6. OUTPUT VOLTAGES AND CURRENTS 

Jupiter-MM-SIO provides either 4 output voltages. The outputs appear on the PC/104 bus headers J1 / J2 as well 
as on the auxiliary I/O connector J5. The table below lists the maximum ratings for each output voltage. 

 

Output 

Max Current 

Notes 

+5V 

10A 

Maximum rating achieved when 
only +5V output is used. Power 
drawn from additional outputs will 
reduce the available power on this 
line. 

+12V 

2A 

 

-5V 

0.1A 

 

-12V 

0.5A 

 

 

 

All outputs on the Jupiter-MM-SIO power supply are protected against overload on the outputs. The protection for 
each output circuit is slightly different: 

 

+5V 

Current limited to 10A. 

Above 10A the output voltage will drop to maintain maximum output of 50W. 

A short circuit will shut down the entire supply. 

+12V 

Current limited to 2A. 

Above 2A the voltage will drop to 5V and output current can increase to 10A (the 5V supply limit). 
Above 10A the output voltage will continue to drop. 

A short circuit will shut down the entire supply. 

-5V 

Current limited to 0.1A (100mA). 

A short circuit will shut down the output due to thermal protection in the output regulator IC. 

 

Note the four LEDs in the bottom left corner of the board. These LEDs indicate the status of the four output 
voltages. During normal operation all four LEDs should be lit with equal intensity. If any LED is not lit or is only 
dimly lit, a problem exists with that particular circuit. 

 

Summary of Contents for JUPITER-MM-SIO

Page 1: ...ly PC 104 Module With 2 RS 232 422 485 Serial Ports User Manual V1 3 Copyright 2001 DIAMOND SYSTEMS CORPORATION 8430 D Central Ave Newark CA 94560 Tel 510 456 7800 Fax 510 456 7878 techinfo diamondsys...

Page 2: ...6 SERIAL PORT CONNECTOR J6 7 4 SERIAL PORT CONFIGURATION 9 PORT AND INTERRUPT REGISTER ADDRESS SELECTION 9 SERIAL PROTOCOL SELECTION 9 CONFIGURATION FOR RS 422 AND RS 485 MODES 10 RS 422 RS 485 CABLE...

Page 3: ...anes as a heat sink High Efficiency High Frequency Design Efficiency is as high as 92 percent lowering input power requirements as well as heat generation The 200KHz switching circuit allows the use o...

Page 4: ...header J2 PC 104 16 bit bus header J3 Shutdown control J4 Main power input J5 Power input output connector J6 Serial port connector J7 J8 Serial port protocol configuration J9 Serial port address conf...

Page 5: ...or pins with power connections on board All remaining pins are not shown View from Top of Board J2 PC 104 16 bit bus connector J1 PC 104 8 bit bus connector Ground D0 C0 Ground A1 B1 Ground D1 C1 A2 B...

Page 6: ...ut Shutdown Control J3 Shutdown may be implemented by shorting the two pins on J3 together or driving a logic 0 into pin 1 1 Shutdown input 2 Ground Mating Connectors for J3 J4 and J5 The part numbers...

Page 7: ...llowing page for signal definitions RS 232 Configuration J6 DCD 1 1 2 DSR 1 RXD 1 3 4 RTS 1 TXD 1 5 6 CTS 1 DTR 1 7 8 RI 1 GND 9 10 NC DCD 2 11 12 DSR 2 RXD 2 13 14 RTS 2 TXD 2 15 16 CTS 2 DTR 2 17 18...

Page 8: ...eceive Data Input RTS Request To Send Output TXD Transmit Data Output CTS Clear To Send Input DTR Data Terminal Ready Output RI Ring Indicator Input RS 422 TXD TXD Differential Transmit Data Output RX...

Page 9: ...t the right edge of the board Eight different I O address combinations are selectable The address shown below for each port is the base address of that port i e the lowest address of the port s I O ad...

Page 10: ...ovided to select the interrupt level for each port from among levels 9 3 4 5 6 7 10 11 12 and 15 Install a jumper in the position corresponding to the desired interrupt level for each port A second ju...

Page 11: ...his port Default Settings The default settings for Jupiter MM SIO are as follows Protocol settings Both ports set for RS 232 protocol Jumpers 2 and 5 installed in locations J7 and J8 Address Interrupt...

Page 12: ...or to the Auxiliary connector J5 The supply will operate with input voltages from 7 to 30VDC CAUTION VOLTAGES ABOVE 31V WILL BE SHUNTED TO GROUND THROUGH THE TRANSIENT VOLTAGE SUPRESSOR TVS THE TVS I...

Page 13: ...ach output circuit is slightly different 5V Current limited to 10A Above 10A the output voltage will drop to maintain maximum output of 50W A short circuit will shut down the entire supply 12V Current...

Page 14: ...based on load and input voltage Serial Ports No of serial ports 2 Protocol RS 232 RS 422 RS 485 Jumper selected Maximum baud rate 115kbps standard version Parameters 5 6 7 or 8 data bits Even odd or...

Reviews: