background image

display. Press the 

ENTER

 button, the fixture working hours will show on the display. Press the 

MENU

 button to exit.

Lamp On time

To select 

Lamp On time

, press the 

ENTER

 button to show the 

LAMP ON TIME

 on the display.

Press the 

ENTER

 button to confirm, then use the 

UP/DOWN

 button to select 

Exit

 or 

Reset Time

press the 

ENTER

 button to store. Press the 

MENU

 button back to the last menu or exit menu mode

let the unit idle one minute. 

Firmware Version

To select 

Firmware Version

, press the 

ENTER

 button to show the 

FIRMWARE VERSION

 on 

the display. Press the 

ENTER

 button and the fixture software version will show on the display. 

Press the 

MENU

 button to exit.

Reset Functions

Enter MENU mode, select 

Reset Function

, press the ENTER button to confirm, use the 

UP/DOWN 

button to select

 Pan/Tilt, Zoom 

or

 All.

Pan/Tilt

To Select 

Pan/Tilt

, press the 

ENTER

 button to show the 

PAN/TILT

 on the display. Use the 

UP/DOWN

 button to select 

Yes

 (the unit will run built-in program to reset pan and tilt to their 

home positions)

 

or

 No

, press the 

ENTER

 button to store. Press the 

MENU 

button to exit menu 

mode.

Zoom

To select 

Zoom

, press the 

ENTER

 button to show the 

ZOOM

 on the display. Use the 

UP/DOWN

 button to select 

Yes

 (the unit will run built-in program to reset

 

zoom to its home 

positions)

 

or

 No

, press the 

ENTER

 button to store. Press the 

MENU 

button to exit menu mode.

All

To select

 All,

 press the 

ENTER

 button to show the 

ALL

 on the display. Use the 

UP/DOWN

 

button to select 

Yes

 (the unit will run built-in program to reset all motors to their home positions)

 

or

 No

, press 

ENTER

 button to store. Press 

MENU

 button to exit menu mode.

Special Functions

11D

Summary of Contents for IW19-10 ZOOM

Page 1: ...DIALighting IW19 10 ZOOM User Manual Please read the instruction carefully before use 0D...

Page 2: ...4 3 DMX 512 Configuration 15 5 Troubleshooting 16 6 Fixture Cleaning 16 1 Safety Instructions WARNING Please keep this User Manual for future consultation If you sell the unit to another user be sure...

Page 3: ...as it is fire hazard Use safety cables when fixing this unit DO NOT handle the unit by its head only always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where th...

Page 4: ...fixed to avoid vibration and slipping while operating and make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight...

Page 5: ...395mm 3 How To Set The Unit 3 1 Control Panel 1 Display Shows the various menus and the selected functions LED 2 POWER ON Power On 3 DMX ON DMX input present 4 Button MENU To select the programming fu...

Page 6: ...ture 11 Fuse T 6 3A Protects the unit from over voltage or short circuit 3 2 Main Function To select any of the given functions press the MENU button until the required function is showing on the disp...

Page 7: ...6D...

Page 8: ...N button to select Pan Inverse Tile Inverse P T Feedback BL O P T Moving White Balance Cooling Mode Dimmer Curve or Dimmer Speed Pan Inverse To select Pan Inverse press the ENTER button to show the PA...

Page 9: ...tton to confirm and use the UP DOWN button to adjust the value from 125 to 255 press the ENTER button to setup Press the MENU button back to the last menu or let the unit idle one minute to exit menu...

Page 10: ...lay Warning Display Inverse To select Display Inverse press the ENTER button to show the DISPLAY INVERSE on the display Use the UP DOWN button to select No normal or Yes display inverse Once selected...

Page 11: ...to Test press the ENTER button to show the AUTO TEST on the display Press the ENTER button the unit will run built in programs to automatically test pan tilt and zoom Press the MENU button back to the...

Page 12: ...the ENTER button to confirm use the UP DOWN button to select Pan Tilt Zoom or All Pan Tilt To Select Pan Tilt press the ENTER button to show the PAN TILT on the display Use the UP DOWN button to sele...

Page 13: ...use the UP DOWN button to select Exit or Reset time press the MENU button to exit Factory Setting To select Factory Setting press the ENTER button to show the FACTORY SETTING on the display Press the...

Page 14: ...tween pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of...

Page 15: ...DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press the ENTER button...

Page 16: ...4 3 DMX 512 Configuration 14 channels mode 15D...

Page 17: ...the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage o...

Page 18: ...Clean the external optics at least every 30 days 17D...

Page 19: ...18D...

Page 20: ...19D...