background image

 

 

      

 

DA16200 AT GUI Tool 

  

User Manual 

Revision 1.0 DRAFT 

03-Jul-2019 

CFR0012 

15 of 20 

© 2020 Dialog Semiconductor 

 

Figure 23:  Debug Console - AP Configuration 

 

● 

Configure DHCP server. Set IP addresses and click the Confirm button. When a client is 
connected, its MAC address will be shown as 

Figure 24

 

 

 

Figure 24:  DHCP Configuration 

 

 

Figure 25:  Debug Console - DHCP Configuration 

 

 

 

Summary of Contents for DA16200

Page 1: ...User Manual DA16200 AT GUI Tool...

Page 2: ...7 3 2 Board Connection 8 3 3 RF Certification Mode Setup 9 3 3 1 TX Test Mode 9 3 3 2 RX Test Mode 12 3 4 Network Mode Setup 12 3 4 1 Station Mode 13 3 4 2 AP Mode 14 3 5 OTP Mode Setup 16 4 Regulator...

Page 3: ...guration 9 Figure 10 Debug Console Tx mode 10 Figure 11 Start Stop Tx 11 Figure 12 Debug Console Start Tx 11 Figure 13 Debug Console Stop Tx 11 Figure 14 Rx Configuration 12 Figure 15 Network Mode Con...

Page 4: ...ous Receiver Transmitter SSID Service Set IDentifier DHCP Dynamic Host Configuration Protocol AP Access Point USB Universal Serial Bus MFC Microsoft Foundation Class References 1 DA16200 Datasheet Dia...

Page 5: ...The user just needs to connect with a micro USB cable and then two COM ports will be detected automatically If USB port is used install the FT232 Driver for windows In most cases it will be installed...

Page 6: ...uired to connect to the console of DA16200 Port Com port number on Windows system Baud rate 115 200 bps Data bits 8 bits Parity None Stop bits 1 bit Flow control None Figure 1 Terminal Configuration W...

Page 7: ...sing prompts when running this tool You need to install Microsoft Visual Studio redistributable package https www microsoft com en us download details aspx id 48145 or copy the dll file into the Windo...

Page 8: ...tected by the program press the R button to refresh COM Port Figure 4 RS232 Setup Disconnected Select a COM port and click the RS232 OPEN button Wait for a few seconds Connection status will be soon c...

Page 9: ...Certification Mode Setup To enable certification mode check on the mode option on the Chip Setting tab Figure 7 Certification Mode Configuration Alternatively on the Certification Mode tab Figure 8 C...

Page 10: ...er test and etc In this mode TX packet is generated continuously over 95 duty cycle CW mode Only single sinewave tone out mode This mode is for freq err check Data Rate Choose modulation type to test...

Page 11: ...tart TX Stop TX Figure 11 Start Stop Tx Tested setting is 802 11n MCS7 channel 1 100 bytes packet and power grade 0 When you click the Start TX button you can see messages as blow Figure 12 Debug Cons...

Page 12: ...st Mode RX Setting Channel Support CH1 CH13 Test Time Maximum 3600s Duration is 1 second fixed Figure 14 Rx Configuration RX Packet Rate FCS PHY Overflow packet Total packet Error rate 3 4 Network Mod...

Page 13: ...ck the Select button on the Mode Select option show in Figure 16 Network mode is changed DA16200 reboots and the station mode setup window will be shown as Figure 18 Figure 17 Debug Console Station Mo...

Page 14: ...20 Debug Console Connect to AP 3 4 2 AP Mode Choose the AP Mode and click the Select button on the Mode Select option then network mode is changed DA16200 reboots and the AP Mode setup window will be...

Page 15: ...0 2020 Dialog Semiconductor Figure 23 Debug Console AP Configuration Configure DHCP server Set IP addresses and click the Confirm button When a client is connected its MAC address will be shown as Fig...

Page 16: ...customer Freq Offset cal The range of frequency offset calibration is 0x0 0x7F MAC Address setup DA16200 provides 4 slots to store MAC addresses and the 1st slot is written by FCI The customer can us...

Page 17: ...CC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of th...

Page 18: ...device meets the exemption from the routine evaluation limits in section 2 5 of RSS102 and users can obtain Canadian information on RF exposure and compliance Le dispositif r pond l exemption des limi...

Page 19: ...DA16200 AT GUI Tool User Manual Revision 1 0 DRAFT 03 Jul 2019 CFR0012 19 of 20 2020 Dialog Semiconductor Revision History Revision Date Description 1 0 03 Jul 2019 Preliminary DRAFT Release...

Page 20: ...imitation the specification and the design of the related semiconductor products software and applications in accordance with its standard automotive change notification process Applications software...