External Control
RS232 control is not necessary for operation but is a convenient way to control displays from a computer at
a distance. Most functions that can be done with the remote, can also be done with RS232 commands.
RS232 Command Format
Commands sent from an automation/control system or PC to the display must have the following format:
STX
(1byte) +
IDT
(1byte) +
Type
(1byte) +
CMD
(3bytes) +
[Value/ Reply (1byte)]
+
ETX
(1byte)
STX
:
Start byte =
07
IDT
:
Don’t care
Type
:
Read or Write command,
01
: read,
02
: write;
00
: return to host (from monitor)
CMD
:
as following tables
Value
:
Setting Value of “Write Command”
Reply
:
Return Value of monitor
ETX
:
End byte =
08
Transmit from PC (Host)
Read command
:
07 IDT 01 CMD 08 (7bytes)
Write/Setting command
:
07 IDT 02 CMD VAL 08 (8bytes)
Return from Monitor:
Return CMD is the same with received CMD, the return command will be sent after action.
Serial Port Setting
Baud Rate
Data Bit
Parity Bit
Stop Bit
115200
8
None
1
Baud rate can be set to 115200, 38400, 19200, or 9600 to match the monitor baud rate setting.
Baud rate 115200 is the default setting.
Explanation of symbols
▲: Valid command on Power saving/ off mode (The setting of "Power Saving Config" must
not be “Eco”).