background image

8.DMX

8.DMX

8.DMX

8.DMX Channels

Channels

Channels

Channels

Mode/Channel

Mode/Channel

Mode/Channel

Mode/Channel

Function

Function

Function

Function

Values

Values

Values

Values

Description

Description

Description

Description

16B

8B

DE

1

1

11

Pan

0-255

PAN Movement

2

Pan Fine

0-255

Fine control of Pan movement

3

2

12

Tilt

0-255

Tilt Movement

4

Tilt Fine

0-255

Fine control of Tilt movement

5

3

3

Color

0-015

Open/White

016-031

Color 1

032-047

Color 2

048-063

Color 3

064-079

Color 4

080-095

Color 5

096-111

Color 6

112-127

Color 7

128-189

Forwards rainbow effect from fast to slow

190-193

Color rotation stop

194-255

Backwards rainbow effect from slow to fast

6

4

4

Gobo 1

0-009

Open

010-019

Gobo 1

020-029

Gobo 2

030-039

Gobo 3

040-049

Gobo 4

050-059

Gobo 5

060-069

Gobo 6

070-079

Gobo 7

080-099

Gobo 1 shake slow to fast

100-119

Gobo 2 shake slow to fast

120-139

Gobo 3 shake slow to fast

140-159

Gobo 4 shake slow to fast

periodic safety inspection of all installation material and the fixture. If you lack these qualifications,

do not attempt the installation yourself. Improper installation can result in bodily injury.

Be sure to complete all rigging and installation procedures before connecting the main power cord

to the appropriate wall outlet.

Clamp

Clamp

Clamp

Clamp Mounting:

Mounting:

Mounting:

Mounting:

The IS200-MH provides a unique mounting bracket assembly that integrates

the bottom of the base, the included “Omega Bracket,” and the safety cable rigging point in one

unit (see the illustration below). When mounting this fixture to truss be sure to secure an

appropriately rated clamp to the included omega bracket using a M10 screw fitted through the

center hole of the “omega bracket”. As an added safety measure be sure to attached at least one

properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the

base assembly

Regardless of the rigging option you choose for your IS200-MH, always be sure to secure your

fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the

hanging bracket as illustrated above. Be sure to only use the designated rigging point for the

safety cable and never secure a safety cable to a carrying handle.

5.

5.

5.

5. DMX-512

DMX-512

DMX-512

DMX-512 control

control

control

control connections

connections

connections

connections

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other

side to the male 3-pin XLR input of the moving head. You can chain multiple

Moving head together through serial linking. The cable needed should be two core, screened

cable with XLR input and output connectors. Please refer to the diagram below.

DMX-512 connection with DMX terminator

Reviews: