9) Specifications

24 Month Warranty

Di-Log instruments are subject to stringent quality controls.
If in the course of normal daily use a fault occurs we will
provide a 24 month warranty (only valid with invoice). Faults
in manufacture and materials defect will be rectified by us
free of charge, provided the instrument has not been
tampered with and returned to us unopened. Damage due
to  dropping, abuse or misuse is not covered by the warranty.

Outside the warranty period we offer a full repair and
re-calibration service.

Di-Log Test Equipment
28 Wheel Forge Way
Trafford Park
Manchester M17 1EH
UK
Tel: +44 161 877 0322
Fax +44 161 877 1614
Website: www.dilog.co.uk
Email: [email protected]

DL6780V1

Voltage

DL6780

DL6790

Voltage display

12 – 690 V AC/DC

6 – 690 V AC/DC

LED Resolution

12, 24, 50, 120, 230,

12, 24, 50, 120, 230,

400, 690

400, 690

LCD Resolution

1 V +/- 3 % + 8 digits

Voltage detection

automatic

automatic

Acoustic signal

AC voltage – DC

AC voltage – DC voltage

voltage

Polarity detection 

Full range

Full range

Response time

LED < 0.1s

LED <0. 1s, LCD <2s

Frequency range

0 – 400 Hz

0 – 400 Hz

Peak Current

Is<0.3A/Is(after 5s)

Is<0.3A/Is(after 5s) <3.5 mA

<3.5 mA

Operation time

30s

30s

Recovery time

10 min

10 min

Auto power on

<12 V AC/DC

<12 V AC/DC

Single pole
voltage indication
Voltage range

100 – 690 V AC

100 – 690 V AC

Frequency range

50 – 400 Hz

50 – 400 Hz

Continuity
Measuring range

0 - 400 Kohm

0 - 400 Kohm

Phase rotation test
Voltage range

100 – 690 V

100 – 690 V

Frequency

45 – 65 Hz

45 – 65 Hz

Over voltage

690 V AC/DC

690 V AC/DC

protection
Power supply

2 x 1.5 LR03 battery

2 x 1.5 LR03 battery

Dimensions

255 x 70 x 28 mm

255 x 70 x 28 mm

Weight

200g

200g

DiLog Instructions Inner8pp  6/3/07  11:22  Page 

Summary of Contents for DL6780 Combi Volt 1

Page 1: ...Di LOG Instruction Manual DL6780 Combi Volt 1 DL6790 Combi Volt 2 ...

Page 2: ...ly automatic voltage indicators capable of measuring AC DC voltage up to 690 V Both units have visual and acoustic continuity indication Constructed in accordance with IEC 61010 and IEC 61243 3 Single pole phase indication 2 pole phase rotation indication LED LCD display DL6790 2 Safety notices This manual contains information that must be followed for operating the meter safely and maintaining th...

Page 3: ...e connectors If the case is damaged do not use the meter Check the test probes for damaged insulation or exposed metal Check the leads for continuity Do not apply more than the rated voltage as marked on the meter between the terminals or between any terminal and ground Do not use or store the meter in an environment of high temperature humidity fumes vapour gaseous inflammable and strong magnetic...

Page 4: ... pole test of phase rotation and single pole test 9 Torch button on the back 10 Positive LED 11 Negative LED 12 Battery Compartment Carrying out measurements Perform a self test of the unit Connect the two test probes L1 and L2 The continuity LED 6 will be lit and an audible tone should be heard Before any test check the unit on a known voltage source If the unit is defective it should be put out ...

Page 5: ...bes to voltage source observing polarity of the test probes L2 is positive probe L1 is the negative probe For AC voltage the value is indicated on the LEDs 3 and on the LCD display DL6790 only The and LEDs are illuminated and buzzer is audible For DC voltage connect probe L2 to the positive terminal and L1 to the negative terminal The voltage is displayed on the LEDs and the LCD display DL6790 onl...

Page 6: ...keep finger on the contact electrode 8 If an AC voltage above 100 V is present the LED 4 is illuminated and the buzzer sounds The single pole test can be negatively affected by unfavourable conditions such as electrostatic field good insulation etc 6 Continuity test The continuity test is only possible when batteries are inserted and in good condition Ensure the circuit under test is not live Conn...

Page 7: ...ior to this test This unit can determine the phase rotation within a three phase supply Connect test probe L2 to the supposed phase 2 and the test probe L1 to the supposed phase 1 If the R LED illuminates the phases are in the correct sequence 1 to 2 ...

Page 8: ...items in this unit Never attempt to open the casing apart from the battery cover Do not use the instrument if there is any physical damage to the case or test leads The outside of the unit can be cleaned with a soft damp cloth only Do not use abrasive or chemical cleaning agents Changing batteries Turn the battery cover by 90 degrees anti clockwise Remove the cover and take out spent batteries Rep...

Page 9: ...90 Voltage display 12 690 V AC DC 6 690 V AC DC LED Resolution 12 24 50 120 230 12 24 50 120 230 400 690 400 690 LCD Resolution 1 V 3 8 digits Voltage detection automatic automatic Acoustic signal AC voltage DC AC voltage DC voltage voltage Polarity detection Full range Full range Response time LED 0 1s LED 0 1s LCD 2s Frequency range 0 400 Hz 0 400 Hz Peak Current Is 0 3A Is after 5s Is 0 3A Is a...

Page 10: ......

Reviews: