocells, pneumatic edge. The intervention
in the opening phase is not considered, in the closing phase causes the reversal of the motion. This
input
(MT2: C-D)
if not used must be bridged.
PROGRAMMING THE DEVICE:
Use the
SEL
and
SET
keys of the control unit to enable or disable, program a series of functions
and parameters as listed in the table below.
SEL:
Selects the type of function to be memorized, the selection is indicated by a flashing Led. By
repeatedly pressing the button it is possible to choose the desired function (
7 led
). The
selection will remain active for 10 seconds indicated by a flashing Led, if no other operations
are executed during this period, the control board will return to its previous state.
WARNING:
During programming, the control panel does not respond to
commands from remote control or low voltage button.
LED N°
DESCRIZIONE
F1
Storing codes Transmitter
CODE
F2
Operating time programming
MOTOR TIME
F3
Automatic closing time
T. PAUSE
F4
“User Present” CLOSE
UOMO/CH
F5
“User Present” OPEN
UOMO/AP
F6
Buzzer enabling
BEEP
F7
Courtesy-Flashing Light
LAMP/CORT
F8
End Run Position.
FC
SET:
programmes the information relative the type of function previously selected with the
SEL button.
Functions with one or two remote control commands
(funz.
CODE
)
It is possible to memorise one or two remote control commands during the programming stage. One
code can be used for a cyclical function (raising/lowering), whilst two different codes allows different
commands, the first for raising and the second for lowering.
With remote control to a single key or the low tension button panel, you will get
the following operation:
By using either the radio control or the low tension button panel to operate the gates, commands will
have the following effect: The first command impulse activates the opening mechanism until time
expiry of the timing motor, the second command impulse closes the gate, if a command impulse is
received before the time expiry of the timing motor, the direction of movement of the mechanism will
be halted.
An additional input determines the restart of the movement in the opposite direction.
Using a remote control with two keys, you will get the following operation:
The first button activates the opening mechanism until time expiry of the timing motor, the second
button closes the gate, if a command impulse is received before the time xpiry of the timing motor,
the direction of movement of the mechanism will be halted.
A further input implements the re-starting of the motion in the opposite direction.
PROGRAMMING:
The transmission code is programmed in the following manner: press the
SEL button
until the
LED
F1
CODE
flashes, immediately transmit the pre-selected code with the desired remote control, as
soon as the
LED
F1
CODE
begins to flash rapidly send the second code to be memorised, when
the
LED
F1
CODE
remains lit, the programming is complete. If the second code is not sent within
10 seconds
the control unit will exit the programming phase and select the function with only one
code of the remote control.
CANCELLAZIONE TELECOMANDI:
To cancel all stored codes press the
SEL
button and
LED
F1
CODE
will start to flash. Then
press the
SET
button for 10 seconds The procedure is now complete and
LED
F1
CODE
will stop flashing. (The acoustic signal indicates the success of the operation).
Note:
When
75 codes
have been stored all LEDs will flash, indicating that no other codes can be
stored.
Engli
s
h
1 2 3 4 5 6 7
8
MT 1
MT 2
A B C D E