Diamond AQUA 35 Instructions For Use And Installation Download Page 7

14 

SG03371 

9. ELIMINATION OF THE ELECTRIC AND ELECTRONIC WASTE 

 
The device respects the directives: 
 

2002/96/CE (DEEE) 

N°34270064800021 

2002/95/CE (ROHS) 
2066/95 CE 
2004/108 CE 

 
 

Reach rule 
 

Never put the device among household waste. 
The device must be put down in a centre of recycling for the electric equipments. 
 
The  materials  of  the  device  are  indeed  reusable.  By  eliminating  correctly  the  electric  and  electronic 
wastes, the recycling and quite other shape of re-use of worn equipments, you participate in a significant 
way in the environmental protection.  

 

For any information about the collection of electric and electronic waste, please contact your distributor. 
 
 

10. GUARANTEE 
 
Conditions of guarantee 

 
The  guarantee  applicable  to  any  device  is  the  commercial  guarantee  of  the  distributor  or  the  retailer. 
Please contact the store where you bought your device to know the precise conditions. 
 
The guarantee grants no right for damages. 
 
The dispositions which follow are not exclusive of the profit of the legal guarantee planned by articles 1641 
and following ones of the Civil code relative to the defects and the latent defects. 
 

Exclusion clauses of the guarantee 

 

Bad  installation  and  bad  maintenance,  in  particular  if  they  do  not  respect  current  regulations  or 
instructions appearing in this user guide. 

 

 

Cannot  benefit  from  the  guarantee  the  repairs  required  as  a  result  of  false  operations,  of  inappropriate 
use,  of  carelessness  or  of  excess  loads  of  the  device,  as  well  as  those  resulting  from  variations  of  the 
power supply, over tension or from defective installations. 
 
The damage due to shocks, bad weather is not flatware by the guarantee. The material travels at the risks 
of  the  user;  in  case  of  delivery  by  carrier,  the  consignee  has  to  have  reservations  towards  the  carrier 
before any delivery of the device. 
 
The guarantee comes to an end in case of intervention, of repair, of modification by no qualified persons, 
or of use in inappropriate purposes.

 

Summary of Contents for AQUA 35

Page 1: ...Mod CR 18S 35 Production code AQUA 35 12 2018 ...

Page 2: ...1 SG03371 INSTRUCTIONS FOR USE AND INSTALLATION DRINKING FOUNTAIN AQUA 35 Made in France ...

Page 3: ... without surveillance Never move the appliance when it is working Check that the appliance is definitely off before connecting it up or disconnecting it Do not use the appliance for other functions than determined use Do not leave the electrical cord in contact of hot surfaces The appliance should not be used close to combustible materials To avoid any electric shock never plunge the cord or plug ...

Page 4: ...ntilated condenser evaporator regulated through a thermostat Hydraulics a water jet tap equipped with an integrated regulator a filler glass a flow limiter Directly connected to the main water supply this drinking fountain provide a constant supply of chilled water 8 to 10 C Glass filler Water jet tap 1 2 1 2 ...

Page 5: ...ss Adjust the flow thanks to the visible adjusting screw on the back part of the fountain Adjust the flow of the water jet tap to have a suitable trajectory Switch on when there is no more air in the circuit Connection of the device Check that the tension and the frequency of the electricity network suit to the values indicated on the descriptive plate Check that neither the cord nor the plug are ...

Page 6: ... plug in the water or quite other liquid to avoid any electric shock Never use abrasive product to clean the stainless steel basin Proceed to a regular maintenance of the machine see 11 Maintenance recommendations 7 TECHNICAL SPECIFICATIONS Model AQUA 35 Outside dimensions 400 x 385 x 1245 mm Weight 32 Kg Compressor 0 28 kW Gas R 134 A Water temperature 8 à 10 C Current 2 5 A Voltage 220 240 V Wir...

Page 7: ... conditions The guarantee grants no right for damages The dispositions which follow are not exclusive of the profit of the legal guarantee planned by articles 1641 and following ones of the Civil code relative to the defects and the latent defects Exclusion clauses of the guarantee Bad installation and bad maintenance in particular if they do not respect current regulations or instructions appeari...

Page 8: ... Install opaque pipes and the shortest possible Cleaning and disinfection of the new parts see below Cleaning descaling and disinfection of the parts of the drinking fountain At least once a year and in case of abnormal results when control Disassemble the drinking fountain Descaling Make the descaling product circulate inside the evaporator Take off the parts that can be dismantled and immerse th...

Page 9: ... After not using more than 24 hours The duration of the purge depends on the length of the pipe in which the water stagnates during the night In practice the purge is performed when the water is at the temperature of use Surfaces extérieures grills et cuvette Cleaning Everyday Outdoor surfaces Cleaning with a detergent Rinse Avoid the use of abrasive products Grid and bowl Cleaning with a detergen...

Page 10: ...ler and basin Cleaning and disinfection Cleaning and disinfection 2 methods can be used 1st method Cleaning with a detergent Rinse Disinfection with chlorinated water at 6 chl time of contact 15 min Rinse 2nd method Cleaning and disinfection with a detergent and dissection solution time of contact according the recommendations of the product manufacturer Rinse Pipes and siphon Cleaning and disinfe...

Page 11: ...B10013 SH03011_1200 75057 SA03046 SA06043 SB10008 SH03018_1500 SB04066 SA13009 x4 G08102 SH03017 SB04070 SB10019 SB10021 SB10021 SB10030 SA03073 SF01057 SA03012 SA03090 75076 75058EV SB04064 SE02119 SB04065 Date 24 10 2018 Indice A Dessiné par R L Approuvé par AQUA 35 DT196 Date 24 10 2018 ...

Page 12: ...ERMOSTAT FONTAINE THERMOSTAT FOUNTAIN SA13009 4 VERIN HEXAGONE M8X20 VH 1000 HEXAGON JACK M8X20 SB04064 1 REGULATEUR DE DEBIT FONTAINE FLOW REGULATION SB04065 1 VIS DE REGLAGE DU REGULATEUR REGULATOR ADJUSTMENT SCREW SB04066 1 DESHYDRATEUR DEHYDRATOR SB04070 1 VALVE DE CHARGE 888 1 4 CHARGING VALVE 888 1 4 SB10006 1 ROBINET COL DE CYGNE FONTAINE WATER FILTER TAP DRINKING FOUNTAIN SB10008 1 ROBINET...

Page 13: ...20 SG03371 Schéma électrique Date 24 10 2018 Indice A Dessiné par R L Approuvé par AQUA 35 DT196 Date 24 10 2018 ...