Diamond +7ECED2R0N Manual Download Page 13

27

VI. MAINTENANCE

1. MAINTENENCE

All the components requiring maintenance are accessible
from the front of the appliance, after removing the control
panel and front panel. Disconnect the power supply before
opening the appliance

1.1 BRIEF TROUBLESHOOTING GUIDE

Even in normal appliance operating conditions, malfunctions
can occasionally occur.

-

The pilot burner of open burners does not light

Possible causes:

Insufficient pressure in gas pipes.

Nozzle blocked.

Faulty gas cock.

-

The oven pilot burner does not light

Possible causes:

Igniter not properly fixed or connected

The piezoelectric ignition or igniter cable are damaged.

Insufficient pressure in gas pipes

Worn nozzle

Faulty gas valve

-

The pilot burner goes out when the “pilot ignition” knob is
released

Possible causes:

The pilot bur ner is not heating the thermocouple
sufficiently.

Faulty thermocouple.

The gas cock and/or gas valve knob is not being pressed
enough.

Lack of gas pressure to the cock and/or valve.

Faulty gas cock or gas valve.

-

The pilot burner is still lit but the main burner does not light

Possible causes:

Loss of pressure in gas supply pipe.

Blocked nozzle or faulty gas cock or valve.

Gas outlet holes on burner clogged.

-

The oven temperature cannot be adjusted.

Possible causes:

Faulty thermostat bulb.

Faulty gas valve.

Faulty electric thermostat.

Electric safety thermostat tripped.

ABNORMAL OPERATION

Any of the following are considered to be abnormal operation

and may require servicing:

incomplete ignition of the burner;

yellow tipping of the burner flame;

burner failing to remain alight;

gas valves are difficult to turn;

burner exitinguished by operation of oven door.

In case the appliance fails to operate correctly, contact the

authorised service provider in your area.

INSTRUCTIONS FOR REPLACING COMPONENTS (to be
carried out only by an authorised installer).

Remove the front panel to access:

GAS COCK

Unscrew the pilot and thermocouple pipe, unscrew the
gas inlet and outlet connections.

For installation carry out the same procedure in reverse order.

PILOT BURNER, THERMOCOUPLE, IGNITER ASSEMBLY

To replace the igniter and thermocouple loosen the fixing
screws and remove the components.

To replace the pilot burner undo the gas pipe, remove the
pilot burner assembly

Replace the components, proceeding in reverse order to
refit the parts.

MAIN BURNER

Unscrew the gas connection from the nozzle holder

Undo the screws fixing the burner to the support

Remove the pilot burner assembly by undoing the screws

For installation carry out the same procedure in reverse order,
making sure that when positioning the burner the centering
pins, located at the back of the burner, enter their special seats

1.2 MAINTENENCE SCHEDULE

It is reccommended the appliance is inspected and
serviced by an authorized person at least every 12
months. For this purpose it is reccommended to draw up
a maintenece contract.

AUSTRALIA
For service and spare parts, please contact:

Electrolux - Tom Staddart Pty Ltd
Zanussi - JL Lennard Pty Ltd

Summary of Contents for +7ECED2R0N

Page 1: ...Mod E17 4PQF8 N Production code 373018 11 2011...

Page 2: ...NSTALLATION 19 1 REFERENCE STANDARDS 19 2 UNPACKING 19 3 POSITIONING 19 4 FUME EXHAUST AND VENTILATION 20 5 CONNECTIONS 21 6 SAFETY THERMOSTAT 22 7 BEFORE LEAVING 22 8 HANDRAIL 23 VI INSTRUCTIONS FOR...

Page 3: ...r supplyvoltage V 230 230 230 400 440 400 440 400 440 Phases N 3 3 3 3 3 3 3 3 3 Frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Cooktop hot plates 2 6 kW Nr 2 4 4 2 2 4 4 4 4 Cookt...

Page 4: ...it unless they are supervised or instructed in its use by a person responsible for their safety The appliance must be used by trained personnel Do not leave the appliance unattended when operating Tu...

Page 5: ...ocal gas fitting regulations municipal building codes electrical wiring regulations local water supply regulations AS5601 gas installation health authorites and any other statutory regulations 2 UNPAC...

Page 6: ...s The end of the exhaust pipe must be at least 1 8 m from the support surface of the appliance Note The system must ensure that a the fume exhaust is not obstructed b the length of the exhaust pipe do...

Page 7: ...stment of primary air supply to burner s pilot nozzle s replacement minimum flame screw s replacement correct adjustment pilot s if necessary correct adjustment of supply pressure see technical data g...

Page 8: ...acteristics at least equivalent to H05RN F rubber insulated type cables Protect the cable section outside the appliance with a metal or rigid plastic pipe 5 2 3 CIRCUIT BREAKER Install a circuit break...

Page 9: ...6 holes at points A For 1200mm and 1600mm appliances also drill at point B 8 1 2 ZANUSSI HANDRAIL Screw supports D on handrail C and insert them at the holes prepared Insert reinforcement plate R and...

Page 10: ...eate problems in combustion Before lighting the burners make sure the flame spreaders are turned to the stop position 1 2 ELECTRIC MODELS Equipped with rapid heating electric hot plates each of 2 6 kW...

Page 11: ...b I clockwise to position pilot Then press the knob down and turn it to position Off Note if removing knob L for cleaning always turn knob fully clockwise to the lowest setting and replace the knob so...

Page 12: ...affect the flame 2 OTHER SURFACES CAST IRON ELECTRIC HOT PLATES Clean the hot plates with a damp cloth then switch them on for a few minutes to dry rapidly lastly lubricate them with a light film of c...

Page 13: ...owing are considered to be abnormal operation and may require servicing incomplete ignition of the burner yellow tipping of the burner flame burner failing to remain alight gas valves are difficult to...

Reviews: