M A L F U N C T I O N TA B L E
EN
DiBO
23
Malfunction table
At a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a DiBO technician and/or
a recognized DiBO representative.
Technical info
GENERAL
In this chapter you find the most important technical data of the range where
your machine belongs. Machine statement see chapter
“Technical data” on
page 25
.
GENERAL DATA
• Maximum reactive force of the sprinklers: < 60N
• Minimum water pressure (at LP entry): 200 kPa (2 bar)
• Maximum water pressure (at LP entry): 300 kPa (3 bar)
• Minimum water temperature: 1 °C
• Maximum water temperature: see
“Technical data” on page 25
• Sufficient water supply at drinking water quality (Directive 98/83/EG)
• The vibration intensity through a lance with normal nozzle: exceeding the
action value of 2.5 m/s² is unlikely, the limit value of 5 m/s² on a daily basis will
not be exceeded.
• The use of an extra water filter is recommended
• Fill with clean, fresh unleaded fuel, a minimum of 87 octane/87 AKI or higher -
RON: min. 90. (with up to 10% ethanol (gasohol) - 90% lead-free is acceptable),
preferable E5 or E10 gasoline/petrol fuel.
ACCESSORIES
1 x user manual
MALFUNCTION
CAUSE
SOLUTION
Machine does not start
• Battery tension too low
• Operation switch “OFF”
• Start engine does not work
• Too few oil in engine casing
• Is the fuel valve ON?
• No fuel in the fuel tank
• Rest malfunctions
• Loads battery
• Operation switch “ON”
• Consult an expert
• Refill oil
• Put the fuel valve on “ON”
• Refill with fuel
• Consult an expert
No water pressure
• To few water inlet
• Filter stuffed-up
• Repair water inlet
• Clean/replace filter cartridge
Instable and to weak pressure
• Air in water supply (leaks in water
supply)
• Nozzle or lance stuffed-up or worn-
out.
• Pressure regulator defect
• Rest malfunctions
• Put machine completely without
power! Repair leaks in supply.
• Clean or replace
• Consult an expert
• Consult an expert
HP pump pulse
• Leak or congestion in supply
conduit
• To much air present
• Clean/replace/repair
• De-aeration of cleaner