1 / 32
250S-UK1.DOC
DIA-250
/
DIA-376
DIA-245
T
ELEPHONE
U
SER GUIDE AND INSTALLATION MANUAL
FLUSH
-
FITTING OR INTEGRATED
Page 1: ...1 32 250S UK1 DOC DIA 250 DIA 376 DIA 245 TELEPHONE USER GUIDE AND INSTALLATION MANUAL FLUSH FITTING OR INTEGRATED...
Page 2: ...NSTALLATION OF DIA 250 S 11 2 2 DIA 250 S1 CL MOUNTING INSTRUCTIONS 12 2 3 INSTALLATION OF DIA 250 S 13 2 4 DIA 250S1 CLD MOUNTING INSTRUCTION 14 3 LAYOUT OF THE TELEPHONE CARD 15 3 1 FUNCTIONS AND JU...
Page 3: ...R SENTATION 1 1 TELEPHONE TYPES FLUSH FITTING WEATHERPROOF HANDS FREE TELEPHONE WITH KEYBOARD FOR CLEAN ROOM DIA 250 See page 8 INTEGRATED WEATHERPROOF HANDS FREE TELEPHONE WITH KEYBOARD FOR CLEAN ROO...
Page 4: ...IN THIS MANUAL NO GUARANTEE CAN BE INVOKED IF DETERIORATION RESULTS FROM AN EXTERNAL SOURCE OR FROM LACK OF ADHERENCE TO INSTRUCTIONS FOR USE IN THE DESIRE FOR CONTINUAL IMPROVEMENT THE INFORMATION CO...
Page 5: ...pped with A weatherproof loudspeaker A weatherproof Electret type microphone An electronic circuit card An on line LED A keypad with function keys FEATURES Pulse Tone dialing Automatic clear down capa...
Page 6: ...IGURED FOR NORMAL USE BEFORE INSTALLATION READ THIS MANUAL CAREFULLY TO BE SURE THE FACTORY SETTING SUITS THE DESIRED USE The Hands free telephones operate without any modification to PSTN circuits Fo...
Page 7: ...etection time 4 10 sec Beep 100 to 600 ms Pause 100 to 600 ms Distance ringing tone Frequency 350 500Hz Beep pause sequence until far end off hook Beep 0 2sec to 1 6 sec Beep pause sequence 6 sec End...
Page 8: ...S ACB type flush fitting telephone set with weatherproof faceplate IP65 comprising a painted steel plate backing case and a stainless faceplate with a self adhesive polyester plaque with integrated ke...
Page 9: ...h fitting telephone set with weatherproof faceplate IP65 comprising a painted steel plate backing case and a stainless faceplate with a self adhesive polyester plaque with integrated keypad to be stuc...
Page 10: ...rogramming 10 direct memory access for keys 0 to 9 is allowed see chapter autodial numbers M0 to M9 page 22 Remotely checked phones 8 memories M1 to M8 available by pushing keys 1 to 8 without pushing...
Page 11: ...INSTALLATION OF DIA 250 S 152 165 4 COUNTERSUNK HOLES Diam 3 5 DRILLED AT 90 4 HOLES diam 11 216 252 100 CUT OUT PLAN FOR INSERTION INTO A PANEL Cut out the panel according to measurements below PART...
Page 12: ...cording to measurements below PARTITION SIDE 0 8mm MAX 2 Position the squares reference B behind the panel Fasten the screws reference 1A matching the holes in the sides with those in the panel 3 Pass...
Page 13: ...OC 2 3 INSTALLATION OF DIA 250 S R 2 5 180 245 90 76 52 51 3 37 165 260 HOLE Diam 15 4 HOLES Diam 3 5 DRILLED AT 90 HOLE Diam 80 CUT OUT PLAN FOR INSERTION INTO A PANEL Cut out the panel according to...
Page 14: ...e 2 Fasten the face plate on to the panel using countersunk screws 3 Place the keypad ribbon cable in the face plate slot then fasten the plaque Connect the ribbon cable to connector P4 of the telepho...
Page 15: ...PER SETTINGS FUNCTIONS REPAIRS JUMPERS SENSITIVITY OF THE HANDS FREE MICROPHONE Sensitivity up to 1m Sensitivity up to 30cm ST1 RECEPTION LEVEL ADJUSTMENT Minimum setting quiet location Maximum settin...
Page 16: ...onnection of the unit to the telephone line is carried out on printed circuit board WK140MLB with the plug in connector reference BR1 Connect the telephone line to the terminals L1 and L2 of the conne...
Page 17: ...ANSWER A CALL When the telephone rings The red indicator shows When the called party answers speak in front of the telephone from a distance of Approximately 20cm 8in At the end of conversation to fre...
Page 18: ...sh can be adjusted by programming The R button has a three functions according to the programming flashing or direct memory M1 see chapter programming page 22 or muting microphone If Direct Memory is...
Page 19: ...ogram the unit as following 24xx 0 Flashing time deactivated 32xx 99 going on hook by pressing a memory key a long time deactivated At the beginning of the communication microphone is activated By pus...
Page 20: ...g 1 to the first relay code value Keying this code on the keypad of a telephone equipped with a relay board will not activate its own relay In the factory setting the activation time of the relay is 2...
Page 21: ...peaker Voice is amplified by approx 20 Dba If 12V power supply is removed case 1 applies In case 1 and 2 jumpers ST1 and ST2 are in position 1 and ringing is not amplified 3 External 12 VDC power supp...
Page 22: ...e is a single beep if memory M0 see function 18 below is empty or a single beep followed by the contents of Memory 0 followed by if memory M0 has been programmed Non acceptance is indicated by no resp...
Page 23: ...WS SINGLE BUTTON TELEPHONE Program button N autodial number from 1 to 15 digits Program empty memory factory preset DUAL BUTTON TELEPHONE Program lower button N autodial number from 1 to 15 digits Pro...
Page 24: ...receipt of tone 04 5 Push to talk mode 08 Those values should be summed and the total applies e g 1000 1001 1007 pulse dialing no access to memory dialing no clear down on receipt of tone 3 LOUDSPEAKE...
Page 25: ...mories 2 and 3 for back up numbers Program the next memory in the example shown memory 4 as an empty memory Memory 5 is designated as the main number for the upper Button This is programmed in the sam...
Page 26: ...hone is set to answer automatically after 3 rings To change this number key NN 00 to 99 NN 03 factory setting answer automatically after 3 ring or manually by pushing the button NN 00 automatic answer...
Page 27: ...st not be the same value as the programming access code The remote command code is a 4 digit code To program it 2 actions are required Programming of thousands and hundreds identified below as T and H...
Page 28: ...D CONTINUOUSLY BEFORE TELEPHONE GOES ON LINE XX 00 Immediate factory setting XX 99 9 9 seconds 17XX 12 PASS CODE 1 First two digits of programming pass code XX 12 factory setting XX 10 range XX 99 30X...
Page 29: ...Hz 35XX 17 RETURN TELEPHONE TO FACTORY SETTING ERASE MEMORIES XX 00 Acknowledgement from telephone after about 1 3s XX 02 Erase memories M0 M9 98XX 18 PROGRAM TELEPHONE ID This is a code of up to four...
Page 30: ...of a call without access to programming the central system or operator can effect an automatic clear down by transmitting this code However if the call has included access to programming automatic cle...
Page 31: ...Before consulting the maintenance service we advise you to check the following points PROBLEM WITH LINE CONNECTION OR DIALLING Check telephone line correction on the connection terminal see page 16 TR...
Page 32: ...32 32 250S UK1 DOC...