5.4 TENSION DATA AND STATUS
After the module is added input Tags carry the calibrated tension value if the unit is calibrated and other status
information of the device. If calibration of the unit is required see the section
. All tag data is Signed
32–bit integer value. The input tags descriptions are as follows:
Input Tags:
STATUS_BITS
Status
Name
Definition
0
Amplifier locked No Button access is allowed for zero or
calibration
1
Calibrated at unit Indicates that the last valid calibration was
performed using the buttons
2
Zeroed at unit
Indicates that the last zero operation was
performed using the buttons
3-6
RESRVED
Always Zero
7
Heartbeat Bit
Bit toggles every 0.5 seconds approx.
8-13
RESRVED
Always Zero
14
Command
Processed
Bit set High after a command is processed,
can be used in ladder logic to reset the
command register to zero (no command)
15
AMP OK
SUMMARY Bit indicating no error status.
16-31
RESRVED
Always Zero
AMP_STATUS
Status
Definition
0x00000000 Amplifier OK – Normal Operation
0x00000001 Internal Failure
0x00000002 No cailbration
0x00000003 Out of Range – Amplifier is calibrated but is experiencing an overload or underload
condition.
0x00000004 A wiring error is detected – in rare occurnences this error could be caused by an extreme
overload conditions on load cells.
0x00000005 An error is detected with the excitation of the load cells – usually this means a short circuit is
present externally to the amplifier.
31-16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RE
SE
RV
ED
STATUS_BITS
RE
SE
RV
ED
RE
SE
RV
ED
HE
AR
TB
EA
T
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
AM
P_
OK
CM
D P
RO
CE
SS
ED
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
Zer
or
ed
A
t U
ni
t
Ca
lib
ra
te
d A
t U
nit
Am
p L
oc
ked