BIOS Setup
PWRON After PWR-Fail
Off
When power returns after an AC power failure, the
system’s power is off. You must press the Power
button to power-on the system.
On
When power returns after an AC power failure, the
system will automatically power-on.
Former-Sts
When power returns after an AC power failure, the
system will return to the state where you left off
before power failure occurs. If the system’s power is
off when AC power failure occurs, it will remain off
when power returns. If the system’s power is on
when AC power failure occurs, the system will power-
on when power returns.
Serial Port 1, Serial Port 2, Serial Port 3 and Serial Port 4
Auto
The system will automatically select an I/O address for
the onboard serial port 1, 2, 3 or 4.
3F8/IRQ4, 2F8/IRQ3, 3E8/IRQ4, 2E8/IRQ3
Allows you to manu-
ally select an I/O address for the onboard serial port 1,
2, 3 or 4.
Disabled
Disables the onboard serial port 1, 2, 3 or 4..
Serial Port 3 Use IRQ and Serial Port 4 Use IRQ
These fields are used to select an IRQ for the onboard serial port 3
and serial port 4.