background image

© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany

Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 1067

Electromagnets

Page 07.032.00

ø 40

23

ø 60

ø 48

67

10

7

ø 96

88

 "L"

"M"

 8

8

70

68

7 x 1

0

3

40

ø 1

8

Ar

re

tierschr

aube

You can either fix the electromagnet with swivel head to the floor, ceiling or wall. If you 

want to change the position of the head, you need to loosen the locking screw and turn 

the head by 90°.
If you need to cut the distance tube, remove the head after loosening both grub screws 

which fix the head to the tube. Then pull out the wires connected to the interruption key. 
An anchorplate needs to be fixed to the door as a counterpart to the magnet. A choice 

of different counter plates can be found later in this section.
The connection wires are inserted through an opening in the mounting plate. After the 

magnet has been properly mounted and wired, both plastic covers are pushed from the 

side over the mounting plate and clipped into position.

Please note:

It must be possible to release a fire protection door held open by an electromagnet with 

a hand switch which is not hidden by the opened door. (DICTATOR hand switch part no. 

040005, see diagram on the left).

Installation

Order Information

Dimensions

Locking screw

Model

Force

Length "L" Height "M" Part no.

GD 60 S 175

700 N

175 mm

107 mm

040111

GD 60 S 175 oT (ohne Taster = 

without interruptor key)

700N

175 mm

107 mm

040264

GD 60 S 175 S

1000 N 175 mm

107 mm

040164

GD 60 S 325

700 N

325 mm

257 mm

040112

GD 60 S 475

700N

475 mm

407 mm

040113

Reviews: