background image

Dickson TH8P Manual V14 052418 

DICK

DICK

DICK

DICKSON 

SON 

SON 

SON     

    

    

    

    

    

    

      

      

      

      TH8P0/2/3/5

TH8P0/2/3/5

TH8P0/2/3/5

TH8P0/2/3/5    

    

    

    

    

    

    

      

      

      

             

       

       

       Temperature & Humidity Recorder

Temperature & Humidity Recorder

Temperature & Humidity Recorder

Temperature & Humidity Recorder    

GETTING STARTED

GETTING STARTED

GETTING STARTED

GETTING STARTED    
7-day chart rotation 
+32 to 120

o

F (TH8P0/2) 

-20 to +120

o

F (TH8P3/5) 

 
QUICK START

QUICK START

QUICK START

QUICK START    

1.

1.

1.

1.

 

Remove the protective pen caps. 

 

2.

2.

2.

2.

 

Check to make sure the Replaceable Sensor is connected firmly to the recorder.  If using 
model TH8P3/5 make sure the extension cord is connected firmly to the recorder and 
that the Replaceable Sensor is plugged in firmly to the extension cable.  

 

 

3.

3.

3.

3.

 

Insert batteries and plug in AC adapter (See Figure 3).  TH8P0:4 AA batteries required; 
TH8P2/3/5: 4 AA batteries backup power only (See Power section for backup life).  Unit 
will power on. 

 

4.

4.

4.

4.

 

The instrument will move pens to the appropriate readings. 

 

5.

5.

5.

5.

 

Install the chart that matches the Dip Switch settings (See Dip Switch Setup). 
 
Press the PEN HOME

PEN HOME

PEN HOME

PEN HOME key to move the pens to the outside of the chart.  The pen is 

automatically raised off the chart. 
 
Remove the old chart, place the new chart on the Chart Hub being certain that the edge 
of the chart slides under the Chart Guide Clips located at the outside of the chart. 
 

6.

6.

6.

6.

 

Set the appropriate time.  There are two ways to adjust the chart and set the appropriate 
time: 

 

a.

 

Set the chart time manually by inserting a coin into the groove in the chart hub 
and turning clockwise until the correct hour (and day if applicable) on the chart is 
referenced to the timing arrow (just to the right of the pen tip on the dial).  Press 
Pen Home

Pen Home

Pen Home

Pen Home to move the pens back onto the chart. 

 

The following feature should be used for fine adjustments only. 

 
b.

 

To adjust the chart time, press and hold Adjust

Adjust

Adjust

Adjust----Up

Up

Up

Up and Adjust

Adjust

Adjust

Adjust----Down

Down

Down

Down buttons 

located on the back of the unit next to the dip switch (see Figure 3). 

 

The green LED will blink rapidly for about five seconds, then the LED will remain 
solid green.  While in this state the Adjust

Adjust

Adjust

Adjust----Up

Up

Up

Up button will move the chart 

backward (counter clockwise) and the Adjust

Adjust

Adjust

Adjust----Down

Down

Down

Down button will move the chart 

forward (clockwise). 
 
Rotate the chart until the correct hour (and day if applicable) on the chart is 
referenced to the timing arrow.  Once you have set your chart, press the Pen 

Pen 

Pen 

Pen 

Home 

Home 

Home 

Home button to exit Chart Adjust Mode.  The unit will take one minute to exit the 
Chart Adjust Mode once Pen Home

Pen Home

Pen Home

Pen Home is pressed.  Press Pen Home

Pen Home

Pen Home

Pen Home to move the pens 

back onto the chart. 
 

c.

 

Place the TH8recorder on a flat vibration-free surface.  Be sure it is in a vertical 
position and level.  For best performance and longevity, the location should be a 
clean environment, free from dust and corrosive fumes.  Do not exceed 
temperature specifications.  Wall Mount:  Keyhole slots are provided on the 
TH8recorder for wall mounting. 

 

Summary of Contents for TH8P0

Page 1: ...a Set the chart time manually by inserting a coin into the groove in the chart hub and turning clockwise until the correct hour and day if applicable on the chart is referenced to the timing arrow jus...

Page 2: ...ed on the outside edge of the chart press the Pen Home Pen Home Pen Home Pen Home to move pen s to recording position If the pens are located on the chart press the Pen Home Pen Home Pen Home Pen Home...

Page 3: ...n will scroll through the five options until the A A A Alarm larm larm larm button is pressed to exit from alarm adjust Each press of the Pen Home Pen Home Pen Home Pen Home or Alarm Alarm Alarm Alarm...

Page 4: ...Use a Pen or small screw driver to flip the switches Remember to install the correct chart to match the corresponding Dip Switch setting Re Re Re Recording Time cording Time cording Time cording Time...

Page 5: ...s over time 1 While the unit is on press and hold both Pen Home Pen Home Pen Home Pen Home and On Off On Off On Off On Off buttons until the LED is solid green Release the Pen Pen Pen Pen Home Home Ho...

Page 6: ...th the On Off On Off On Off On Off and the Adjust Adjust Adjust Adjust Down Down Down Down button until the LED is solid green The LED will then blink amber at which point only the pen being adjusted...

Page 7: ...al Why does the display read PROB Why does the display read PROB Why does the display read PROB Why does the display read PROB Check the TH sensor pod Make sure it is properly plugged into the unit Is...

Page 8: ...won t the unit power up Remove the batteries and power adapter for a minute or two this will reset the unit The unit should respond when the adapter is plugged in WARRANTY WARRANTY WARRANTY WARRANTY D...

Page 9: ...The Replaceable Sensor must be connected to the Instrument for the Instrument to operate properly Calibration Calibration Calibration Calibration Only the Replaceable Sensor is calibrated The sensor...