True-Flat Healthcare Display
with color calibration
User’s Manual
MDPi Series
ver.A_MP_3-1521_13-13
Page 1: ...True Flat Healthcare Display with color calibration User s Manual MDPi Series ver A_MP_3 1521_13 13...
Page 2: ...fication purpose only and are the properties of the respective owners Notice 1 The changes or modifications not expressly approved by the party responsible for compli ance could void the user s author...
Page 3: ...r 4 Monitor Installation 15 4 1 Cleaning instructions 15 4 2 Stand removal VESA mount installation 16 Chapter 5 Daily operation 18 5 1 Main power switch 18 5 2 Power Status indication 18 Chapter 6 OSD...
Page 4: ...ortable on a table Intended location Medical environment Intended User Profile Intended User Profile X 1 2 Box of contents 21 5 23 8 27 LCD Touch Screen Monitor AC Power Cord VGA Cable DVI or HDMI Cab...
Page 5: ...ION Chapter 1 INTRODUCTION Side View The image below shows the control keys located in the right bottom corner of the display 1 Menu Enter key Scrolling key Rear View 1 Rear cover 2 IO cover 3 Monitor...
Page 6: ...User s Manual MDPi Series 6 Chapter 1 INTRODUCTION Available Connections 1 USB 2 RS232 3 Audio 4 Display Port 5 DVI 6 HDMI RGD model 7 VGA 8 POWER 9 User s Manual MDPi Series...
Page 7: ...AC Input External power adapter 100 250V External power adapter 100 250V External power adapter 100 250V Power Consumption 40W Max 40W Max 40W Max Mechanical Chassis Material Plastic ABS Plastic ABS P...
Page 8: ...8 Chapter 1 INTRODUCTION User s Manual MDPi Series X 1 5 Outline Dimension...
Page 9: ...s and receptacles The power supply cord should be replaced by the designated operator only at all time Use a power cord that matches the voltage of the power outlet which should be approved and in com...
Page 10: ...indicates that under the European Directive 2012 19 EU governing waste from electrical and electronic equipment this product must not be disposed of with other municipal waste Please dispose of your...
Page 11: ...determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the...
Page 12: ...WEEE Waste Electrical and Electronic Equipment directive Indicates Direct Current DC Indicates Alternating Current AC Stand by Power ON Power connection to the mains Power OFF Protective earth ground...
Page 13: ...it is used in such an environment Emissions test Compliance Electromagnetic environment Guidance RF emissions CISPR 11 Group 1 The monitor uses RF energy only for its internal function Therefore its R...
Page 14: ...tery Power fre quency 50 60 Hz mag netic field IEC 61000 4 8 30 A m Not applicable Power frequency mag netic fields should be at levels characteristic of a typical location in a typical commercial or...
Page 15: ...n function 3 Connect the Audio cable for audio function 4 Connect the power cord input to a power adapter with a grounded Power Outlet 5 Connect the power adapter input to the monitor 6 Install cable...
Page 16: ...t 1 Place the monitor face down on a flat solid and stable surface 2 Remove the hinge cover 3 Unscrew the 4x M4 length 10mm screws fixing the stand and rear cover 4 Remove the stand and install the VE...
Page 17: ...nstallation User s Manual MDPi Series 5 Attach the monitor in landscape position to a 100 mm VESA mounting bracket Mounting in portrait position is not feasible Image 4 2 4 VESA mount is located at th...
Page 18: ...detection before going into normal operation mode Depending on the detection result the status LED on the side of the monitor will show different LED color Below is an overview of the possible status...
Page 19: ...th a status bar will appear The status bar indicates in which direction form the fac tory preset your adjustments arebeing made Rotate the Control Dial to adjust the control When you have finished mak...
Page 20: ...DPi Series X 6 4 Main Menu 6 4 1 Exit 6 4 2 Auto Setup Only Support Analog Exit To exit the auto setup of the OSD menu Yes Automatically adjust the analog settings of the image No Enter Clock Phase OS...
Page 21: ...t Analog H Position The function allows user manually adjust the image position horizontally on the screen This function allows the user to adjust the monitor s brightness setting manually This functi...
Page 22: ...er can adjust and set tones Red Adjust red and equivalent colors at the range from 0 to 100 The greater the value is the deeper the color is and vice versa Yes Automatically adjust the analog settings...
Page 23: ...reset gamma curve of the display setting Preset gam ma curve are Neutral Gamma 2 2 DICOM Allows users to select preset DICOM curve of the display setting 6 4 7 Clock Phase Only support Analog 6 4 8 Au...
Page 24: ...o output of the display setting Input Allows users to select the audio input source of the display setting Digital Line In audio input source are available Mute Allows users to Mute On Unmute Off the...
Page 25: ...lows users to select preferred image scaling of the display setting Full screen Expands the current image to the full size of the monitor Aspect ratio 5 4 4 3 16 9 Expands the video image until its la...
Page 26: ...nction of the display set ting 6 4 9 3 Scaling 6 4 9 4 Source VGA DVI Display Port DP HDMI sources are available for user to select preferred input source Exit To exit the Language of the OSD menu Eng...
Page 27: ...of the OSD menu Locked Allows users to Enable the DC power key function of the display setting Unlocked Allows users to Disable the DC power key function of the display setting Exit To exit the Recal...
Page 28: ...28 Chapter 6 OSD menu operation User s Manual MDPi Series 6 5 Supported Video Modes Compliant Graphic Signal Timing VGA DVI HDMI DP...