DeZURIK
BHP High Performance Butterfly Valves
D10503
Page 22
November 2015
Seat Replacement
(Continued)
Metal Seat Option (S2)
a. If the actuator is connected to the
valve shaft, loosen the
connection so that the valve
shaft can rotate.
b. Loosen the packing gland nuts
(A15).
c. Place the seat support ring (A29)
in the body.
d. Center the gasket (A27) and the
metal seat (A28) on the closed
disc.
e. Apply a media compatible rust
inhibitor to the threads of the
seat retainer screws (A23).
f. With all components centered,
mount the seat retainer (A20) to
the body with the seat retainer
screws. Tighten the screws as shown in Table D (page 23).
g. If the valve-to-actuator connection was loosened in step a, re-tighten the connection.
h. Adjust the packing gland nuts (A15) as described in the
Packing Adjustment
section. If the
packing is live-loaded, tighten the nuts as shown in Table A (page 17) for Class 150 valves, or
in Table B (page 18) for Class 300 valves.
i. Continue with step 7 on page 24.
Figure 12 — Metal Seat Option (S2)