8
Basic Saw Operations
Removing and Installing Blade Drive Belt
WARNING; To reduce the risk of injury from unexpected
starting, unplug the saw whenever you are removing or
installing the Belt.
WARNING: Never use saw without Drive Belt Cover securely
in place
1. Unplug the saw from the outlet.
2. Remove Drive Belt Cover.
3. Loosen Motor Mount Bolts.
4. Pivot motor forward, and remove Drive Belt.
5. Replace Drive Belt, pivot motor backwards to tighten
Drive Belt.
6. Securely tighten Motor Mount Bolts.
NOTE: Drive belt tension-Drive belt should give
1/4” - 3/8” with moderate pressure.
7. Replace and securely tighten Drive Belt Cover.
Troubleshooting Guide
Motor
PROBLEM
PROBABLE CAUSE
SUGGESTED CORRECTIVE ACTION
Motor does not start.
1. Fuse.
- 15-Amp time delay fuse, or circuit
breaker.
2. Brushes worn.
- Get Authorized service.
3. Other.
- Get Authorized service.
Motor does not turn
1. Defective switch.
- Get Authorized service.
off/on.
General
PROBLEM
PROBABLE CAUSESUGGESTED CORRECTIVE ACTION
Blade binds, jams.
1. Dull blade.
- Replace blade.
2. Improper blade.
- Replace blade.
3. Warped blade.
- Replace blade.
Tool vibrates or shakes.
1. Saw blade not round.
- Replace blade.
2. Saw blade damaged.
- Replace blade.
3. Saw blade loose.
- Tighten Blade Retaining Nut
4. Other.
- Get Authorized service.
Your Power Miter II Saw is fully guaranteed for three years. If failure occurs for any reason other
than misuse during this period, it will be corrected free of charge when product is shipped to our
distribution center. Blades and Drive Belt wear even in normal use and cannot be guaranteed.
Diamond Tech International
5600-C Airport Blvd., Tampa, FL. 33634
HELPLINE (800) 937-9593
FAX:(813) 806-2923 • E-MAIL:[email protected] •
www.dticrafts.com
Diamond Tech International Warranty
Drive Belt