UM-GP-002
GreenPAK Advanced Development Platform
User Manual
Revision 2.2
21-Feb-2020
CFR0012
23 of 40
© 2020 Dialog Semiconductor
Figure 22: Waveform, no Triggered on Button Released
Channel 1 (yellow/top)
– Logic generator
Channel 2 (light blue/2nd line)
– Button, 1 - enable Counter; 0 - disable Counter
Channel 3 (magenta/3rd line)
– Counter output
Figure 23: Waveform of the Pulse Width of the Logic Generator and Count End Signal
As shown in
and
Counter works only when the button is pressed.