DHR DHR420RCB Technical Manual Download Page 6

6

Version 1.3 Nov. 2017

Den Haan Rotterdam

1. MOUNTING INSTRUCTIONS

Mounting the panel

Place the control panel inside the wheelhouse, where it is protected against weather influences. The housing 

is especially constructed to be flush mounted in an instrument cabinet according the illustration below.

The minimum space needed behind the panel is 60 mm. (depth)

Searchlight installation

Install the searchlight in a horizontal upright position with sufficient space around the head of the search-

light to ensure it can move freely. The dimensions can be found on page 9.

Warning!

Den Haan Rotterdam accepts no responsibility for any damage if the searchlight is installed 

incorrectly and/or used improperly. When in doubt consult a qualified electrical technician.

90

90

92

92

75

75

!

Bolt M10x (60 + M)
Insulation sleeve
Lantern base

Insulation sleeve

Washer M10 

Mounting plate Min. 5 mm

Nut M10 

M

All dimensions in mm 

Fasteners

•  The permissible torque should be 8 Nm

•  Use only A4-grade stainless steel 

Caution!

Even though the housing is made of corrosion resistant materials, galvanic corrosion may still occur. To 

prevent galvanic corrosion use the supplied insulation sleeves to isolate the aluminium housing from 

other metal parts.

4 x Ø10

162,5

162,5

Summary of Contents for DHR420RCB

Page 1: ...Den Haan Rotterdam TECHNICAL MANUAL SINCE 1922 420RCB Searchlight and Control System...

Page 2: ...2 Version 1 3 Nov 2017 Den Haan Rotterdam Intentionally blank page...

Page 3: ...ot exceed 105 of rated voltage Allow lamp fixture to cool before handling Do not use the searchlight if outer glass is scratched or broken Damage due to inappropriate handling is not covered by the wa...

Page 4: ...ion for tugs workboats cargo vessels or even larger inland vessels this type of searchlight is easy in use and made for the job Installation is straight for ward due its well thought mechanical and el...

Page 5: ...s 6 2 Maintenance 8 3 Specifications 9 4 Dimensions Searchlight 11 5 Photos Searchlight 13 6 Dimensions control panel 15 7 Wiring diagram searchlight 16 8 Wiring diagram control panel 17 9 Wiring diag...

Page 6: ...freely The dimensions can be found on page 9 Warning Den Haan Rotterdam accepts no responsibility for any damage if the searchlight is installed incorrectly and or used improperly When in doubt consul...

Page 7: ...his gives unwanted stress at the sealing of the cable gland and water ingress will occur Include cable slack at the entering point of the cable gland Replacing cable gland Use gasket between housing a...

Page 8: ...lamp is of the same type 6 Take a clean cloth to place the new lamp in the lampholder Do not touch the lamp with bare fingers remove any fingerprints with a cloth and alcohol and rub it dry 7 Close t...

Page 9: ...00 000 cd Bulb Model Osram 64788 CP 72 Luminous flux 52 000 lm Rated lamp voltage 230 240 V Rated lamp wattage 2000 Watt Average life time 400 h Color temperature 3200 K Base GY16 Heater Type PTC heat...

Page 10: ...erdam Control panel Model PAN2016 Dimensions Depth 110 mm Width 110 mm Weight 0 25 kg Electrical Voltage 24 VDC Maximum wattage 5 W Fuse 2x T5A Electrical insulation class III Housing Front Aluminium...

Page 11: ...11 Version 1 3 Nov 2017 Den Haan Rotterdam 500 876 530 4 DIMENSIONS SEARCHLIGHT All dimensions are in mm...

Page 12: ...12 Version 1 3 Nov 2017 Den Haan Rotterdam 290 DHR420 with pedestal 256 140 8 x 12 5 1000...

Page 13: ...13 Version 1 3 Nov 2017 Den Haan Rotterdam 5 PHOTOS SEARCHLIGHT...

Page 14: ...14 Version 1 3 Nov 2017 Den Haan Rotterdam...

Page 15: ...am 6 DIMENSIONS CONTROL PANEL Controls 1 FOCUS controls with Joystick position lamp 2 SPEED 50 or 100 3 BEAM ON OFF switches the lamp on or off 4 JOYSTICK controls the direction of the movement All di...

Page 16: ...0 5 mm Motorhouse 24VDC Speed Speed Left Right Up Down Focus Lamp Focus Focus Relayout Relayout 24VDC L N NotUsed Ground 24VDC PTC 1 2 3 4 5 6 7 8 Focus Focus Lamp Lamp 24VDC PTC Ground Relay in Rela...

Page 17: ...24VDC 18 23VDC F10A X1 X2 5 6 7 8 1 2 3 4 Speed Speed Left Right Up Down Focus Lamp L N NotU sed Ground 24VDC 24VDC X3 Motorhouse No Description A 24VDC out B 24VDC out 1 Speed 2 Speed 3 Left 4 Right...

Page 18: ...X1 X3 1 X1 X2 Not Used X3 Speed Speed Left Right Up Down Focus Lamp Ground L N NotUsed 24VDC 24VDC Motorhouse 7 8 5 6 2 1 3 4 A B No Description A 24VDC out B 24VDC out 1 Speed 2 Speed 3 Left 4 Right...

Page 19: ...WIRING DIAGRAM SWITCHES DIGITAL LN PE F10A 230VAC OR OR 24VDC Imax 5A Motorhouse L N Not Used 24VDC 24VDC Speed Speed Left Right Up Down Focus Lamp 7 8 5 6 2 1 3 4 I 5 130mA 8x Ground PTC Heater 70 W...

Page 20: ...SPARE PARTS Spare Part No Description Order code 1 Halogen Bulb GY16 230V 2000W CP72 2 Lampholder GY16 42001 3 Maxon motor A max 22 UC07 4 Glass mirror 420 mm 42005 5 Front glass 42003 6 Motor frame...

Page 21: ...21 Version 1 3 Nov 2017 Den Haan Rotterdam 4 5 6 7...

Page 22: ...SINCE 1922 ADVANCED MARITIME SIGNALLING SOLUTIONS Den Haan Rotterdam Fascinatio Boulevard 1182 2909 VA Capelle a d IJssel The Netherlands T 31 0 10 413 07 55 E sales dhr nl www dhr nl...

Reviews: