background image

Dickson KT8P Manual V6 52418 

DISPLAY SYMBOLS 

DISPLAY SYMBOLS 

DISPLAY SYMBOLS 

DISPLAY SYMBOLS KT8

KT8

KT8

KT8P

P

P

P    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BUTTON OPERATION

BUTTON OPERATION

BUTTON OPERATION

BUTTON OPERATION    

    

    

    
    
On/Off

On/Off

On/Off

On/Off    
The On/Off key turns the unit on and off. 
 
Pen

Pen

Pen

Pen    Home (Down Arrow)

Home (Down Arrow)

Home (Down Arrow)

Home (Down Arrow)    

If the pen(s) are located on the outside edge of the chart, press the Pen

Pen

Pen

Pen    Home

Home

Home

Home to move pen(s) to 

recording position. If the pen(s) are located on the chart, press the Pen

Pen

Pen

Pen    Home

Home

Home

Home key to move the pen(s) to 

the outside edge of the chart. 
    
A

A

A

Alarm 

larm 

larm 

larm ((((Optional

Optional

Optional

Optional))))    

Pen 1: = Red Pen 
Pen 2: = Blue Pen 

 

 

 

Channel Indicator 

Low Battery Indicator 

Unit of Measure 
for channel 
displayed: F, C  

Current Reading or Flashing 
“ALRN” when in alarm 
condition. 

Displays when 
setting alarms. 

Summary of Contents for KT8P0

Page 1: ...t time manually by inserting a coin into the groove in the chart hub and turning clockwise until the correct hour and day if applicable on the chart is referenced to the timing arrow just to the right of the pen tip on the dial Press Pen Pen Pen Pen Home Home Home Home to move the pen s back onto the chart The following feature should be used for fine adjustments only b To adjust the chart time pr...

Page 2: ... the pen s are located on the outside edge of the chart press the Pen Pen Pen Pen Home Home Home Home to move pen s to recording position If the pen s are located on the chart press the Pen Pen Pen Pen Home Home Home Home key to move the pen s to the outside edge of the chart A A A Alarm larm larm larm Optional Optional Optional Optional Pen 1 Red Pen Pen 2 Blue Pen F Channel Indicator Low Battery...

Page 3: ...en Pen Pen Home Home Home Home button will scroll through the five options until the A A A Alarm larm larm larm button is pressed to exit from alarm adjust Each press of the Pe Pe Pe Pen n n n Home Home Home Home or Alarm Alarm Alarm Alarm button will store the new settings The unit will take one minute to exit Alarm Set Mode once the Alarm Alarm Alarm Alarm button is pressed 4 4 4 4 If the alarm ...

Page 4: ...ng Time 1 down 2 up 1 down 2 down 1 up 2 up o F 3 down o C 3 up Temperature Ranges Temperature Ranges Temperature Ranges Temperature Ranges 4 down 5 down 6 down 4 down 5 down 6 up 4 down 5 up 6 up 4 up 5 down 6 down 4 down 5 up 6 down 4 up 5 up 6 up 4 up 5 down 6 up 4 up 5 up 6 down All the KT8 recorders feature usre selectable recording times Note Remember to install the correct chart to match co...

Page 5: ...n Home Pen Home Pen Home Pen Home and On Off On Off On Off On Off buttons until the LED is solid green Release the Pen Home Pen Home Pen Home Pen Home and On Off On Off On Off On Off buttons The LED will flash amber and green for one second then the LED will turn off Note Note Note Note Press Pen Home Pen Home Pen Home Pen Home first so the unit will not turn off 2 The pen s will move to the outer...

Page 6: ...T856 calibration can be adjusted at one point This will not adjust the span and is not as accurate as replacing the Replaceable Sensor with a newly calibrated one or returning the KT856 for recalibration 1 To activate Calibration mode turn the unit on and press and hold both the On Off On Off On Off On Off and the Adjust Adjust Adjust Adjust Down Down Down Down button until the LED is solid green ...

Page 7: ...her range or vice versa Pen s not inserted on pen arm s all the way To adjust pen s to match chart see Pen Home Adjust in the Need to Know section of this manual Why does the display read PROB Why does the display read PROB Why does the display read PROB Why does the display read PROB Check the sensor pod and KTC probe s Make sure it is properly plugged into the unit Is the unit locked up This can...

Page 8: ...l number serial number and a PO number ready before calling Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Dickson ensures that the Replaceable Sensors Instruments listed below were developed tested and validated together Replaceable Sensor Model R400 Instrument Mode...

Reviews: