background image

Product Profile 

DSP-40S Vehicle Detector 

Fail Safe vs Fail Secure 

A  fail  safe  detector  will  output  “detect”  when  the  loop  circuit  is  failed.    This  is  always  useful  on  a 
safety  loop.  On  the  free  exit  loop  this  will  keep  the  gate  open  until  the  situation  is  fixed.    This  is 
useful in applications where it is important to allow traffic flow to continue. A fail secure detector will 
never output “detect” when the loop circuit is failed.  This will keep the gate closed.  This is useful in 
high-security  areas  or  installations  where  containment  is  needed.    The  DSP-40S  is  a  fail  safe 
detector.  

Note:

 Never use a fail secure detector on a safety loop.   

Outputs 

Solid-state (open transistor collectors) for both detect and fail outputs. 30 mA maximum current sink 
- transient voltage protected.

Power 

12 to 30 volts DC 

Operating Temperature 

-35°F to 165°F (-37°C to 74°C)

Size 

Height: 2.4" 

 Width: 0.8" 

 Depth: 2.25” 

Connector 

10-position Molex Type 09-48-1104
Mates with many female PCB 0.156” pitch headers in use by some access control devices and gate
operators.

1 - Loop input  
2 - Loop input 
3 - Power* (10 to 30 volts AC or DC)  
4 - No Connection 
5 - No Connection 
6 - Fail output -connects to common for fail. 
7 - Fail output -connects to common for fail. 
8 - Detect output -connects to common for detect. 
9 - Power* (10 to 30 volts AC or DC) 
10 - Power Common 

*Either or both of these pins can be used to supply power to the detector.

Ordering Information 

Only one model available: DSP-40S 

gateopenersafety.com

Reviews: