3. Run a free running capture for a few seconds and note down the number in
the “
Avg Current
(mA)
” box (
). Note that the last digits of the number keep changing slowly due to
temperature drift. It is important to periodically execute the calibration steps.
Figure 48: Measuring Offset
4. Finally, put this average value with a negative sign in
the “
Calibration Offset (mA)
” box. CTRL-C
and CTRL-V also works.
Figure 49: Setting Calibration Offset
5. Re-insert the daughterboard or restore the jumper removed from J4 in the previous step.
NOTE
Please notice that the value in the
Voltage
box is 3 V. This is a typical value used across the industry for
comparing BLE power measurements. Therefore, the power configuration on DA14531 PRO-MB must be