- 63 -
11.Specifica�on
Model
Input Side
Max.DC Power(kW)
Max.DC Input Voltage(V)
Start-up DC Input Voltage(V)
MPPT Opera�ng Range(V)
Max.DC Input Current(A)
250
1000
200~850
SUN-70K
-G03
91
SUN-75K
-G03
97.5
SUN-80K
-G03
104
SUN-90K
-G03
135
SUN-100K
-G03
150
SUN-110K
-G03
150
Max. Short Circuit Current (A)
Number of MPPT/Strings per MPPT
Output Side
Rated Output Power(kW)
Max.Ac�ve Power(kW)
Rated AC Grid Voltage(V)
AC Grid Voltage Range(V)
Rated Grid Frequency(Hz)
Opera�ng Phase
Rated AC Grid Output Current(A)
Max.AC Output Current(A)
3L/N/PE 230/400V 220/380V
0.85Un-1.1Un (this may vary with grid standards)
50/60(Op�onal)
Three phase
70
77
106.1/101.5A
116.7/111.6A
75
82.5
113.6/108.7A
125/119.6A
80
88
121.2/115.9A
133.3/127.5A
90
99
136.4/130.4A
150/143.5A
100
110
151.5/144.9A
166.7/159.4A
110
121
166.7/159.4A
183.3/175.4A
193.8
215.3
207.5
230.6
221.2
245.8
248.9
276.6
276.6
307.3
304.3
338.1
DC Injec�on Current(mA)
Grid Frequency Range
Max.Efficiency
Euro Efficiency
>99%
MPPT Efficiency
Efficiency
General Data
Output Power Factor
<0.5%
47-52 or 57-62
(
op�onal
)
98.8%
98.7%
98.3%
0.8 leading to 0.8 lagging
<3%
Grid Current THD
838×568×324
838×568×346
Transformerless
Size(mm, W×H×D)
81
Weight(kg)
Topology
<1W(Night)
Internal consump�on
Opera�ng temperature
Ingress protec�on
IP65
<55dB
Smart cooling
Max. opera�on al�tude
Cooling Concept
Noise Emission(Typical)
2000m
Grid Connec�on Standard
Opera�on surrounding humidity
0~100%
Safety EMC / Standard
-25 ~ 65
℃
,>45
℃
dera�ng
IEC/EN 62109-1,IEC/EN 62109-2,
IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4
CEI 0-21,VDE-AR-N 4105,NRS 097,IEC 62116,IEC 61727,G99,G98,VDE 0126-1-1,RD 1699,C10-11
0
MAX inverter backfeed current (A)
Maximum output fault
current (a.c. A, peak )
Maximum output overcurrent
protec�on (a.c. A,peak)
60+60+60+60+60+60
40+40+40+40+40+40
6/4
>20 Years
Designed Life�me