Electrical Data
DSP-13M Operating Voltage: 8 volts to 30 volts DC
DSP-13M Operating Current:
60 milliamps maximum and includes all current used by the sensors.
DSP-13M Output Rating:
The output is an open-collector output rated for sinking up to 50 milliamps. It is
not an isolated output and is referenced to pin 10 (Common) of the DSP-13M.
Sensor to Sensor Proximity:
The sensors are passive measurement devices and as such will not interfere
with other sensors at any distance.
Environmental Data
Operating Temperature:
-35°F to 165°F (-37°C to 74°C)
Storage Temperature:
-40°F to 176°F (-40°C to 80°C)
Humidity:
Up to 95% relative humidity non-condensing
Mechanical Data
DSP-13M Mounting Position:
Any
DSP-13M Housing Material:
ABS
DSP-13M Size:
2.375 inches (High) x 2.340 inches (Wide) x .860 inches (Deep)