5.6 Ba�ery Setup Menu
Batt Mode
Lithium
Use Batt V
Battery Setting
Activate Battery1
Parallel bat1&bat2
Activate Battery2
Max A Charge
Batt Capacity
Max A Discharge
0A
0A
0Ah
Batt
Mode
Use Batt %
No Batt
Ba�ery capacity:
it shows your ba�ery bank size to
Deye hybrid inverter.
Use Ba� V:
Use Ba�ery Voltage for all the se�ngs (V).
Use Ba� %:
Use Ba�ery SOC for all the se�ngs (%).
Max. A charge/discharge:
Max ba�ery charge/discharge
current(0-50A for 29.9/30/35/40/50KW model).
For AGM and Flooded, we recommend Ah ba�ery
size x 20%= Charge/Discharge amps.
. For Lithium, we recommend Ah ba�ery size x 50% =
Charge/Discharge amps.
. For Gel, follow manufacturer' s instruc�ons.
No Ba�:
�ck this item if no ba�ery is connected
to the system.
Ac�vate Ba�ery1/Ac�vate Ba�ery2:
This feature will
help recover a ba�ery that is over discharged by slowly
charging from the solar array or grid.
Grid Charge
Gen Charge
Grid Signal
Gen Signal
Gen Force
Battery Setting
Start
A
30%
30%
50A
50A
Batt
Set2
①
②
③
This is Ba�ery Setup page.
Start =30%:
Percent SOC below 30% system will AutoStart
a connected generator to charge the ba�ery bank.
A = 50A:
Charge rate of 50A from the a�ached
generator in Amps.
Gen Charge:
uses the gen input of the system to charge
ba�ery bank from an a�ached generator.
Gen Signal:
Normally open relay that closes when the
Gen Start signal state is ac�ve.
Gen Force:
When the generator is connected, it is forced
to start the generator without mee�ng other condi�ons.
①③
Start =30%:
No use
,
Just for customiza�on.
A = 50A:
It indicates the Current that the
Grid charges the Ba�ery.
Grid Charge:
It indicates that the grid charges
the ba�ery.
Grid Signal:
Disable.
This is Grid Charge, you need select.
②