Specifications 

 

 

Model 

SSE-006 

Flow rate at 94% UVT 

@30mJ/cm2, 0.5GPM at max., @40mJ/cm2, 0.3GPM at 
max. 

SS304 chamber size 

260mm length, 50.8mm diameter 

Grounding wire 

NO 

Inlet/outlet port size 

1/4" female thread 

Voltage 

220-240V 50/60Hz 

Lamp power 

6w 

Max. working pressure 

8 bar 

Ambient water temperature 

2-40

 

Visual & audible lamp alarm 

YES 

Visual power on 

YES 

Lamp replacement reminder 

NO 

Lamp working life reminder  

NO 

 

UV LAMP 

Power 

6w 

Diameter 

15mm, T5 
type 

Installation available 
length 

212mm  

Current 

0.425A 

Voltage 

20V 

uvc intensity @254nm  

22uW/cm2 

Working life 

8,000 hours 

 

7.

 

Content of kit 

 

 

 
 

 

Quartz sleeve 

UV Lamp 

Reactor chamber 

Electronic 

Ballast 

Support, O-ring 

and fitting 1/4° 

Teflon 

Summary of Contents for SSE-006

Page 1: ...ons The assumption is made that before making an attempt to operate the device the operator is familiar with the operation of the water sterilizer and has read its Operator s Manual Importer DiaSysTechnologies 1682 rue de la Valsiere 34790 GRABELS FRANCE FieldService ContactyourlocalDiaSysDiagnosticrepresentativeforsupport DiaSys Technologies DiaSys Diagnostic Systems are registered trademarks of ...

Page 2: ...to power c Do not proceed to install the equipment when UV Lamp or Sleeve Tube is broken buy one again and continue d Ultraviolet Disinfection System is designed for continuous operation and frequent switching will reduce Ultraviolet radiation and service life But if you do not use the equipment for a long time you can turn off the power and water supply to save energy e If this unit falls into th...

Page 3: ...t size 1 4 female thread Voltage 220 240V 50 60Hz Lamp power 6w Max working pressure 8 bar Ambient water temperature 2 40 Visual audible lamp alarm YES Visual power on YES Lamp replacement reminder NO Lamp working life reminder NO UV LAMP Power 6w Diameter 15mm T5 type Installation available length 212mm Current 0 425A Voltage 20V uvc intensity 254nm 22uW cm2 Working life 8 000 hours 7 Content of ...

Page 4: ...ctor Chamber To protect the O ring do not over tighten Step 7 Connect 4 pin Electrical Socket with UV Lamp pins tightly Step 8 Carefully insert the UV Lamp into the Quartz Tube through End Nut Step 9 Install the Cover Cap and hand tighten onto End Nut Step 10 Select a readily accessible and well lit location to fix the system The system should always be located closest to the point of use and can ...