background image

Please read this manual before switching the unit on.

Important safety information inside.

DL6519

TRMS AC Leakage 

Current Clamp Meter

Summary of Contents for DL6519

Page 1: ...Please read this manual before switching the unit on Important safety information inside DL6519 TRMS AC Leakage Current Clamp Meter ...

Page 2: ...True RMS AC Clamp Leakage Current Tester User s Manual ...

Page 3: ...e 50 60 and Wide Selector B AC Load Current Measurement C AC DCVoltage Measurements D Resistance and continuity Measurement E PEAK Value Measurements F Holding the LCD Reading Backlit on off G Finding the MAX MIN Value H Auto Power Off 4 Specifications 5 Battery Replacement 4 5 8 8 8 9 10 10 11 12 13 13 13 13 13 15 True RMS AC Clamp Leakage Current Tester User s Manual 6 Warranty Information 16 ...

Page 4: ...s designed to eliminate the effect of high frequency noise and harmonics by setting the frequency selector switch at the 50 60 Hz position for AC current measurement Large 3 1 2 digits LCD Fast bargraph display 20 times sec for transient observation Continuity measurements Max Min and Data Hold functions Peak Value Measurement 600V overload protection for DC ACV ohm range measurement Easy single r...

Page 5: ...r desired such as AC DCV ACA ohm and continuity This button is used to enable the maximum or minimum value to be displayed and updated during measurement Press once minimum value shall be displayed and updated press again maximum value shall be displayed and updated Press hold the button again the third push clamp meter return to normal measurement mode This button is used to enable the Peak value...

Page 6: ...raph sign decimal points low battery symbols Peak Max Min symbols symbol are included This terminal is used as input for voltage or ohm continuity measurements This terminal is used as common reference input True RMS AC Clamp Leakage Current Tester User s Manual LCD Description 11 Low Battery Symbol When this symbol appears it means the battery voltage drops below the minimum required voltage Refe...

Page 7: ...e the Max Min button is pressed either MAX or MIN shall be displayed on LCD If ohm and continuity function is selected this symbol shall appears on LC Once a function is selected corresponding unit V 12 Data Hold Symbol 13 Bargraph 14 Max Min Hold symbol 15 Continuity Symbol 16 Units symbols Ω A or Hz shall be displayed on LCD True RMS AC Clamp Leakage Current Tester User s Manual ...

Page 8: ... LE MIN CO M V CAT III 600V V mA TRU E RM S AC CLA MP LEA KAG E CUR REN T TES TER AUT O POW ER OFF WARNING 1 Leakage current Flowing into Ground conductor Make sure that all the test leads are disconnected from the meter s terminals for current measurement Ω Ω 2A 20A 200 A 100 0A 200 OFF MO DE MA X PEA K HO LE MIN CO M V CAT III 600V V mA TRU E RM S AC CLA MP LEA KAG E CUR REN T TES TER AUT O POW ...

Page 9: ...the LCD display t 2 Out of Balance Leakage curren Ω Ω 2A 20A 200 A 100 0A 200 OFF MO DE MAX PEA K HOL E MIN CO M V CAT III 600V V mA TRU E RMS AC CLA MP LEA KAG E CUR REN T TES TER AUT O POW ER OFF Ω Ω 2A 20A 200 A 100 0A 200 OFF MO DE MAX PEA K HOL E MIN CO M V CAT III 600V V mA TRU E RMS AC CLA MP LEA KAG E CUR REN T TES TER AUT O POW ER OFF True RMS AC Clamp Leakage Current Tester User s Manual...

Page 10: ...requency is set at 100Hz with an attenuation characteristic of approx 24dB octave Wide Hz Selector If the circuit under test is originated from a high frequency generating device such as inverter switching regulators etc then the switch should be set at wide position to measure the signal which contains the frequency from 40Hz 1kHz To make sure the presence of high frequency signal set the switch ...

Page 11: ...0A 1000A 200 OFF MODE MAX PEAK HOLE MIN COM V CAT III 600V V mA TRUE RMS AC CLAMP LEAKAGE CURRENT TESTER AUTO POWER OFF MAX PEAK Ω C F MIN H INRUSH WIDE 50 60Hz AC DC AT Hz mA V k P WARNING Maximum input for DC V is 600 and for AC V is 600 Do not attempt to take any voltage measurement that exceeds the limits Exceeding the limits could cause electrical shock and damage to the clamp meter True RMS ...

Page 12: ...cuit being tested and discharge all the capacitors Set the rotary switch at Ω Insert the test leads into the input jack Connect the test prods of the test leads to the two ends of the resistor or circuit be measured Read the measured value from the LCD display If the resistance is lower than 40Ω a beeping sound shall be heard True RMS AC Clamp Leakage Current Tester User s Manual Ω Ω 2A 20A 200A 1...

Page 13: ...alue shall be displayed and updated Push again second push the minimum value shall be displayed Push again third push MAX MIN function shall be disabled and return to the normal measurement mode The meter will turn itself off 30 minutes after power on To turn it on again 4 Specifications Accuracy Range 600V Resolution 0 1V 50 60Hz 1 5 2dgts 40 1KHz 2 0 4dgts Overload protection AC DC 600V AC DC Vo...

Page 14: ...ling Time Operating Temperature Operating Humidity Storage Temperature Storage Humidity Accessories 68mm max approx One 9V NEDA 1604 MAX 6000 counts LCD with 32seg Bargraph manual left most digit blinks 10mA approx 2 times sec display 20 times sec bargraph 10 to 50 less than 85 relative 20 to 60 C C C C less than 75 relative Test leads 1 Gift box with carrying case 9V NEDA 1604 1 Users manual 1 1 ...

Page 15: ...ies Turn the power off and remove the test leads from the clamp meter Remove the screw of the battery compartment Slide off the battery compartment Remove the old batteries Insert one 9V NEDA 1604 or G6F22 batteries Replace the battery compartment and secure the screw True RMS AC Clamp Leakage Current Tester User s Manual ...

Page 16: ...ied by us free of charge provided the instrument has not been tampered with and returned to us unopened Damage due to dropping abuse or misuse are not covered by the warranty The supplied test leads are deemed a wear and tear item and are not covered by the warranty however replacement leads are available to purchase as an accessory Di LOG Ltd Unit 28 Wheel Forge Way Trafford Park Manchester M17 1...

Reviews: