What to Do If…
41
Chapter 4 Read This Chapter Whenever You Face a Problem. (FAQ)
Cutting Data Can Not Be Output to the Machine, or the Machine Does Not Operate Although Cutting Data Is Output to It
Is the front cover or maintenance cover open?
If the front cover or maintenance cover is open, the machine does not start cutting even if it receives cutting data. Close all
covers, and press the button of the machine. Cutting will begin.
Does VPanel recognize the machine?
Make sure that a message other than "Offline (Off displayed)" is displayed on the screen of VPanel.
When plural machines are connected, is the selected machine correct?
Select a machine to which you want to output cutting data on the screen of VPanel.
Is operation paused?
When the PAUSE LED is on, it means that operation is paused. When the machine is paused, cutting stops and some opera-
tions are restricted. When you press the operation button of the machine shortly, the pause is canceled. When you hold down
the operation button, cutting is stopped.
Is initialization or data cancel in progress?
The cutting data received in the middle of initialization or data cancel will be cancelled. Output cutting data after confirming
that the machine is in the standby status.
Is the cutting data correct?
Check the cutting data.
Does any error exist?
The error LED will flicker if an error occurs. Details of the error will be displayed on the screen of VPanel.
P. 51, "Responding to an Error Message"
The Computer Shut Down When Plural Machines Were Connected
Is a machine with a same ID connected to the computer?
When more than one machine is connected to the computer, if machines with a same ID are connected at the same time,
the computer might shut down. If the computer shuts down, turn off the power of all the connected machines and discon-
nect the USB cables from the computer.
Next, restart the computer, and then start VPanel. If VPanel does not start, install it again. Then, make the setting again in a
way that a same ID is not assigned to more than one machine.
"Setup Guide" ("Connecting Multiple Units")
The Ionizer Is Not Effective (Cutting Waste Adhere to the Around Wall of Cutting Area)
Is the workpiece being cut PMMA?
The ionizer (static eliminator) is effective for only PMMA and is not effective for zirconia or wax.