DIAMOND DRYERS DIAMOND PLUS GWHD22 Installation Manual Download Page 6

HEATER SWITCH & QUIET (Q) MODE SWITCH

Heater Switch ON/OFF & Quiet Mode Switch (Factory default setting Heater “ON” / Quiet “OFF”)

9

ATTACHING UNIT

Reposition the front cover on the unit.

Insert and tighten two security screws into the front cover (fig. 8A).

Turn power switch “ON”

Test the unit for correct operation. The LED light on the cover should flash  times with a red light after 

the power supply has been correctly connected and followed by continuous light white LED.  

Note: If the LED light remains off, the unit must be refitted correctly.   

1. Turn power switch “OFF”.

2. Remove the two security screw on the front cover, using the service tool (fig. 2).

3. Lift the front cover off the unit (fig. 3).

4. To turn off or turn on heater, use the left switch shown in fig. 9.

5. To change Quiet mode, use the right switch shown in fig. 9.

7

EN

The unit has a built in UV-C lamp, avoid exposure to direct germicidal UV rays. 

Do not open the front cover before power off.

Note: Ensure the LED light on the front of the unit is OFF before opening the front cover, 

if the LED light is still ON, wait until the light goes off. 

 

Qmode

 On

1

 

Heat

 On

ON

ON

1

If the LED light on the front of the unit flashes red then the filter if fitted needs to be changed. The filter 

functions for approximately 60,000 operations.

1. Turn power switch “OFF”.

2. Remove the two security screw on the front cover, using the service tool (fig. 2).

3. Lift the front cover off the unit (fig. 3).

4. Turn the filter cover to open direction (fig. 10). The dot is aligned with the arrow present on the motor 

cover (fig. 10A-B).

5. Remove the filter(fig. 10B).

6. Insert the New filter. The dot on the filter cover is aligned with the arrow on the motor cover (fig.10C).

7. Turn the filter cover to close direction. The dot is positioned to the right of the arrow on the motor 

cover (fig.10A-A).

FILTER REPLACING

Summary of Contents for DIAMOND PLUS GWHD22

Page 1: ...DIAMONDPLUS...

Page 2: ...ed maintained repaired and removed by quali ed person s If the unit stops and works strangely contact your regional dealer or contractor This appliance can be used by children aged from 8 years and ab...

Page 3: ...If the unit is connected to any electrical supply other than stated on the rating plate of the unit permanent damage or unsafe operation of the unit may result The unit must be mounted on a at vertic...

Page 4: ...tions using 5 16 8mm drill insert the plastic anchors and tap flush to the wall If the cable entry is to be done from the wall provide a proper cable exit fig 5 8 5 5 EN 2 Positioning CAUTION Before i...

Page 5: ...As shown connect cable to terminal block and screw in terminal block 3 4 Fix the cable clamp with screw in the backplate fig 6A In case without built in power cable 6 CAUTION Connect the ground wire t...

Page 6: ...N The unit has a built in UV C lamp avoid exposure to direct germicidal UV rays Do not open the front cover before power off Note Ensure the LED light on the front of the unit is OFF before opening th...

Page 7: ...NING If the dryer has been fitted with a filter it will need to be replaced after 60 000 operations but will continue working for a further 15 000 operations but without the benefits of the HEPA filte...

Page 8: ...maintenance or repair 13 Regular maintenance Regularly clean the outer casing use a soft damp cloth to gently wipe away any dirt CAUTION Never use abrasives or chemicals to clean the cover Do not soa...

Reviews: