Product Profile
DSP-40S Vehicle Detector
Fail Safe vs Fail Secure
A fail safe detector will output “detect” when the loop circuit is failed. This is always useful on a
safety loop. On the free exit loop this will keep the gate open until the situation is fixed. This is
useful in applications where it is important to allow traffic flow to continue. A fail secure detector will
never output “detect” when the loop circuit is failed. This will keep the gate closed. This is useful in
high-security areas or installations where containment is needed. The DSP-40S is a fail safe
detector.
Note:
Never use a fail secure detector on a safety loop.
Outputs
Solid-state (open transistor collectors) for both detect and fail outputs. 30 mA maximum current sink
- transient voltage protected.
Power
12 to 30 volts DC
Operating Temperature
-35°F to 165°F (-37°C to 74°C)
Size
Height: 2.4"
Width: 0.8"
Depth: 2.25”
Connector
10-position Molex Type 09-48-1104
Mates with many female PCB 0.156” pitch headers in use by some access control devices and gate
operators.
1 - Loop input
2 - Loop input
3 - Power* (10 to 30 volts AC or DC)
4 - No Connection
5 - No Connection
6 - Fail output -connects to common for fail.
7 - Fail output -connects to common for fail.
8 - Detect output -connects to common for detect.
9 - Power* (10 to 30 volts AC or DC)
10 - Power Common
*Either or both of these pins can be used to supply power to the detector.
Ordering Information
Only one model available: DSP-40S