61
-
11.Specifica�on
Model
Input Side
Max.DC Power(kW)
Max.DC Input Voltage(V)
Start-up DC Input Voltage(V)
MPPT Opera�ng Range(V)
Max.DC Input Current(A)
250
800
200~700
Max. Short Circuit Current (A)
Number of MPPT/Strings per MPPT
40+40
SUN-20K-G02-LV
26
2/3
0
60+60
Output Side
Rated Output Power(kW)
Max.Ac�ve Power(kW)
Rated AC Grid Voltage(V)
AC Grid Voltage Range(V)
Rated Grid Frequency(Hz)
Opera�ng Phase
Rated AC Grid Output Current(A)
Max.AC Output Current(A)
3L/N/PE 127/220V
0.85Un-1.1Un (this may vary with grid standards)
60 / 50 (Op�onal)
Three phase
20
22
52.5
57.8
100.2
111.4
DC Injec�on Current(mA)
Grid Frequency Range
Max.Efficiency
Euro Efficiency
>99%
MPPT Efficiency
Efficiency
General Data
Output Power Factor
<0.5%
57-62
98.7%
98%
0.8 leading to 0.8 lagging
<2%
Grid Current THD
362×577×215
Transformerless
Size(mm, W×H×D)
25.5
Weight(kg)
Topology
<1W(Night)
Internal consump�on
Opera�ng temperature
Ingress protec�on
IP65
<50dB
Smart cooling
Max. opera�on al�tude
Cooling Concept
Noise Emission(Typical)
2000m
Grid Connec�on Standard
Opera�on surrounding humidity
0~100%
Safety EMC / Standard
MAX inverter backfeed current (A)
Maximum output fault
current (a.c. A, peak )
Maximum output overcurrent
protec�on (a.c. A,peak)
-25 ~ 65
℃
,>45
℃
dera�ng
CEI 0-21,VDE-AR-N 4105,NRS 097,IEC 62116,IEC 61727,G99,G98,VDE 0126-1-1,RD 1699,C10-11
IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4
>20 Years
Designed Life�me