5.12.9 Ramps
Options
Description
Acc Open
The ramps change the speed at which the motor reaches its operating speed.
The higher the value, the faster the motor changes to the intended operating
speed. This parameter is used when the door is opened.
Acc Close
The ramps change the speed at which the motor reaches its operating speed.
The higher the value, the faster the motor changes to the intended operating
speed. This parameter is used when closing the door.
Dec Open
Ramp-down deceleration is used when the door opens and stops to reach the
fully open position.
Dec Close
Ramp-down deceleration is used when the door closes and stops to reach the
fully closed position.
Dec Stop
Open
When the door opens and the Stop button is activated, it stops depending on the
value set for this parameter. This parameter should be set to stop the door without
excessive force on the drive mechanism.
Dec Stop
Close
When the door closes and the Stop button is activated, it stops depending on the
value set for this parameter. This parameter should be set to stop the door without
exerting excessive force on the drive mechanism.
Dec
Emergency
When the door closes and the safety edge is activated, it stops depending on
the value set for this parameter and then reverses. This parameter should be set so
that the door stops quickly and the closing force is not exceeded.
5.12.10 Special features
Special features
Description
Move
Assist
OFF
Deactivation of the “Move assist“ help function.
OPEN
“Move assist“ detects the manual movement of the door and starts to
open/close the door at “Dead-man“ speed. Set the direction for support.
CLOSE
OPEN/
CLOSE
Move Assist Sens.
Adjusts the sensitivity of the “Move assist“.
Delta Slip
Adjusts the sensitivity of the “Delta slip“ measurement. Set the percentage
of “Delta slip“ allowed before setting the slip error.